메뉴 건너뛰기




Volumn 72, Issue 2, 2009, Pages 231-237

Dual energy subtraction: Principles and clinical applications

Author keywords

Calcification; Chest radiography; Energy subtraction; Nodule

Indexed keywords

CHEST RADIOGRAPHY; CLINICAL APPLICATION; CLINICAL SITUATIONS; DUAL-ENERGY SUBTRACTION; ENERGY SUBTRACTION; TECHNICAL SOLUTIONS;

EID: 71849093796     PISSN: 0720048X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ejrad.2009.03.046     Document Type: Review
Times cited : (63)

References (15)
  • 2
    • 32544454191 scopus 로고    scopus 로고
    • Dual-energy subtraction chest radiography: what to look for beyond calcified nodules
    • Kuhlman J.E., Collins J., Brooks G.N., Yandow D.R., and Broderick L.S. Dual-energy subtraction chest radiography: what to look for beyond calcified nodules. Radiographics 26 (2006) 79-92
    • (2006) Radiographics , vol.26 , pp. 79-92
    • Kuhlman, J.E.1    Collins, J.2    Brooks, G.N.3    Yandow, D.R.4    Broderick, L.S.5
  • 3
    • 54049108904 scopus 로고    scopus 로고
    • Dual energy subtraction and temporal subtraction chest radiography
    • MacMahon H., Li F., Engelmann R., Roberts R., and Armato S. Dual energy subtraction and temporal subtraction chest radiography. J Thorac Imaging 23 2 (2008) 77-85
    • (2008) J Thorac Imaging , vol.23 , Issue.2 , pp. 77-85
    • MacMahon, H.1    Li, F.2    Engelmann, R.3    Roberts, R.4    Armato, S.5
  • 4
    • 0037700163 scopus 로고    scopus 로고
    • Subtle lung nodules: influence of local anatomic variations on detection
    • Samei E., Flynn M.J., Peterson E., and William R.E. Subtle lung nodules: influence of local anatomic variations on detection. Radiology 228 (2003) 76-84
    • (2003) Radiology , vol.228 , pp. 76-84
    • Samei, E.1    Flynn, M.J.2    Peterson, E.3    William, R.E.4
  • 5
    • 0026513806 scopus 로고
    • Missed bronchogenic carcinoma: radiographic findings in 27 patients with potentially resectable lesion evident in retrospect
    • Austin J.H.M., Romney B.M., and Goldsmith L.S. Missed bronchogenic carcinoma: radiographic findings in 27 patients with potentially resectable lesion evident in retrospect. Radiology 182 (1992) 115-122
    • (1992) Radiology , vol.182 , pp. 115-122
    • Austin, J.H.M.1    Romney, B.M.2    Goldsmith, L.S.3
  • 6
    • 34548105734 scopus 로고    scopus 로고
    • Detection of lung cancer using single-exposure dual-energy subtraction chest radiography
    • Ide K., Mogami H., Murakami T., Yasuhara Y., Miyagawa M., and Mochizuki T. Detection of lung cancer using single-exposure dual-energy subtraction chest radiography. Radiat Med 25 5 (2007) 195-201
    • (2007) Radiat Med , vol.25 , Issue.5 , pp. 195-201
    • Ide, K.1    Mogami, H.2    Murakami, T.3    Yasuhara, Y.4    Miyagawa, M.5    Mochizuki, T.6
  • 7
    • 0023878862 scopus 로고
    • One-shot dual-energy subtraction chest imaging with computed radiography: clinical evaluation of film images
    • Ishigaki T., Sakuma S., and Ikeda M. One-shot dual-energy subtraction chest imaging with computed radiography: clinical evaluation of film images. Radiology 168 (1988) 67-72
    • (1988) Radiology , vol.168 , pp. 67-72
    • Ishigaki, T.1    Sakuma, S.2    Ikeda, M.3
  • 8
    • 0027818080 scopus 로고
    • Single-exposure dual-energy chest images with computed radiography. Evaluation with simulated pulmonary nodules
    • Kido S., Ikezoe J., Naito H., et al. Single-exposure dual-energy chest images with computed radiography. Evaluation with simulated pulmonary nodules. Invest Radiol 28 6 (1993) 482-487
    • (1993) Invest Radiol , vol.28 , Issue.6 , pp. 482-487
    • Kido, S.1    Ikezoe, J.2    Naito, H.3
  • 9
    • 0036894161 scopus 로고    scopus 로고
    • Computerized detection of pulmonary nodules by single-exposure dual-energy computed radiography of the chest (part 1)
    • Kido S., Nakamura H., Ito W., Shimura K., and Kato H. Computerized detection of pulmonary nodules by single-exposure dual-energy computed radiography of the chest (part 1). Eur J Radiol 44 3 (2002) 198-204
    • (2002) Eur J Radiol , vol.44 , Issue.3 , pp. 198-204
    • Kido, S.1    Nakamura, H.2    Ito, W.3    Shimura, K.4    Kato, H.5
  • 10
    • 42449094886 scopus 로고    scopus 로고
    • Improved detection of small lung cancers with dual-energy subtraction chest radiography
    • Li F., Engelmann R., Doi K., and MacMahon H. Improved detection of small lung cancers with dual-energy subtraction chest radiography. AJR 90 (2008) 886-891
    • (2008) AJR , vol.90 , pp. 886-891
    • Li, F.1    Engelmann, R.2    Doi, K.3    MacMahon, H.4
  • 11
    • 0022477270 scopus 로고
    • Simulated pulmonary nodules: detection with dual-energy digital versus conventional radiography
    • Niklason L.T., Hickey N.M., Chakraborty D.P., et al. Simulated pulmonary nodules: detection with dual-energy digital versus conventional radiography. Radiology 160 (1986) 589-593
    • (1986) Radiology , vol.160 , pp. 589-593
    • Niklason, L.T.1    Hickey, N.M.2    Chakraborty, D.P.3
  • 12
    • 0347531752 scopus 로고    scopus 로고
    • Clinical results of Csl-detector-based dual-exposure dual energy in chest radiography
    • Ricke J., Fischbach F., Freund T., et al. Clinical results of Csl-detector-based dual-exposure dual energy in chest radiography. Eur Radiol 13 12 (2003) 2577-2582
    • (2003) Eur Radiol , vol.13 , Issue.12 , pp. 2577-2582
    • Ricke, J.1    Fischbach, F.2    Freund, T.3
  • 13
    • 38949108969 scopus 로고    scopus 로고
    • Single-exposure dual-energy subtraction chest radiography: detection of pulmonary nodules and masses in clinical practice
    • Szucs-Farkas Z., Patak M.A., Yuksel-Hatz S., et al. Single-exposure dual-energy subtraction chest radiography: detection of pulmonary nodules and masses in clinical practice. Eur Radiol 18 (2008) 24-31
    • (2008) Eur Radiol , vol.18 , pp. 24-31
    • Szucs-Farkas, Z.1    Patak, M.A.2    Yuksel-Hatz, S.3
  • 14
    • 26644439790 scopus 로고    scopus 로고
    • Clinical evaluation of pulmonary nodules with dual-exposure dual-energy subtraction chest radiography
    • Uemura M., Miyagawa M., Yasuhara Y., et al. Clinical evaluation of pulmonary nodules with dual-exposure dual-energy subtraction chest radiography. Radiat Med 23 6 (2005) 391-397
    • (2005) Radiat Med , vol.23 , Issue.6 , pp. 391-397
    • Uemura, M.1    Miyagawa, M.2    Yasuhara, Y.3
  • 15
    • 33751192464 scopus 로고    scopus 로고
    • Dual energy subtraction digital radiography: technical considerations, clinical applications, and imaging pitfalls
    • Gilkeson R.C., and Sachs P.B. Dual energy subtraction digital radiography: technical considerations, clinical applications, and imaging pitfalls. J Thorac Imaging 21 4 (2006) 303-313
    • (2006) J Thorac Imaging , vol.21 , Issue.4 , pp. 303-313
    • Gilkeson, R.C.1    Sachs, P.B.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.