메뉴 건너뛰기




Volumn 136, Issue 5, 2009, Pages 700-707

Loss of anchorage of miniscrews: A 3-dimensional assessment

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; BONE REGENERATION; BONE SCREW; CEPHALOMETRY; DENTAL SURGERY; HUMAN; INSTRUMENTATION; LONGITUDINAL STUDY; MALOCCLUSION; MANDIBLE; MAXILLA; METHODOLOGY; ORTHODONTICS; PERIODONTAL DISEASE; THREE DIMENSIONAL IMAGING; TIME; TOOTH IMPLANTATION;

EID: 71849087267     PISSN: 08895406     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ajodo.2007.10.059     Document Type: Article
Times cited : (59)

References (46)
  • 1
    • 7544245529 scopus 로고    scopus 로고
    • Treatment of open bite with microscrew implant anchorage
    • Park H.S., Kwon T.G., and Kwon O.H. Treatment of open bite with microscrew implant anchorage. Am J Orthod Dentofacial Orthop 126 (2004) 627-636
    • (2004) Am J Orthod Dentofacial Orthop , vol.126 , pp. 627-636
    • Park, H.S.1    Kwon, T.G.2    Kwon, O.H.3
  • 2
    • 4444308807 scopus 로고    scopus 로고
    • Severe anterior openbite case treated using titanium screw anchorage
    • Kuroda S., Katayama A., and Yamamoto T.T. Severe anterior openbite case treated using titanium screw anchorage. Angle Orthod 74 (2004) 558-567
    • (2004) Angle Orthod , vol.74 , pp. 558-567
    • Kuroda, S.1    Katayama, A.2    Yamamoto, T.T.3
  • 3
    • 33748456704 scopus 로고    scopus 로고
    • Nonextraction treatment of an open bite with microscrew implant anchorage
    • Park H.S., Kwon O.W., and Sung J.H. Nonextraction treatment of an open bite with microscrew implant anchorage. Am J Orthod Dentofacial Orthop 130 (2006) 391-402
    • (2006) Am J Orthod Dentofacial Orthop , vol.130 , pp. 391-402
    • Park, H.S.1    Kwon, O.W.2    Sung, J.H.3
  • 4
    • 33846048891 scopus 로고    scopus 로고
    • Microscrew anchorage in skeletal anterior open-bite treatment
    • Xun C., Zeng X., and Wang X. Microscrew anchorage in skeletal anterior open-bite treatment. Angle Orthod 77 (2006) 47-56
    • (2006) Angle Orthod , vol.77 , pp. 47-56
    • Xun, C.1    Zeng, X.2    Wang, X.3
  • 5
    • 18244387213 scopus 로고    scopus 로고
    • A mini-implant for orthodontic anchorage in a deep overbite case
    • Ohnishi H., Yagib T., Yasuda Y., and Takadad K. A mini-implant for orthodontic anchorage in a deep overbite case. Angle Orthod 75 (2005) 444-452
    • (2005) Angle Orthod , vol.75 , pp. 444-452
    • Ohnishi, H.1    Yagib, T.2    Yasuda, Y.3    Takadad, K.4
  • 6
    • 0035492033 scopus 로고    scopus 로고
    • Micro-implant anchorage for lingual treatment of a skeletal Class II malocclusion
    • Lee J.S., Park H.S., and Kyung H.M. Micro-implant anchorage for lingual treatment of a skeletal Class II malocclusion. J Clin Orthod 35 (2001) 643-647
    • (2001) J Clin Orthod , vol.35 , pp. 643-647
    • Lee, J.S.1    Park, H.S.2    Kyung, H.M.3
  • 7
    • 33846075297 scopus 로고    scopus 로고
    • Unusual extraction treatment in Class II Division 1 using c-orthodontic mini-implants
    • Chung K.R., Cho J.H., Kim S.H., Kook Y.A., and Cozzani M. Unusual extraction treatment in Class II Division 1 using c-orthodontic mini-implants. Angle Orthod 77 (2007) 387-392
    • (2007) Angle Orthod , vol.77 , pp. 387-392
    • Chung, K.R.1    Cho, J.H.2    Kim, S.H.3    Kook, Y.A.4    Cozzani, M.5
  • 8
    • 13244268399 scopus 로고    scopus 로고
    • C-orthodontic microimplant for distalization of mandibular dentition in Class III correction
    • Chung K., Kim S.H., and Kook Y. C-orthodontic microimplant for distalization of mandibular dentition in Class III correction. Angle Orthod 75 (2004) 119-128
    • (2004) Angle Orthod , vol.75 , pp. 119-128
    • Chung, K.1    Kim, S.H.2    Kook, Y.3
  • 9
    • 33646037315 scopus 로고    scopus 로고
    • Comparison and measurement of the amount of anchorage loss of the molars with and without the use of implant anchorage during canine retraction
    • Thiruvenkatachari B., Pavithranand A., Rajasigamani K., and Kyung H.M. Comparison and measurement of the amount of anchorage loss of the molars with and without the use of implant anchorage during canine retraction. Am J Orthod Dentofacial Orthop 129 (2006) 551-554
    • (2006) Am J Orthod Dentofacial Orthop , vol.129 , pp. 551-554
    • Thiruvenkatachari, B.1    Pavithranand, A.2    Rajasigamani, K.3    Kyung, H.M.4
  • 10
    • 33746792428 scopus 로고    scopus 로고
    • Mini-implant anchorage for maxillary canine retraction: a pilot study
    • Herman R., Currier G.F., and Miyake A. Mini-implant anchorage for maxillary canine retraction: a pilot study. Am J Orthod Dentofacial Orthop 130 (2006) 228-235
    • (2006) Am J Orthod Dentofacial Orthop , vol.130 , pp. 228-235
    • Herman, R.1    Currier, G.F.2    Miyake, A.3
  • 12
    • 4444257684 scopus 로고    scopus 로고
    • Intrusion of the overerupted upper left first and second molars by mini-implants with partial-fixed orthodontic appliances: a case report
    • Yao C.C.J., Wu C.B., Wu H.Y., Kok S.H., Chang H.F.F., and Chen Y.J. Intrusion of the overerupted upper left first and second molars by mini-implants with partial-fixed orthodontic appliances: a case report. Angle Orthod 74 (2004) 550-557
    • (2004) Angle Orthod , vol.74 , pp. 550-557
    • Yao, C.C.J.1    Wu, C.B.2    Wu, H.Y.3    Kok, S.H.4    Chang, H.F.F.5    Chen, Y.J.6
  • 14
    • 24744443951 scopus 로고    scopus 로고
    • Maxillary molar intrusion with fixed appliances and mini-implant anchorage studied in three dimensions
    • Yao C.C.J., Lee J.J., Chen H.Y., Chang Z.C.J., Chang H.F., and Chen Y.J. Maxillary molar intrusion with fixed appliances and mini-implant anchorage studied in three dimensions. Angle Orthod 75 (2005) 754-760
    • (2005) Angle Orthod , vol.75 , pp. 754-760
    • Yao, C.C.J.1    Lee, J.J.2    Chen, H.Y.3    Chang, Z.C.J.4    Chang, H.F.5    Chen, Y.J.6
  • 15
    • 0035407943 scopus 로고    scopus 로고
    • Micro-implant anchorage for treatment of skeletal Class I bialveolar protrusion
    • Park H.S., Bae S.M., Kyung H.M., and Sung J.H. Micro-implant anchorage for treatment of skeletal Class I bialveolar protrusion. J Clin Orthod 35 (2001) 417-422
    • (2001) J Clin Orthod , vol.35 , pp. 417-422
    • Park, H.S.1    Bae, S.M.2    Kyung, H.M.3    Sung, J.H.4
  • 16
    • 7044264818 scopus 로고    scopus 로고
    • Sliding mechanics with microscrew implant anchorage
    • Park H.S., and Kwon T.G. Sliding mechanics with microscrew implant anchorage. Angle Orthod 74 (2004) 703-710
    • (2004) Angle Orthod , vol.74 , pp. 703-710
    • Park, H.S.1    Kwon, T.G.2
  • 17
    • 7044235077 scopus 로고    scopus 로고
    • Screw-type implants used as anchorage for lingual orthodontic mechanics: a case of bimaxillary protrusion with second premolar extraction
    • Kawakami M., Miyawaki S., Noguchi H., and Kirita T. Screw-type implants used as anchorage for lingual orthodontic mechanics: a case of bimaxillary protrusion with second premolar extraction. Angle Orthod 74 (2004) 715-719
    • (2004) Angle Orthod , vol.74 , pp. 715-719
    • Kawakami, M.1    Miyawaki, S.2    Noguchi, H.3    Kirita, T.4
  • 18
    • 4444249537 scopus 로고    scopus 로고
    • Nonextraction treatment with microscrew implants
    • Park H.S., Kwon T.G., and Sung J.H. Nonextraction treatment with microscrew implants. Angle Orthod 74 (2004) 539-549
    • (2004) Angle Orthod , vol.74 , pp. 539-549
    • Park, H.S.1    Kwon, T.G.2    Sung, J.H.3
  • 19
    • 21644433269 scopus 로고    scopus 로고
    • Group distal movement of teeth using microscrew implant anchorage
    • Park H.S., Lee S.K., and Kwon O.W. Group distal movement of teeth using microscrew implant anchorage. Angle Orthod 75 (2005) 602-609
    • (2005) Angle Orthod , vol.75 , pp. 602-609
    • Park, H.S.1    Lee, S.K.2    Kwon, O.W.3
  • 20
    • 31144468795 scopus 로고    scopus 로고
    • Pektaş ZO, Uçkan S. Orthopedic protraction with skeletal anchorage in a patient with maxillary hypoplasia and hypodontia
    • Kircelli B.H. Pektaş ZO, Uçkan S. Orthopedic protraction with skeletal anchorage in a patient with maxillary hypoplasia and hypodontia. Angle Orthod 76 (2006) 156-163
    • (2006) Angle Orthod , vol.76 , pp. 156-163
    • Kircelli, B.H.1
  • 21
    • 71849085685 scopus 로고    scopus 로고
    • Do miniscrews remain stationary under orthodontic forces?
    • Liou E.J., Pai B.C., and Lin J.C. Do miniscrews remain stationary under orthodontic forces?. Am J Orthod Dentofacial Orthop 124 (2003) 373-378
    • (2003) Am J Orthod Dentofacial Orthop , vol.124 , pp. 373-378
    • Liou, E.J.1    Pai, B.C.2    Lin, J.C.3
  • 23
    • 33745835122 scopus 로고    scopus 로고
    • Factors affecting the clinical success of screw implants used as orthodontic anchorage
    • Park H.S., Jeong S.H., and Kwon O.W. Factors affecting the clinical success of screw implants used as orthodontic anchorage. Am J Orthod Dentofacial Orthop 130 (2006) 18-25
    • (2006) Am J Orthod Dentofacial Orthop , vol.130 , pp. 18-25
    • Park, H.S.1    Jeong, S.H.2    Kwon, O.W.3
  • 24
    • 14544303622 scopus 로고    scopus 로고
    • Miniscrew implants: IMTEC mini ortho implants
    • Herman R., and Cope J.B. Miniscrew implants: IMTEC mini ortho implants. Semin Orthod 11 (2005) 32-39
    • (2005) Semin Orthod , vol.11 , pp. 32-39
    • Herman, R.1    Cope, J.B.2
  • 26
    • 13244284696 scopus 로고    scopus 로고
    • Lever-arm and mini-implant system for anterior torque control during retraction in lingual orthodontic treatment
    • Hong R.K., Heo J.M., and Ha Y.K. Lever-arm and mini-implant system for anterior torque control during retraction in lingual orthodontic treatment. Angle Orthod 75 (2004) 129-141
    • (2004) Angle Orthod , vol.75 , pp. 129-141
    • Hong, R.K.1    Heo, J.M.2    Ha, Y.K.3
  • 27
    • 14544287285 scopus 로고    scopus 로고
    • Miniscrew implants: the Aarhus anchorage system
    • Melsen B., and Verna C. Miniscrew implants: the Aarhus anchorage system. Semin Orthod 11 (2005) 24-31
    • (2005) Semin Orthod , vol.11 , pp. 24-31
    • Melsen, B.1    Verna, C.2
  • 28
    • 0141921987 scopus 로고    scopus 로고
    • Factors associated with the stability of titanium screws placed in the posterior region for orthodontic anchorage
    • Miyawaki S., Koyama I., Inoue M., Mishima K., Sugahara T., and Yamamoto T.T. Factors associated with the stability of titanium screws placed in the posterior region for orthodontic anchorage. Am J Orthod Dentofacial Orthop 124 (2003) 373-378
    • (2003) Am J Orthod Dentofacial Orthop , vol.124 , pp. 373-378
    • Miyawaki, S.1    Koyama, I.2    Inoue, M.3    Mishima, K.4    Sugahara, T.5    Yamamoto, T.T.6
  • 29
    • 33746018652 scopus 로고    scopus 로고
    • Implants vs screw loading protocols in orthodontics. A systematic review
    • Ohashi E., Pecho O., Moron M., and Lagravere M. Implants vs screw loading protocols in orthodontics. A systematic review. Angle Orthod 76 (2006) 721-727
    • (2006) Angle Orthod , vol.76 , pp. 721-727
    • Ohashi, E.1    Pecho, O.2    Moron, M.3    Lagravere, M.4
  • 30
    • 0032052118 scopus 로고    scopus 로고
    • A histologic evaluation of eight cases of failed dental implants. Is bone overheating the most probable cause?
    • Piattelli A., Piattelli M., Mangano C., and Scarano A. A histologic evaluation of eight cases of failed dental implants. Is bone overheating the most probable cause?. Biomaterials 19 (1998) 683-690
    • (1998) Biomaterials , vol.19 , pp. 683-690
    • Piattelli, A.1    Piattelli, M.2    Mangano, C.3    Scarano, A.4
  • 31
    • 0035344075 scopus 로고    scopus 로고
    • A clinical and histological evaluation of titanium mini-implants as anchors for orthodontic intrusion in the beagle dog
    • Ohmae M., Saito S., Morohashi T., Seki K., Qu H., Kanomi R., et al. A clinical and histological evaluation of titanium mini-implants as anchors for orthodontic intrusion in the beagle dog. Am J Orthod Dentofacial Orthop 119 (2001) 489-497
    • (2001) Am J Orthod Dentofacial Orthop , vol.119 , pp. 489-497
    • Ohmae, M.1    Saito, S.2    Morohashi, T.3    Seki, K.4    Qu, H.5    Kanomi, R.6
  • 32
    • 33646168325 scopus 로고    scopus 로고
    • Plane orientation for standardization in 3-dimensional cephalometric analysis with computerized tomography imaging
    • Lagravere M.O., Hansen L., Harzer W., and Major P.W. Plane orientation for standardization in 3-dimensional cephalometric analysis with computerized tomography imaging. Am J Orthod Dentofacial Orthop 129 (2006) 601-604
    • (2006) Am J Orthod Dentofacial Orthop , vol.129 , pp. 601-604
    • Lagravere, M.O.1    Hansen, L.2    Harzer, W.3    Major, P.W.4
  • 33
    • 33646166175 scopus 로고    scopus 로고
    • Image analysis and superimposition of 3-dimensional cone-beam computed tomography models
    • Cevidanes L.H.S., Styner M.A., and Proffit W.R. Image analysis and superimposition of 3-dimensional cone-beam computed tomography models. Am J Orthod Dentofacial Orthop 129 (2006) 611-618
    • (2006) Am J Orthod Dentofacial Orthop , vol.129 , pp. 611-618
    • Cevidanes, L.H.S.1    Styner, M.A.2    Proffit, W.R.3
  • 34
    • 33745828695 scopus 로고    scopus 로고
    • Three-dimensional spiral computed tomographic imaging: a new approach to the diagnosis and treatment planning of impacted teeth
    • Chen Y., Duan P., Meng Y., and Chen Y. Three-dimensional spiral computed tomographic imaging: a new approach to the diagnosis and treatment planning of impacted teeth. Am J Orthod Dentofacial Orthop 130 (2006) 112-116
    • (2006) Am J Orthod Dentofacial Orthop , vol.130 , pp. 112-116
    • Chen, Y.1    Duan, P.2    Meng, Y.3    Chen, Y.4
  • 38
    • 33845863912 scopus 로고    scopus 로고
    • Clinical use of miniscrew implants as orthodontic anchorage: success rates and postoperative discomfort
    • Kuroda S., Sugawara Y., Deguchi T., Kyung H.M., and Yamamoto T.T. Clinical use of miniscrew implants as orthodontic anchorage: success rates and postoperative discomfort. Am J Orthod Dentofacial Orthop 131 (2007) 9-15
    • (2007) Am J Orthod Dentofacial Orthop , vol.131 , pp. 9-15
    • Kuroda, S.1    Sugawara, Y.2    Deguchi, T.3    Kyung, H.M.4    Yamamoto, T.T.5
  • 39
    • 34247167529 scopus 로고    scopus 로고
    • Risks and complications of orthodontic miniscrews
    • Kravitz N.D., and Kusnoto B. Risks and complications of orthodontic miniscrews. Am J Orthod Dentofacial Orthop 131 Suppl (2007) S43-S51
    • (2007) Am J Orthod Dentofacial Orthop , vol.131 , Issue.SUPPL
    • Kravitz, N.D.1    Kusnoto, B.2
  • 41
    • 0022759220 scopus 로고
    • The effect of projection error on cephalometric length measurements
    • Ahlqvist J., Eliasson J., and Welander U. The effect of projection error on cephalometric length measurements. Eur J Orthod 8 (1986) 141-148
    • (1986) Eur J Orthod , vol.8 , pp. 141-148
    • Ahlqvist, J.1    Eliasson, J.2    Welander, U.3
  • 42
    • 0024153053 scopus 로고
    • The effect of projection error on angular measurements in cephalometry
    • Ahlqvist J., Eliasson J., and Welander U. The effect of projection error on angular measurements in cephalometry. Eur J Orthod 10 (1988) 353-361
    • (1988) Eur J Orthod , vol.10 , pp. 353-361
    • Ahlqvist, J.1    Eliasson, J.2    Welander, U.3
  • 43
    • 0034305346 scopus 로고    scopus 로고
    • Comparison of landmark identification in traditional versus computer-aided digital cephalometry
    • Chen Y., Chen S., Chang H., and Chen K. Comparison of landmark identification in traditional versus computer-aided digital cephalometry. Angle Orthod 70 (2000) 387-392
    • (2000) Angle Orthod , vol.70 , pp. 387-392
    • Chen, Y.1    Chen, S.2    Chang, H.3    Chen, K.4
  • 44
    • 0029684607 scopus 로고    scopus 로고
    • Digital imaging of cephalometric radiography, part 1: advantages and limitations of digital imaging
    • Forsyth D.B., Shaw W.C., and Richmond S. Digital imaging of cephalometric radiography, part 1: advantages and limitations of digital imaging. Angle Orthod 66 (1996) 37-42
    • (1996) Angle Orthod , vol.66 , pp. 37-42
    • Forsyth, D.B.1    Shaw, W.C.2    Richmond, S.3
  • 45
    • 0029690353 scopus 로고    scopus 로고
    • Digital imaging of cephalometric radiography, part 2: image quality
    • Forsyth D.B., Shaw W.C., Richmond S., and Roberts C.J. Digital imaging of cephalometric radiography, part 2: image quality. Angle Orthod 66 (1996) 43-50
    • (1996) Angle Orthod , vol.66 , pp. 43-50
    • Forsyth, D.B.1    Shaw, W.C.2    Richmond, S.3    Roberts, C.J.4
  • 46
    • 0031989176 scopus 로고    scopus 로고
    • Automatic computerized radiographic identification of cephalometric landmarks
    • Rudolph D., Sinclair P., and Coggins J. Automatic computerized radiographic identification of cephalometric landmarks. Am J Orthod Dentofacial Orthop 113 (1998) 173-179
    • (1998) Am J Orthod Dentofacial Orthop , vol.113 , pp. 173-179
    • Rudolph, D.1    Sinclair, P.2    Coggins, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.