메뉴 건너뛰기




Volumn 143, Issue 1, 2009, Pages 144-151

A novel method for monitoring mass-change response of piezoelectric-excited millimeter-sized cantilever (PEMC) sensors

Author keywords

Biosensor; Density; E. coli O157:H7 detection; Impedance; Resonant cantilever

Indexed keywords

BIOSENSING; CONVENTIONAL APPROACH; DENSITY CHANGE; E. COLI O157:H7 DETECTION; E.COLI O157:H7; EQUIVALENT MEASUREMENT; FIXED FREQUENCY; HIGH THROUGHPUT; LINEAR FUNCTIONS; NOVEL METHODS; Q-VALUES; RESONANT CANTILEVER; RESONANT FREQUENCIES; SENSOR RESPONSE;

EID: 71849085528     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2009.08.045     Document Type: Article
Times cited : (16)

References (29)
  • 1
    • 48249150392 scopus 로고    scopus 로고
    • Cantilever biosensors
    • Fritz J. Cantilever biosensors. Analyst 133 (2008) 855-863
    • (2008) Analyst , vol.133 , pp. 855-863
    • Fritz, J.1
  • 2
    • 40449138983 scopus 로고    scopus 로고
    • Microcantilevers: sensing chemical interactions via mechanical motion
    • Goeders K.M., Colton J.S., and Bottomley L.A. Microcantilevers: sensing chemical interactions via mechanical motion. Chem. Rev. 108 (2008) 522-542
    • (2008) Chem. Rev. , vol.108 , pp. 522-542
    • Goeders, K.M.1    Colton, J.S.2    Bottomley, L.A.3
  • 3
    • 34748835764 scopus 로고    scopus 로고
    • Micro- and nanomechanical sensors for environmental, chemical, and biological detection
    • Waggoner P.S., and Craighead H.G. Micro- and nanomechanical sensors for environmental, chemical, and biological detection. Lab Chip 7 (2007) 1238-1255
    • (2007) Lab Chip , vol.7 , pp. 1238-1255
    • Waggoner, P.S.1    Craighead, H.G.2
  • 4
    • 1842788500 scopus 로고    scopus 로고
    • Single virus particle mass detection using microresonators with nanoscale thickness
    • Gupta A., Akin D., and Bashir R. Single virus particle mass detection using microresonators with nanoscale thickness. Appl. Phys. Lett. 84 (2004) 1976-1978
    • (2004) Appl. Phys. Lett. , vol.84 , pp. 1976-1978
    • Gupta, A.1    Akin, D.2    Bashir, R.3
  • 5
    • 7544230375 scopus 로고    scopus 로고
    • Virus detection using nanoelectromechanical devices
    • Ilic B., Yang Y., and Craighead H.G. Virus detection using nanoelectromechanical devices. Appl. Phys. Lett. 85 (2004) 2604-2606
    • (2004) Appl. Phys. Lett. , vol.85 , pp. 2604-2606
    • Ilic, B.1    Yang, Y.2    Craighead, H.G.3
  • 6
    • 11744318388 scopus 로고
    • Measurement of interfacial processes at electrode surfaces with the electrochemical quartz crystal microbalance
    • Buttry D.A., and Ward M.D. Measurement of interfacial processes at electrode surfaces with the electrochemical quartz crystal microbalance. Chem. Rev. 92 (1992) 1355-1379
    • (1992) Chem. Rev. , vol.92 , pp. 1355-1379
    • Buttry, D.A.1    Ward, M.D.2
  • 7
    • 0034680544 scopus 로고    scopus 로고
    • Piezoelectric mass-sensing devices as biosensors-an alternative to optical biosensors?
    • Janshoff A., Galla H.J., and Steinem C. Piezoelectric mass-sensing devices as biosensors-an alternative to optical biosensors?. Angew. Chem.-Int. Ed. 39 (2000) 4004-4032
    • (2000) Angew. Chem.-Int. Ed. , vol.39 , pp. 4004-4032
    • Janshoff, A.1    Galla, H.J.2    Steinem, C.3
  • 8
    • 0037210272 scopus 로고    scopus 로고
    • Impedance characterization of a piezoelectric immunosensor. Part I: antibody coating and buffer solution
    • Kim G.H., Rand A.G., and Letcher S.V. Impedance characterization of a piezoelectric immunosensor. Part I: antibody coating and buffer solution. Biosens. Bioelectron. 18 (2003) 83-89
    • (2003) Biosens. Bioelectron. , vol.18 , pp. 83-89
    • Kim, G.H.1    Rand, A.G.2    Letcher, S.V.3
  • 9
    • 0037210358 scopus 로고    scopus 로고
    • Impedance characterization of a piezoelectric immunosensor part II: Salmonella typhimurium detection using magnetic enhancement
    • Kim G.-H., Rand A.G., and Letcher S.V. Impedance characterization of a piezoelectric immunosensor part II: Salmonella typhimurium detection using magnetic enhancement. Biosens. Bioelectron. 18 (2003) 91-99
    • (2003) Biosens. Bioelectron. , vol.18 , pp. 91-99
    • Kim, G.-H.1    Rand, A.G.2    Letcher, S.V.3
  • 10
    • 27444436698 scopus 로고    scopus 로고
    • A QCM immunosensor for Salmonella detection with simultaneous measurements of resonant frequency and motional resistance
    • Su X.-L., and Li Y. A QCM immunosensor for Salmonella detection with simultaneous measurements of resonant frequency and motional resistance. Biosens. Bioelectron. 21 (2005) 840-848
    • (2005) Biosens. Bioelectron. , vol.21 , pp. 840-848
    • Su, X.-L.1    Li, Y.2
  • 11
    • 0032706837 scopus 로고    scopus 로고
    • A study of depletion layer effects on equivalent circuit parameters using an electrochemical quartz crystal impedance system
    • Xie Q.J., Wang J., Zhou A.H., Zhang Y.Y., Liu H.W., Xu Z.N., Yuan Y., Deng M.Y., and Yao S.Z. A study of depletion layer effects on equivalent circuit parameters using an electrochemical quartz crystal impedance system. Anal. Chem. 71 (1999) 4649-4656
    • (1999) Anal. Chem. , vol.71 , pp. 4649-4656
    • Xie, Q.J.1    Wang, J.2    Zhou, A.H.3    Zhang, Y.Y.4    Liu, H.W.5    Xu, Z.N.6    Yuan, Y.7    Deng, M.Y.8    Yao, S.Z.9
  • 12
    • 25444497224 scopus 로고    scopus 로고
    • Simultaneous impedance measurements of two one-face sealed resonating piezoelectric quartz crystals for in situ monitoring of electrochemical processes and solution properties
    • Xie Q.J., Xiang C.H., Yang X.H., Zhang Y.Y., Li M., and Yao S.Z. Simultaneous impedance measurements of two one-face sealed resonating piezoelectric quartz crystals for in situ monitoring of electrochemical processes and solution properties. Anal. Chim. Acta 533 (2005) 213-224
    • (2005) Anal. Chim. Acta , vol.533 , pp. 213-224
    • Xie, Q.J.1    Xiang, C.H.2    Yang, X.H.3    Zhang, Y.Y.4    Li, M.5    Yao, S.Z.6
  • 13
    • 0034045376 scopus 로고    scopus 로고
    • Analysis of the composite response of shear wave resonators to the attachment of mammalian cells
    • Wegener J., Seebach J., Janshoff A., and Galla H.-J. Analysis of the composite response of shear wave resonators to the attachment of mammalian cells. Biophys. J. 78 (2000) 2821-2833
    • (2000) Biophys. J. , vol.78 , pp. 2821-2833
    • Wegener, J.1    Seebach, J.2    Janshoff, A.3    Galla, H.-J.4
  • 14
    • 34248190853 scopus 로고    scopus 로고
    • Monitoring cell adhesion by piezoresonators: impact of increasing oscillation amplitudes
    • Heitmann V., and Wegener J. Monitoring cell adhesion by piezoresonators: impact of increasing oscillation amplitudes. Anal. Chem. 79 (2007) 3392-3400
    • (2007) Anal. Chem. , vol.79 , pp. 3392-3400
    • Heitmann, V.1    Wegener, J.2
  • 15
    • 34248578217 scopus 로고    scopus 로고
    • Piezoelectric-excited millimeter-sized cantilever sensors detect density differences of a few micrograms/mL in liquid medium
    • Rijal K., and Mutharasan R. Piezoelectric-excited millimeter-sized cantilever sensors detect density differences of a few micrograms/mL in liquid medium. Sens. Actuators B: Chem. 124 (2007) 237-244
    • (2007) Sens. Actuators B: Chem. , vol.124 , pp. 237-244
    • Rijal, K.1    Mutharasan, R.2
  • 16
    • 0032109073 scopus 로고    scopus 로고
    • Frequency response of cantilever beams immersed in viscous fluids with applications to the atomic force microscope
    • Sader J.E. Frequency response of cantilever beams immersed in viscous fluids with applications to the atomic force microscope. J. Appl. Phys. 84 (1998) 64-76
    • (1998) J. Appl. Phys. , vol.84 , pp. 64-76
    • Sader, J.E.1
  • 17
    • 34447558536 scopus 로고    scopus 로고
    • 10-minute assay for detecting Escherichia coli O157: H7 in ground beef samples using piezoelectric-excited millimeter-size cantilever sensors
    • Maraldo D., and Mutharasan R. 10-minute assay for detecting Escherichia coli O157: H7 in ground beef samples using piezoelectric-excited millimeter-size cantilever sensors. J. Food Prot. 70 (2007) 1670-1677
    • (2007) J. Food Prot. , vol.70 , pp. 1670-1677
    • Maraldo, D.1    Mutharasan, R.2
  • 18
    • 34247120167 scopus 로고    scopus 로고
    • Method for label-free detection of femtogram quantities of biologics in flowing liquid samples
    • Maraldo D., Rijal K., Campbell G., and Mutharasan R. Method for label-free detection of femtogram quantities of biologics in flowing liquid samples. Anal. Chem. 79 (2007) 2762-2770
    • (2007) Anal. Chem. , vol.79 , pp. 2762-2770
    • Maraldo, D.1    Rijal, K.2    Campbell, G.3    Mutharasan, R.4
  • 19
    • 36048950726 scopus 로고    scopus 로고
    • Preparation-free method for detecting Escherichia coli O157: H7 in the presence of spinach, spring lettuce mix, and ground beef particulates
    • Maraldo D., and Mutharasan R. Preparation-free method for detecting Escherichia coli O157: H7 in the presence of spinach, spring lettuce mix, and ground beef particulates. J. Food Prot. 70 (2007) 2651-2655
    • (2007) J. Food Prot. , vol.70 , pp. 2651-2655
    • Maraldo, D.1    Mutharasan, R.2
  • 20
    • 71849109242 scopus 로고    scopus 로고
    • accessed April 1, 2009
    • http://www.cdc.gov/ecoli/, accessed April 1, 2009.
  • 21
    • 35448959959 scopus 로고    scopus 로고
    • Detection and confirmation of staphylococcal enterotoxin B in apple juice and milk using piezoelectric-excited millimeter-sized cantilever sensors at 2.5 fg/mL
    • Maraldo D., and Mutharasan R. Detection and confirmation of staphylococcal enterotoxin B in apple juice and milk using piezoelectric-excited millimeter-sized cantilever sensors at 2.5 fg/mL. Anal. Chem. 79 (2007) 7636-7643
    • (2007) Anal. Chem. , vol.79 , pp. 7636-7643
    • Maraldo, D.1    Mutharasan, R.2
  • 22
    • 35348982230 scopus 로고    scopus 로고
    • PEMC-based method of measuring DNA hybridization at femtomolar concentration directly in human serum and in the presence of copious noncomplementary strands
    • Rijal K., and Mutharasan R. PEMC-based method of measuring DNA hybridization at femtomolar concentration directly in human serum and in the presence of copious noncomplementary strands. Anal. Chem. 79 (2007) 7392-7400
    • (2007) Anal. Chem. , vol.79 , pp. 7392-7400
    • Rijal, K.1    Mutharasan, R.2
  • 23
    • 43749093020 scopus 로고    scopus 로고
    • Mass-change sensitivity of piezoelectric-excited millimeter-sized cantilever (PEMC) sensors: model and experiments
    • Maraldo D., and Mutharasan R. Mass-change sensitivity of piezoelectric-excited millimeter-sized cantilever (PEMC) sensors: model and experiments. Sens. Actuators B: Chem. 132 (2008) 140-148
    • (2008) Sens. Actuators B: Chem. , vol.132 , pp. 140-148
    • Maraldo, D.1    Mutharasan, R.2
  • 24
    • 71849115953 scopus 로고
    • Technical Report No. 2, DTMB, Contract NObs-86396X, Southwest Research Institute, San Antonio, Texas
    • W.-H. Chu, 1963, Technical Report No. 2, DTMB, Contract NObs-86396(X), Southwest Research Institute, San Antonio, Texas.
    • (1963)
    • Chu, W.-H.1
  • 25
    • 33746514451 scopus 로고    scopus 로고
    • Detection of Bacillus anthracis spores and a model protein using PEMC sensors in a flow cell at 1 mL/min
    • Campbell G.A., and Mutharasan R. Detection of Bacillus anthracis spores and a model protein using PEMC sensors in a flow cell at 1 mL/min. Biosens. Bioelectron. 22 (2006) 78-85
    • (2006) Biosens. Bioelectron. , vol.22 , pp. 78-85
    • Campbell, G.A.1    Mutharasan, R.2
  • 26
    • 34250671586 scopus 로고    scopus 로고
    • Method for measuring the self-assembly of alkanethiols on gold at femtomolar concentrations
    • Rijal K., and Mutharasan R. Method for measuring the self-assembly of alkanethiols on gold at femtomolar concentrations. Langmuir 23 (2007) 6856-6863
    • (2007) Langmuir , vol.23 , pp. 6856-6863
    • Rijal, K.1    Mutharasan, R.2
  • 27
    • 0037099288 scopus 로고    scopus 로고
    • Simultaneous quartz crystal microbalance impedance and electrochemical impedance measurements. Investigation into the degradation of thin polymer films
    • Sabot A., and Krause S. Simultaneous quartz crystal microbalance impedance and electrochemical impedance measurements. Investigation into the degradation of thin polymer films. Anal. Chem. 74 (2002) 3304-3311
    • (2002) Anal. Chem. , vol.74 , pp. 3304-3311
    • Sabot, A.1    Krause, S.2
  • 28
    • 25844490050 scopus 로고    scopus 로고
    • Detection and quantification of proteins using self-excited PZT-glass millimeter-sized cantilever
    • Campbell G.A., and Mutharasan R. Detection and quantification of proteins using self-excited PZT-glass millimeter-sized cantilever. Biosens. Bioelectron. 21 (2005) 597-607
    • (2005) Biosens. Bioelectron. , vol.21 , pp. 597-607
    • Campbell, G.A.1    Mutharasan, R.2
  • 29
    • 33846355681 scopus 로고    scopus 로고
    • Detect of Escherichia coli O157: H7 in ground beef samples using piezoelectric excited millimeter-sized cantilever (PEMC) sensors
    • Campbell G.A., Uknalis J., Tu S.I., and Mutharasan R. Detect of Escherichia coli O157: H7 in ground beef samples using piezoelectric excited millimeter-sized cantilever (PEMC) sensors. Biosens. Bioelectron. 22 (2007) 1296-1302
    • (2007) Biosens. Bioelectron. , vol.22 , pp. 1296-1302
    • Campbell, G.A.1    Uknalis, J.2    Tu, S.I.3    Mutharasan, R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.