Volumn 142, Issue 2, 2009, Pages 406-411

Characterization of viscoelastic properties of adsorbed biomolecules and biomolecular assemblies with high frequency micromachined quartz resonators

Author keywords

Avidin; Biotynilated bovine album; Micromachining quartz; QCM arrays; Quartz crystal microbalance; Viscoelastic loading

Indexed keywords

BIO-MOLECULAR; BIOTYNILATED BOVINE ALBUM; BOVINE ALBUMIN; COMPLEX IMPEDANCE; CROSSLINKER; DYNAMIC VISCOELASTIC PROPERTIES; FRICTIONAL EFFECTS; FUNDAMENTAL MODES; HIGH FREQUENCY; HIGH Q FACTOR; HIGH SENSITIVITY; INTER-LINKING; LINEAR DEPENDENCE; MASS LOADINGS; MATERIAL PROPERTY; MICRO RESONATORS; MICROMACHINED; MICROMACHINING QUARTZ; Q-FACTORS; QCM ARRAYS; QUARTZ CRYSTAL RESONATOR; QUARTZ RESONATORS; SEQUENTIAL ADSORPTION; SQUARE ROOTS; STATIC LOADING; VARIABLE VISCOSITY; VISCOELASTIC LAYERS; VISCOELASTIC PROPERTIES; WATER-GLYCEROL MIXTURES;

EID: 71749105136     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2009.01.046     Document Type: Article
Times cited : (10)

References (20)
  • 1
    • 0032704734 scopus 로고    scopus 로고
    • Commercial quartz crystal microbalances-theory and applications
    • O'Sullivan C.K., and Guilbault G.G. Commercial quartz crystal microbalances-theory and applications. Biosens. Bioelectron. 14 8-9 (1999) 663-670
    • (1999) Biosens. Bioelectron. , vol.14 , Issue.8-9 , pp. 663-670
    • O'Sullivan, C.K.1    Guilbault, G.G.2
  • 2
    • 84951279351 scopus 로고
    • Verwendung von Schwingquarzen zur Wagung dunner Schichten und zur Mikrowagung
    • Sauerbrey G. Verwendung von Schwingquarzen zur Wagung dunner Schichten und zur Mikrowagung. Zeitschrift fur Physik 155 (1959) 206-222
    • (1959) Zeitschrift fur Physik , vol.155 , pp. 206-222
    • Sauerbrey, G.1
  • 3
    • 0347816738 scopus 로고
    • Frequency of a quartz microbalance in contact with liquid
    • Kanazawa K.K., and Gordon J.G. Frequency of a quartz microbalance in contact with liquid. Anal. Chem. 57 8 (1985) 1770-1771
    • (1985) Anal. Chem. , vol.57 , Issue.8 , pp. 1770-1771
    • Kanazawa, K.K.1    Gordon, J.G.2
  • 4
    • 36449008243 scopus 로고
    • Characterization of a thickness-shear mode quartz resonator with multiple nonpiezoelectric layers
    • Granstaff V.E., and Martin S.J. Characterization of a thickness-shear mode quartz resonator with multiple nonpiezoelectric layers. J. Appl. Phys. 75 3 (1994) 1319
    • (1994) J. Appl. Phys. , vol.75 , Issue.3 , pp. 1319
    • Granstaff, V.E.1    Martin, S.J.2
  • 5
    • 0030285682 scopus 로고    scopus 로고
    • Frequency and dissipation-factor responses to localized liquid deposits on a QCM electrode
    • Rodahl M., and Kasemo B. Frequency and dissipation-factor responses to localized liquid deposits on a QCM electrode. Sens. Actuators B (Chem.) B37 1-2 (1996) 111
    • (1996) Sens. Actuators B (Chem.) , vol.B37 , Issue.1-2 , pp. 111
    • Rodahl, M.1    Kasemo, B.2
  • 7
    • 71749089050 scopus 로고    scopus 로고
    • 9-10 MHz quartz resonators are commercially available from Maxtek Inc, A division of Inficon) and 27 MHz resonators are commercially available from Initium Inc.A division of Ulvac
    • 9-10 MHz quartz resonators are commercially available from Maxtek Inc. (A division of Inficon) and 27 MHz resonators are commercially available from Initium Inc.(A division of Ulvac).
  • 8
    • 0033151990 scopus 로고    scopus 로고
    • Modeling the responses of thickness-shear mode resonators under various loading conditions
    • Bandey H.L., et al. Modeling the responses of thickness-shear mode resonators under various loading conditions. Anal. Chem. 71 11 (1999) 2205-2214
    • (1999) Anal. Chem. , vol.71 , Issue.11 , pp. 2205-2214
    • Bandey, H.L.1
  • 9
    • 0000079247 scopus 로고    scopus 로고
    • On the measurement of thin liquid overlayers with the quartz-crystal microbalance.
    • Rodahl M., and Kasemo B. On the measurement of thin liquid overlayers with the quartz-crystal microbalance. Sens. Actuators A: Phys. 54 1-3 (1996) 448-456
    • (1996) Sens. Actuators A: Phys. , vol.54 , Issue.1-3 , pp. 448-456
    • Rodahl, M.1    Kasemo, B.2
  • 10
    • 0032691940 scopus 로고    scopus 로고
    • Viscoelastic acoustic response of layered polymer films at fluid-solid interfaces: continuum mechanics approach
    • Voinova M.V., Rodahl M., Jonson M., and Kasemo B. Viscoelastic acoustic response of layered polymer films at fluid-solid interfaces: continuum mechanics approach. Phys. Scr. 59 5 (1999) 391
    • (1999) Phys. Scr. , vol.59 , Issue.5 , pp. 391
    • Voinova, M.V.1    Rodahl, M.2    Jonson, M.3    Kasemo, B.4
  • 11
    • 0018483023 scopus 로고
    • The mechanism of the interaction of thin films with resonating quartz crystal substrates: the energy transfer model
    • Mecea V., and Bucur R.V. The mechanism of the interaction of thin films with resonating quartz crystal substrates: the energy transfer model. Thin Solid Films 60 1 (1979) 73-84
    • (1979) Thin Solid Films , vol.60 , Issue.1 , pp. 73-84
    • Mecea, V.1    Bucur, R.V.2
  • 12
    • 0029344809 scopus 로고
    • Fundamental limits on the frequency stabilities of crystal oscillators
    • Walls F.L., and Vig J.R. Fundamental limits on the frequency stabilities of crystal oscillators. Ultrason. Ferroelectr. Frequency Control IEEE Trans. 42 4 (1995) 576-589
    • (1995) Ultrason. Ferroelectr. Frequency Control IEEE Trans. , vol.42 , Issue.4 , pp. 576-589
    • Walls, F.L.1    Vig, J.R.2
  • 13
    • 14744287343 scopus 로고    scopus 로고
    • Resolution in quartz crystal oscillator circuits for high sensitivity microbalance sensors in damping media
    • Rodriguez-Pardo L., Farina J., Gabrielli C., Perrot H., and Brendel R. Resolution in quartz crystal oscillator circuits for high sensitivity microbalance sensors in damping media,. Sens. Actuators B [Chem.] 103 (2004) 318-324
    • (2004) Sens. Actuators B [Chem.] , vol.103 , pp. 318-324
    • Rodriguez-Pardo, L.1    Farina, J.2    Gabrielli, C.3    Perrot, H.4    Brendel, R.5
  • 14
    • 0034680544 scopus 로고    scopus 로고
    • Piezoelectric mass sensing devices as biosensors-an alternative to optical biosensors?
    • Janshoff A., Galla H.-J., and Steinem C. Piezoelectric mass sensing devices as biosensors-an alternative to optical biosensors?. Angew. Chem. Int. Ed. 39 (2000) 4004-4032
    • (2000) Angew. Chem. Int. Ed. , vol.39 , pp. 4004-4032
    • Janshoff, A.1    Galla, H.-J.2    Steinem, C.3
  • 15
    • 33646069306 scopus 로고    scopus 로고
    • High speed anisotropic etching of Pyrex(R) for microsystems applications
    • Goyal A., Hood V., and Tadigadapa S. High speed anisotropic etching of Pyrex(R) for microsystems applications. J. Non-Cryst. Solids 352 6-7 (2006) 657
    • (2006) J. Non-Cryst. Solids , vol.352 , Issue.6-7 , pp. 657
    • Goyal, A.1    Hood, V.2    Tadigadapa, S.3
  • 16
    • 49449083001 scopus 로고    scopus 로고
    • Human serum albumin adsorption study on 62-MHz miniaturized quartz gravimetric sensors.
    • Kao P., et al. Human serum albumin adsorption study on 62-MHz miniaturized quartz gravimetric sensors. Anal. Chem. (2008)
    • (2008) Anal. Chem.
    • Kao, P.1
  • 17
    • 71749107209 scopus 로고    scopus 로고
    • http://www.piercenet.com/files/0544as4.pdf.
  • 18
    • 0025493193 scopus 로고
    • A chemically modified electrode capable of a spontaneous immobilization of amino compounds due to its functionalization with succinimidyl groups
    • Katz E.Y. A chemically modified electrode capable of a spontaneous immobilization of amino compounds due to its functionalization with succinimidyl groups. J. Electroanal. Chem. 291 1-2 (1990) 257-260
    • (1990) J. Electroanal. Chem. , vol.291 , Issue.1-2 , pp. 257-260
    • Katz, E.Y.1
  • 19
    • 0033673212 scopus 로고    scopus 로고
    • Interfacial properties and the response of the transverse acoustic wave device in electrolytes
    • Ghafouri S., and Thompson M. Interfacial properties and the response of the transverse acoustic wave device in electrolytes. Electroanalysis 12 5 (2000) 326-336
    • (2000) Electroanalysis , vol.12 , Issue.5 , pp. 326-336
    • Ghafouri, S.1    Thompson, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.