Volumn 35, Issue 12, 2009, Pages 2007-2020

Quantification of Flow Using Ultrasound and Microbubbles: A Disruption Replenishment Model Based on Physical Principles

Author keywords

Blood flow; Contrast agents; Microbubble; Microcirculation

Indexed keywords

ACOUSTIC CONDITIONS; AXIAL PLANES; BLOOD FLOW; CLINICAL TOOLS; CONTRAST AGENT; CONTRAST ENHANCED ULTRASOUND; CROSS SECTION; EXPONENTIAL MODELS; FLOW PHANTOM; FLOW SYSTEMS; IMAGING PLANE; LOW MECHANICAL INDEX; MATHEMATICAL FUNCTIONS; MEASUREMENT DEVICE; MICRO-BUBBLE; MICROBUBBLES; MODEL-BASED; MOTION ARTIFACT; PHYSICAL PRINCIPLES; TIME COURSE; TIME-INTENSITY CURVES; ULTRASOUND BEAMS; ULTRASOUND FIELDS; VASCULAR SYSTEM;

EID: 71749084493     PISSN: 03015629     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ultrasmedbio.2009.06.1102     Document Type: Article
Times cited : (87)

References (27)
  • 1
    • 33746821518 scopus 로고    scopus 로고
    • A new formalism for the quantification of tissue perfusion by the destruction-replenishment method in contrast ultrasound imaging
    • Arditi M., Frinking P.J., Zhou X., and Rognin N.G. A new formalism for the quantification of tissue perfusion by the destruction-replenishment method in contrast ultrasound imaging. IEEE Trans Ultrason Ferroelectr Freq Control 53 (2006) 1118-1129
    • (2006) IEEE Trans Ultrason Ferroelectr Freq Control , vol.53 , pp. 1118-1129
    • Arditi, M.1    Frinking, P.J.2    Zhou, X.3    Rognin, N.G.4
  • 2
    • 0019942373 scopus 로고
    • Assessment of myocardial perfusion abnormalities with contrast-enhanced two-dimensional echocardiography
    • Armstrong W.F., Mueller T.M., Kinney E.L., Tickner E.G., Dillon J.C., and Feigenbaum H. Assessment of myocardial perfusion abnormalities with contrast-enhanced two-dimensional echocardiography. Circulation 66 (1982) 166-173
    • (1982) Circulation , vol.66 , pp. 166-173
    • Armstrong, W.F.1    Mueller, T.M.2    Kinney, E.L.3    Tickner, E.G.4    Dillon, J.C.5    Feigenbaum, H.6
  • 3
    • 1942485934 scopus 로고    scopus 로고
    • An optimal lognormal approximation to lognormal sum distributions
    • Beaulieu N.C., and Xie Q. An optimal lognormal approximation to lognormal sum distributions. IEEE Trans Vehicular Tech 53 (2004) 479-489
    • (2004) IEEE Trans Vehicular Tech , vol.53 , pp. 479-489
    • Beaulieu, N.C.1    Xie, Q.2
  • 7
    • 0021367345 scopus 로고
    • In vivo correlation of thermodilution cardiac output and videodensitometric indicator-dilution curves obtained from contrast two-dimensional echocardiograms
    • DeMaria A.N., Bommer W., Kwan O.L., Riggs K., Smith M., and Waters J. In vivo correlation of thermodilution cardiac output and videodensitometric indicator-dilution curves obtained from contrast two-dimensional echocardiograms. J Am Coll Cardiol 3 (1984) 999-1004
    • (1984) J Am Coll Cardiol , vol.3 , pp. 999-1004
    • DeMaria, A.N.1    Bommer, W.2    Kwan, O.L.3    Riggs, K.4    Smith, M.5    Waters, J.6
  • 8
    • 3242697895 scopus 로고    scopus 로고
    • The powerful microbubble: From bench to bedside, from intravascular indicator to therapeutic delivery system, and beyond
    • Feinstein S.B. The powerful microbubble: From bench to bedside, from intravascular indicator to therapeutic delivery system, and beyond. Am J Physiol Heart Circ Physiol 287 (2004) H450-H457
    • (2004) Am J Physiol Heart Circ Physiol , vol.287
    • Feinstein, S.B.1
  • 9
    • 33745685392 scopus 로고    scopus 로고
    • Contrast ultrasound imaging of the carotid artery vasa vasorum and atherosclerotic plaque neovascularization
    • Feinstein S.B. Contrast ultrasound imaging of the carotid artery vasa vasorum and atherosclerotic plaque neovascularization. J Am Coll Cardiol 48 (2006) 236-243
    • (2006) J Am Coll Cardiol , vol.48 , pp. 236-243
    • Feinstein, S.B.1
  • 10
    • 34548120566 scopus 로고    scopus 로고
    • Attenuation and size distribution measurements of Definity and manipulated Definity populations
    • Goertz D.E., de Jong N., and van der Steen A.F. Attenuation and size distribution measurements of Definity and manipulated Definity populations. Ultrasound Med Biol 33 (2007) 1376-1388
    • (2007) Ultrasound Med Biol , vol.33 , pp. 1376-1388
    • Goertz, D.E.1    de Jong, N.2    van der Steen, A.F.3
  • 11
    • 0035080015 scopus 로고    scopus 로고
    • Prostate cancer: Contrast-enhanced us for detection
    • Halpern E.J., Rosenberg M., and Gomella L.G. Prostate cancer: Contrast-enhanced us for detection. Radiology 219 (2001) 219-225
    • (2001) Radiology , vol.219 , pp. 219-225
    • Halpern, E.J.1    Rosenberg, M.2    Gomella, L.G.3
  • 12
    • 0025392747 scopus 로고
    • Method for the quantitation of myocardial perfusion during myocardial contrast two-dimensional echocardiography
    • Jayaweera A.R., Matthew T.L., Sklenar J., Spotnitz W.D., Watson D.D., and Kaul S. Method for the quantitation of myocardial perfusion during myocardial contrast two-dimensional echocardiography. J Am Soc Echocardiogr 3 (1990) 91-98
    • (1990) J Am Soc Echocardiogr , vol.3 , pp. 91-98
    • Jayaweera, A.R.1    Matthew, T.L.2    Sklenar, J.3    Spotnitz, W.D.4    Watson, D.D.5    Kaul, S.6
  • 13
    • 0141928675 scopus 로고    scopus 로고
    • Transit time kinetics in ordered and disordered vascular trees
    • Karshafian R., Burns P.N., and Henkelman M.R. Transit time kinetics in ordered and disordered vascular trees. Phys Med Biol 48 (2003) 3225-3237
    • (2003) Phys Med Biol , vol.48 , pp. 3225-3237
    • Karshafian, R.1    Burns, P.N.2    Henkelman, M.R.3
  • 14
    • 0030730241 scopus 로고    scopus 로고
    • Myocardial contrast echocardiography: 15 years of research and development
    • Kaul S. Myocardial contrast echocardiography: 15 years of research and development. Circulation 96 (1997) 3745-3760
    • (1997) Circulation , vol.96 , pp. 3745-3760
    • Kaul, S.1
  • 15
    • 0035118925 scopus 로고    scopus 로고
    • Blood flow assessment by ultrasound-induced destruction of echocontrast agents using harmonic power Doppler imaging: Which parameters determine contrast replenishment curves?
    • Koster J., Schlosser T., Pohl C., Lentz C., Lohmaier S., Veltmann C., Kuntz-Hehner S., Omran H., Luderitz B., Becher H., and Tiemann K. Blood flow assessment by ultrasound-induced destruction of echocontrast agents using harmonic power Doppler imaging: Which parameters determine contrast replenishment curves?. Echocardiography 18 (2001) 1-8
    • (2001) Echocardiography , vol.18 , pp. 1-8
    • Koster, J.1    Schlosser, T.2    Pohl, C.3    Lentz, C.4    Lohmaier, S.5    Veltmann, C.6    Kuntz-Hehner, S.7    Omran, H.8    Luderitz, B.9    Becher, H.10    Tiemann, K.11
  • 16
    • 0242302292 scopus 로고    scopus 로고
    • A multivessel model describing replenishment kinetics of ultrasound contrast agent for quantification of tissue perfusion
    • Krix M., Kiessling F., Farhan N., Schmidt K., Hoffend J., and Delorme S. A multivessel model describing replenishment kinetics of ultrasound contrast agent for quantification of tissue perfusion. Ultrasound Med Biol 29 (2003) 1421-1430
    • (2003) Ultrasound Med Biol , vol.29 , pp. 1421-1430
    • Krix, M.1    Kiessling, F.2    Farhan, N.3    Schmidt, K.4    Hoffend, J.5    Delorme, S.6
  • 17
    • 0042844541 scopus 로고    scopus 로고
    • Blood flow quantification with contrast-enhanced US: "Entrance in the section" phenomenon-phantom and rabbit study
    • Lucidarme O., Franchi-Abella S., Correas J.M., Bridal S.L., Kurtisovski E., and Berger G. Blood flow quantification with contrast-enhanced US: "Entrance in the section" phenomenon-phantom and rabbit study. Radiology 228 (2003) 473-479
    • (2003) Radiology , vol.228 , pp. 473-479
    • Lucidarme, O.1    Franchi-Abella, S.2    Correas, J.M.3    Bridal, S.L.4    Kurtisovski, E.5    Berger, G.6
  • 18
    • 0037851014 scopus 로고    scopus 로고
    • Videodensitometric methods for cardiac output measurements
    • Mischi M., Kalker T., and Korsten E. Videodensitometric methods for cardiac output measurements. EURASIP J Appl Signal Proc 5 (2003) 479-489
    • (2003) EURASIP J Appl Signal Proc , vol.5 , pp. 479-489
    • Mischi, M.1    Kalker, T.2    Korsten, E.3
  • 20
    • 1642305421 scopus 로고    scopus 로고
    • Analysis of refill curve shape in ultrasound contrast agent studies
    • Potdevin T.C., Fowlkes J.B., Moskalik A.P., and Carson P.L. Analysis of refill curve shape in ultrasound contrast agent studies. Med Phys 31 (2004) 623-632
    • (2004) Med Phys , vol.31 , pp. 623-632
    • Potdevin, T.C.1    Fowlkes, J.B.2    Moskalik, A.P.3    Carson, P.L.4
  • 21
    • 0034698013 scopus 로고    scopus 로고
    • A class of flow bifurcation models with lognormal distribution and fractal dispersion
    • Qian H., and Bassingthwaighte J.B. A class of flow bifurcation models with lognormal distribution and fractal dispersion. J Theor Biol 205 (2000) 261-268
    • (2000) J Theor Biol , vol.205 , pp. 261-268
    • Qian, H.1    Bassingthwaighte, J.B.2
  • 22
    • 0028129040 scopus 로고
    • Quantification of myocardial perfusion with myocardial contrast echocardiography during left atrial injection of contrast. Implications for venous injection
    • Skyba D.M., Jayaweera A.R., Goodman N.C., Ismail S., Camarano G., and Kaul S. Quantification of myocardial perfusion with myocardial contrast echocardiography during left atrial injection of contrast. Implications for venous injection. Circulation 90 (1994) 1513-1521
    • (1994) Circulation , vol.90 , pp. 1513-1521
    • Skyba, D.M.1    Jayaweera, A.R.2    Goodman, N.C.3    Ismail, S.4    Camarano, G.5    Kaul, S.6
  • 23
    • 0036082485 scopus 로고    scopus 로고
    • On the design of a capillary flow phantom for the evaluation of ultrasound contrast agents at very low flow velocities
    • Veltmann C., Lohmaier S., Schlosser T., Shai S., Ehlgen A., Pohl C., Becher H., and Tiemann K. On the design of a capillary flow phantom for the evaluation of ultrasound contrast agents at very low flow velocities. Ultrasound Med Biol 28 (2002) 625-634
    • (2002) Ultrasound Med Biol , vol.28 , pp. 625-634
    • Veltmann, C.1    Lohmaier, S.2    Schlosser, T.3    Shai, S.4    Ehlgen, A.5    Pohl, C.6    Becher, H.7    Tiemann, K.8
  • 24
    • 0036634602 scopus 로고    scopus 로고
    • Assessment of myocardial blood flow and volume using myocardial contrast echocardiography
    • Wei K. Assessment of myocardial blood flow and volume using myocardial contrast echocardiography. Echocardiography 19 (2002) 409-416
    • (2002) Echocardiography , vol.19 , pp. 409-416
    • Wei, K.1
  • 25
    • 0032501992 scopus 로고    scopus 로고
    • Quantification of myocardial blood flow with ultrasound-induced destruction of microbubbles administered as a constant venous infusion
    • Wei K., Jayaweera A.R., Firoozan S., Linka A., Skyba D.M., and Kaul S. Quantification of myocardial blood flow with ultrasound-induced destruction of microbubbles administered as a constant venous infusion. Circulation 97 (1998) 473-483
    • (1998) Circulation , vol.97 , pp. 473-483
    • Wei, K.1    Jayaweera, A.R.2    Firoozan, S.3    Linka, A.4    Skyba, D.M.5    Kaul, S.6
  • 26
    • 0034067847 scopus 로고    scopus 로고
    • Harmonic hepatic US with microbubble contrast agent: Initial experience showing improved characterization of hemangioma, hepatocellular carcinoma, and metastasis
    • Wilson S.R., Burns P.N., Muradali D., Wilson J.A., and Lai X. Harmonic hepatic US with microbubble contrast agent: Initial experience showing improved characterization of hemangioma, hepatocellular carcinoma, and metastasis. Radiology 215 (2000) 153-161
    • (2000) Radiology , vol.215 , pp. 153-161
    • Wilson, S.R.1    Burns, P.N.2    Muradali, D.3    Wilson, J.A.4    Lai, X.5
  • 27
    • 34249894709 scopus 로고    scopus 로고
    • Diagnosis of focal liver masses on ultrasonography: Comparison of unenhanced and contrast-enhanced scans
    • quiz 88-90
    • Wilson S.R., Jang H.J., Kim T.K., and Burns P.N. Diagnosis of focal liver masses on ultrasonography: Comparison of unenhanced and contrast-enhanced scans. J Ultrasound Med 26 (2007) 775-787 quiz 88-90
    • (2007) J Ultrasound Med , vol.26 , pp. 775-787
    • Wilson, S.R.1    Jang, H.J.2    Kim, T.K.3    Burns, P.N.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.