메뉴 건너뛰기




Volumn 7259, Issue , 2009, Pages

Worst-case analysis of target localization errors in fiducial-based rigid body registration

Author keywords

Image guided therapy; Rigid registration

Indexed keywords

ESTIMATION FORMULAE; ESTIMATION METHODS; FIDUCIALS; FITZPATRICK; IMAGE GUIDED THERAPY; IMAGE-GUIDED SURGERY SYSTEMS; INTRA-OPERATIVE; LOCALIZATION ERRORS; PREOPERATIVE IMAGES; REGISTRATION ERROR; RIGID BODY; RIGID REGISTRATION; TARGET LOCALIZATION; TARGET LOCATION; TARGET REGISTRATION ERRORS; WORST CASE; WORST-CASE ANALYSIS;

EID: 71649113996     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.811038     Document Type: Conference Paper
Times cited : (8)

References (21)
  • 4
    • 0037295469 scopus 로고    scopus 로고
    • Magnetic resonance imaging in the radiation treatment planning of localized prostate cancer using intra-prostatic fiducial markers for computed tomography co-registration
    • Parker, C.C., Damyanovich, A., Haycocks, T., Haider, M., Bayley, A., and Catton, C.N., "Magnetic resonance imaging in the radiation treatment planning of localized prostate cancer using intra-prostatic fiducial markers for computed tomography co-registration," Radiotherapy Oncology, 66, 217-24 (2003).
    • (2003) Radiotherapy Oncology , vol.66 , pp. 217-224
    • Parker, C.C.1    Damyanovich, A.2    Haycocks, T.3    Haider, M.4    Bayley, A.5    Catton, C.N.6
  • 5
    • 0038479991 scopus 로고    scopus 로고
    • Accuracy of prostate radiation therapy using a fiducial point-pair registration technique based on the computer-assisted portal imaging quality assurance program PIPSpro
    • Mermershtain, W., Cohen, Y., and Krutman, Y., "Accuracy of prostate radiation therapy using a fiducial point-pair registration technique based on the computer-assisted portal imaging quality assurance program PIPSpro," Australas Radiology, 47, 168-71 (2003).
    • (2003) Australas Radiology , vol.47 , pp. 168-171
    • Mermershtain, W.1    Cohen, Y.2    Krutman, Y.3
  • 6
    • 85057403488 scopus 로고    scopus 로고
    • Hajnal, J.V., Hill, D.L.G., Hawkes, D.J., [Medical Image Registration], CRC Press, Florida, 11-38 (2001).
    • Hajnal, J.V., Hill, D.L.G., Hawkes, D.J., [Medical Image Registration], CRC Press, Florida, 11-38 (2001).
  • 9
    • 0029793771 scopus 로고    scopus 로고
    • Use of a biocompatible fiducial marker in evaluating the accuracy of computed tomography image registration
    • Ellis, R., Toksvig-Larsen, S., Marcacci, M., Caramella, D., and Fadda, M., "Use of a biocompatible fiducial marker in evaluating the accuracy of computed tomography image registration," Interventional Radiology, 31, 658-67 (1996).
    • (1996) Interventional Radiology , vol.31 , pp. 658-667
    • Ellis, R.1    Toksvig-Larsen, S.2    Marcacci, M.3    Caramella, D.4    Fadda, M.5
  • 12
    • 0033688840 scopus 로고    scopus 로고
    • Point-based, rigid registration: Clinical validation of theory
    • West, J.B., and Fitzpatrick, J.M., "Point-based, rigid registration: clinical validation of theory," Proc. SPIE Medical Imaging (2000).
    • (2000) Proc. SPIE Medical Imaging
    • West, J.B.1    Fitzpatrick, J.M.2
  • 16
    • 40149095934 scopus 로고    scopus 로고
    • A statistical model for point-based target registration error with anisotropic fiducial localizer error
    • Wiles, A.D., Likholyot, A., Frantz, D.D., and Peters, T.M., "A statistical model for point-based target registration error with anisotropic fiducial localizer error," IEEE Transactions on Medical Imaging, 27, 378-90 (2008).
    • (2008) IEEE Transactions on Medical Imaging , vol.27 , pp. 378-390
    • Wiles, A.D.1    Likholyot, A.2    Frantz, D.D.3    Peters, T.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.