메뉴 건너뛰기




Volumn 44, Issue 1, 2010, Pages 41-57

Low-pressure membrane integrity tests for drinking water treatment: A review

Author keywords

Drinking water; Low pressure membrane; Membrane integrity; Microfiltration; Ultrafiltration

Indexed keywords

FIBER OPTIC SENSORS; MEMBRANES; MICROFILTRATION; MONITORING; TESTING; ULTRAFILTRATION; WATER FILTRATION; WATER TREATMENT;

EID: 71549168598     PISSN: 00431354     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.watres.2009.09.032     Document Type: Review
Times cited : (163)

References (61)
  • 3
    • 71549126012 scopus 로고    scopus 로고
    • Sub-micron Particles in Drinking Water and their Role in Monitoring the Performance of Filtration Processes
    • Tampa FL
    • Banerjee, A., Lambertson, M., Carlson, K., 1999. Sub-micron Particles in Drinking Water and their Role in Monitoring the Performance of Filtration Processes. The AWWA Water Quality Technology Conference, Tampa FL.
    • (1999) The AWWA Water Quality Technology Conference
    • Banerjee, A.1    Lambertson, M.2    Carlson, K.3
  • 5
    • 31344448288 scopus 로고    scopus 로고
    • Maintaining the integrity of filtration systems
    • Bennett A. Maintaining the integrity of filtration systems. Filtration & Separation 42 1 (2005) 30-33
    • (2005) Filtration & Separation , vol.42 , Issue.1 , pp. 30-33
    • Bennett, A.1
  • 6
    • 57049102956 scopus 로고    scopus 로고
    • Drinking water: pathogen removal from water - technologies and techniques
    • Bennett A. Drinking water: pathogen removal from water - technologies and techniques. Filtration & Separation 45 10 (2008) 14-16
    • (2008) Filtration & Separation , vol.45 , Issue.10 , pp. 14-16
    • Bennett, A.1
  • 7
    • 52249093071 scopus 로고    scopus 로고
    • Risk Management Approach for Monitoring UF Membrane Integrity and Experimental Validation using MS2-phages
    • Austria Vienna
    • Brehant, A., Glucina, K., Lemoigne, I., Laine, J.M., 2008. Risk Management Approach for Monitoring UF Membrane Integrity and Experimental Validation using MS2-phages. IWA World Water Congress, Austria Vienna.
    • (2008) IWA World Water Congress
    • Brehant, A.1    Glucina, K.2    Lemoigne, I.3    Laine, J.M.4
  • 8
    • 0037056879 scopus 로고    scopus 로고
    • Study of the effects of defect in ultrafiltration membranes on the water flux and the molecular weight cut-off
    • Causserand C., Aimar P., Vilani C., and Zambeli T. Study of the effects of defect in ultrafiltration membranes on the water flux and the molecular weight cut-off. Desalination 149 1-3 (2002) 485-491
    • (2002) Desalination , vol.149 , Issue.1-3 , pp. 485-491
    • Causserand, C.1    Aimar, P.2    Vilani, C.3    Zambeli, T.4
  • 11
    • 0037057017 scopus 로고    scopus 로고
    • Improving membrane integrity monitoring indirect methods to reduce plant downtime and increase microbial removal credit
    • Crozes G.F., Sethi S., Xi B., Curl J., and Mariñas B. Improving membrane integrity monitoring indirect methods to reduce plant downtime and increase microbial removal credit. Desalination 149 1-3 (2002) 493-497
    • (2002) Desalination , vol.149 , Issue.1-3 , pp. 493-497
    • Crozes, G.F.1    Sethi, S.2    Xi, B.3    Curl, J.4    Mariñas, B.5
  • 13
    • 43549126183 scopus 로고    scopus 로고
    • Use of paramagnetic particles in membrane integrity testing
    • Deluhery J., and Rajagopalan N. Use of paramagnetic particles in membrane integrity testing. Journal of Membrane Science 318 1-2 (2008) 176-181
    • (2008) Journal of Membrane Science , vol.318 , Issue.1-2 , pp. 176-181
    • Deluhery, J.1    Rajagopalan, N.2
  • 14
    • 0011287999 scopus 로고
    • Integrity test for membranes
    • U.S. Patent 5,282,380
    • DiLeo, A.J., Phillips, M.W., 1994. Integrity test for membranes. U.S. Patent 5,282,380.
    • (1994)
    • DiLeo, A.J.1    Phillips, M.W.2
  • 15
    • 0342600873 scopus 로고
    • Process for evaluating solute retention characteristics of membranes
    • U.S. Patent 5,457,986
    • DiLeo, A.J., Phillips, M.W., 1995. Process for evaluating solute retention characteristics of membranes. U.S. Patent 5,457,986.
    • (1995)
    • DiLeo, A.J.1    Phillips, M.W.2
  • 16
    • 0035334964 scopus 로고    scopus 로고
    • Membrane solution to a "significant risk" Cryptosporidium groundwater source
    • Edwards D., Donn A., and Meadowcroft C. Membrane solution to a "significant risk" Cryptosporidium groundwater source. Dasalination 137 1-3 (2001) 193-198
    • (2001) Dasalination , vol.137 , Issue.1-3 , pp. 193-198
    • Edwards, D.1    Donn, A.2    Meadowcroft, C.3
  • 18
    • 2442464761 scopus 로고    scopus 로고
    • Estimating air diffusion contribution to pressure decay during membrane integrity tests
    • Farahbakhsh K., and Smith D.W. Estimating air diffusion contribution to pressure decay during membrane integrity tests. Journal of Membrane Science 237 1-2 (2004) 203-212
    • (2004) Journal of Membrane Science , vol.237 , Issue.1-2 , pp. 203-212
    • Farahbakhsh, K.1    Smith, D.W.2
  • 19
    • 0038541943 scopus 로고    scopus 로고
    • Monitoring the integrity of low-pressure water treatment membranes
    • Farahbakhsh K., Adham S.S., and Smith D.W. Monitoring the integrity of low-pressure water treatment membranes. Journal AWWA 95 6 (2004) 95-107
    • (2004) Journal AWWA , vol.95 , Issue.6 , pp. 95-107
    • Farahbakhsh, K.1    Adham, S.S.2    Smith, D.W.3
  • 21
    • 85189268705 scopus 로고    scopus 로고
    • FILMTEC Membranes
    • FILMTEC Membranes, Troubleshooting: Membrane Element Evaluation (http://www.dow.com/PublishedLiterature/dh_003d/0901b8038003d390.pdf?filepath=liquidseps/pdfs/noreg/609-02115.pdf&fromPage=GetDoc).
    • Troubleshooting: Membrane Element Evaluation
  • 23
    • 0342547076 scopus 로고    scopus 로고
    • A liquid porosimetry technique for correlating intrinsic protein sieving: application in ultrafiltration processes
    • Gadam S., Philippe M., Orlando S., Kuriyel R., Pearl S., and Zydney A. A liquid porosimetry technique for correlating intrinsic protein sieving: application in ultrafiltration processes. Journal of Membrane Science 133 1 (1997) 111-125
    • (1997) Journal of Membrane Science , vol.133 , Issue.1 , pp. 111-125
    • Gadam, S.1    Philippe, M.2    Orlando, S.3    Kuriyel, R.4    Pearl, S.5    Zydney, A.6
  • 24
    • 0024575057 scopus 로고
    • Membrane characterization using porosimetry and contact angle measurements: a comparison with experimental UF results
    • Gekas V., and Zhang W. Membrane characterization using porosimetry and contact angle measurements: a comparison with experimental UF results. Process Biochemistry 24 5 (1989) 159-166
    • (1989) Process Biochemistry , vol.24 , Issue.5 , pp. 159-166
    • Gekas, V.1    Zhang, W.2
  • 25
    • 48149105644 scopus 로고    scopus 로고
    • High sensitivity binary gas integrity test for membrane filters
    • Giglia S., and Krishnan M. High sensitivity binary gas integrity test for membrane filters. Journal of Membrane Science 323 1 (2008) 60-66
    • (2008) Journal of Membrane Science , vol.323 , Issue.1 , pp. 60-66
    • Giglia, S.1    Krishnan, M.2
  • 26
    • 33646816776 scopus 로고    scopus 로고
    • Fiber failure frequency and causes of hollow fiber integrity loss
    • Gijsbertsen A.J., Cornelissen E.R., and Hofman J.A.M.H. Fiber failure frequency and causes of hollow fiber integrity loss. Desalination 194 1-3 (2006) 251-258
    • (2006) Desalination , vol.194 , Issue.1-3 , pp. 251-258
    • Gijsbertsen, A.J.1    Cornelissen, E.R.2    Hofman, J.A.M.H.3
  • 27
    • 0036803172 scopus 로고    scopus 로고
    • Fluorescent dye labeled bacteriophages - a new tracer for the investigation of viral transport in porous media: 1. Introduction and characterization
    • Gitis V., Adin A., Nasser A., Gun J., and Lev O. Fluorescent dye labeled bacteriophages - a new tracer for the investigation of viral transport in porous media: 1. Introduction and characterization. Water Research 36 17 (2002) 4227-4234
    • (2002) Water Research , vol.36 , Issue.17 , pp. 4227-4234
    • Gitis, V.1    Adin, A.2    Nasser, A.3    Gun, J.4    Lev, O.5
  • 28
    • 33645391297 scopus 로고    scopus 로고
    • Application of nanoscale probes for the evaluation of the integrity of ultrafiltration membranes
    • Gitis V., Haught R.C., Clark R.M., Gun J., and Lev O. Application of nanoscale probes for the evaluation of the integrity of ultrafiltration membranes. Journal of Membrane Science 276 1-2 (2006) 185-192
    • (2006) Journal of Membrane Science , vol.276 , Issue.1-2 , pp. 185-192
    • Gitis, V.1    Haught, R.C.2    Clark, R.M.3    Gun, J.4    Lev, O.5
  • 29
    • 33645396452 scopus 로고    scopus 로고
    • Nanoscale probes for the evaluation of the integrity of ultrafiltration membranes
    • Gitis V., Haught R.C., Clark R.M., Gun J., and Lev O. Nanoscale probes for the evaluation of the integrity of ultrafiltration membranes. Journal of Membrane Science 276 1-2 (2006) 199-207
    • (2006) Journal of Membrane Science , vol.276 , Issue.1-2 , pp. 199-207
    • Gitis, V.1    Haught, R.C.2    Clark, R.M.3    Gun, J.4    Lev, O.5
  • 31
    • 0032442261 scopus 로고    scopus 로고
    • Experimental assessment of the efficacy of microfiltration and ultrafiltration for Cryptosporidium removal
    • Hirata T., and Hashimoto A. Experimental assessment of the efficacy of microfiltration and ultrafiltration for Cryptosporidium removal. Water Science and Technology 38 12 (1998) 103-107
    • (1998) Water Science and Technology , vol.38 , Issue.12 , pp. 103-107
    • Hirata, T.1    Hashimoto, A.2
  • 32
    • 0028972334 scopus 로고
    • Sub-critical flux operation of microfiltration
    • Howell J.A. Sub-critical flux operation of microfiltration. Journal of Membrane Science 107 1-2 (1995) 165-171
    • (1995) Journal of Membrane Science , vol.107 , Issue.1-2 , pp. 165-171
    • Howell, J.A.1
  • 33
    • 0012521860 scopus 로고    scopus 로고
    • Membrane Filtration for Microbial Removal
    • Report No. 90715, American Water Works Association Research Foundation, Denver, CO
    • Jacangelo, J., Adham, S., Laine, J.-M., 1997. Membrane Filtration for Microbial Removal, Report No. 90715, American Water Works Association Research Foundation, Denver, CO.
    • (1997)
    • Jacangelo, J.1    Adham, S.2    Laine, J.-M.3
  • 36
    • 0031277862 scopus 로고    scopus 로고
    • Automatic monitoring of membrane integrity in microfiltration systems
    • Johnson W.T. Automatic monitoring of membrane integrity in microfiltration systems. Desalination 113 2-3 (1997) 303-307
    • (1997) Desalination , vol.113 , Issue.2-3 , pp. 303-307
    • Johnson, W.T.1
  • 37
    • 0031652066 scopus 로고    scopus 로고
    • Predicting log removal performance of membrane systems using in-situ integrity testing
    • Johnson W.T. Predicting log removal performance of membrane systems using in-situ integrity testing. Filtration & Separation 1 35 (1998) 26-29
    • (1998) Filtration & Separation , vol.1 , Issue.35 , pp. 26-29
    • Johnson, W.T.1
  • 39
    • 0032552612 scopus 로고    scopus 로고
    • Acoustic sensor: a novel technique for low pressure membrane integrity monitoring
    • Laîne J.M., Glucina K., Chamant M., and Simonie P. Acoustic sensor: a novel technique for low pressure membrane integrity monitoring. Desalination 119 1-3 (1998) 73-77
    • (1998) Desalination , vol.119 , Issue.1-3 , pp. 73-77
    • Laîne, J.M.1    Glucina, K.2    Chamant, M.3    Simonie, P.4
  • 42
    • 58149180040 scopus 로고    scopus 로고
    • Effects of nanoparticles on the ultrafiltration of surface water
    • Lohwacharin J., and Takizawa S. Effects of nanoparticles on the ultrafiltration of surface water. Journal of Membrane Science 326 2 (2009) 354-362
    • (2009) Journal of Membrane Science , vol.326 , Issue.2 , pp. 354-362
    • Lohwacharin, J.1    Takizawa, S.2
  • 45
    • 27644491215 scopus 로고    scopus 로고
    • Membrane integrity - direct turbidity measurement of filtrate from MF membrane module at an operating potable water treatment plant
    • Naismith J. Membrane integrity - direct turbidity measurement of filtrate from MF membrane module at an operating potable water treatment plant. Desalination 179 1-3 (2005) 25-30
    • (2005) Desalination , vol.179 , Issue.1-3 , pp. 25-30
    • Naismith, J.1
  • 46
    • 0345040617 scopus 로고    scopus 로고
    • Monitoring the integrity of capillary membranes by particle counters
    • Panglisch S., Deinert U., Dautzenberg W., Kiepke O., and Gimbel R. Monitoring the integrity of capillary membranes by particle counters. Desalination 119 1-3 (1998) 65-72
    • (1998) Desalination , vol.119 , Issue.1-3 , pp. 65-72
    • Panglisch, S.1    Deinert, U.2    Dautzenberg, W.3    Kiepke, O.4    Gimbel, R.5
  • 47
    • 34247613538 scopus 로고    scopus 로고
    • Water and wastewater filtration: membrane module format
    • Pearce G. Water and wastewater filtration: membrane module format. Filtration & Separation 44 4 (2007) 31-33
    • (2007) Filtration & Separation , vol.44 , Issue.4 , pp. 31-33
    • Pearce, G.1
  • 48
    • 85189261275 scopus 로고    scopus 로고
    • Phattaranawik, J., Fane, A.G., Wong, F.S., 2007. Detection apparatus and method utilizing membranes and ratio of transmembrane pressures. PCT/SG2007/000130, WO/2007/129994.
    • Phattaranawik, J., Fane, A.G., Wong, F.S., 2007. Detection apparatus and method utilizing membranes and ratio of transmembrane pressures. PCT/SG2007/000130, WO/2007/129994.
  • 49
    • 48349105080 scopus 로고    scopus 로고
    • Novel membrane-based sensor for online membrane integrity monitoring
    • Phattaranawik J., Fane A.G., and Wong F.S. Novel membrane-based sensor for online membrane integrity monitoring. Journal of Membrane Science 323 1 (2008) 113-124
    • (2008) Journal of Membrane Science , vol.323 , Issue.1 , pp. 113-124
    • Phattaranawik, J.1    Fane, A.G.2    Wong, F.S.3
  • 50
    • 0030239364 scopus 로고    scopus 로고
    • A validatable porosimetric technique for verifying the integrity of virus retentive membranes
    • Phillips M.W., and DiLeo A.J. A validatable porosimetric technique for verifying the integrity of virus retentive membranes. Biologicals 24 3 (1996) 243-253
    • (1996) Biologicals , vol.24 , Issue.3 , pp. 243-253
    • Phillips, M.W.1    DiLeo, A.J.2
  • 52
    • 85189255357 scopus 로고    scopus 로고
    • Methods and systems for membrane testing
    • 011
    • Rajagopalan N., Rusk T., and Sanford R. Methods and systems for membrane testing. US Patent 7 (2006) 758 011
    • (2006) US Patent , vol.7 , pp. 758
    • Rajagopalan, N.1    Rusk, T.2    Sanford, R.3
  • 53
    • 0030964796 scopus 로고    scopus 로고
    • Large scale operating experience in membrane systems for water and waste water reclamation
    • Randles N. Large scale operating experience in membrane systems for water and waste water reclamation. Desalination 108 1-3 (1997) 205-211
    • (1997) Desalination , vol.108 , Issue.1-3 , pp. 205-211
    • Randles, N.1
  • 55
    • 0034750979 scopus 로고    scopus 로고
    • Demonstrating the integrity of a large scale microfiltration plant using a bacillus spore challenge test
    • Trimboli P., Lozier J., and Johnson W. Demonstrating the integrity of a large scale microfiltration plant using a bacillus spore challenge test. Water Science & Technology: Water Supply 1 5-6 (2001) 1-12
    • (2001) Water Science & Technology: Water Supply , vol.1 , Issue.5-6 , pp. 1-12
    • Trimboli, P.1    Lozier, J.2    Johnson, W.3
  • 56
    • 85189279784 scopus 로고    scopus 로고
    • U.S. EPA, 2001. Low-Pressure Membrane Filtration for Pathogen Removal: Application Implementation, and Regulatory Issues. EPA 815-c-01-001, U.S. Environmental Protection Agency Office of Water.
    • U.S. EPA, 2001. Low-Pressure Membrane Filtration for Pathogen Removal: Application Implementation, and Regulatory Issues. EPA 815-c-01-001, U.S. Environmental Protection Agency Office of Water.
  • 57
    • 85189255580 scopus 로고    scopus 로고
    • U.S. EPA, 2003. Membrane Filtration Guidance Manual. EPA 915-d-03-008, U.S. Environmental Protection Agency Office of Water.
    • U.S. EPA, 2003. Membrane Filtration Guidance Manual. EPA 915-d-03-008, U.S. Environmental Protection Agency Office of Water.
  • 60
    • 0000557687 scopus 로고
    • Separation of gases by fractional permeation through membranes
    • Weller S., and Steiner W. Separation of gases by fractional permeation through membranes. Journal of Applied Physics 21 (1950) 279-283
    • (1950) Journal of Applied Physics , vol.21 , pp. 279-283
    • Weller, S.1    Steiner, W.2
  • 61
    • 34547911058 scopus 로고    scopus 로고
    • Statistical analysis of data from accelerated aging tests of PES UF membranes
    • Zondervan E., Zwijinenburg A., and Roffel B. Statistical analysis of data from accelerated aging tests of PES UF membranes. Journal of Membrane Science 300 1-2 (2007) 111-116
    • (2007) Journal of Membrane Science , vol.300 , Issue.1-2 , pp. 111-116
    • Zondervan, E.1    Zwijinenburg, A.2    Roffel, B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.