Volumn 323, Issue 1, 2008, Pages 113-124

Novel membrane-based sensor for online membrane integrity monitoring

Author keywords

Membrane failure; Membrane integrity monitoring; Particle monitoring; Porous membrane; Relative trans membrane pressure

Indexed keywords

BENTONITE; CONCENTRATION (PROCESS); DETECTORS; FIBER OPTIC SENSORS; FILTRATION; FOULING; GROUND OPERATIONS; MEMBRANES; MILITARY OPERATIONS; POROUS MATERIALS; POSITIVE IONS; RELIABILITY; SCALE (DEPOSITS); SENSORS; SYSTEM STABILITY; TURBIDITY; VACUUM;

EID: 48349105080     PISSN: 03767388     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.memsci.2008.06.008     Document Type: Article
Times cited : (25)

References (14)
  • 1
    • 0037057017 scopus 로고    scopus 로고
    • Improving membrane integrity monitoring indirect methods to reduce plant downtime and increase microbial removal credit
    • Crozes G.F., Sethi S., Mi B., Curl J., and Marinas B. Improving membrane integrity monitoring indirect methods to reduce plant downtime and increase microbial removal credit. Desalination 149 (2002) 493-497
    • (2002) Desalination , vol.149 , pp. 493-497
    • Crozes, G.F.1    Sethi, S.2    Mi, B.3    Curl, J.4    Marinas, B.5
  • 2
    • 0032552612 scopus 로고    scopus 로고
    • Acoustic sensor: a novel technique for low pressure membrane integrity monitoring
    • Laine J.M., Glucina K., Chamant M., and Simonie P. Acoustic sensor: a novel technique for low pressure membrane integrity monitoring. Desalination 119 (1998) 73-77
    • (1998) Desalination , vol.119 , pp. 73-77
    • Laine, J.M.1    Glucina, K.2    Chamant, M.3    Simonie, P.4
  • 3
    • 0003953841 scopus 로고    scopus 로고
    • Lyonnaise des Eaux, and water research commission of South Africa
    • American Water Works Association Research Foundation, McGraw-Hill, New York
    • American Water Works Association Research Foundation. Lyonnaise des Eaux, and water research commission of South Africa. Water Treatment Membrane Process (1996), McGraw-Hill, New York
    • (1996) Water Treatment Membrane Process
  • 4
    • 0038541943 scopus 로고    scopus 로고
    • Monitoring the integrity of low-pressure water treatment membranes
    • Farahbakhsh K., Adham S.S., and Smith D.W. Monitoring the integrity of low-pressure water treatment membranes. J. AWWA 95 6 (2003) 95-107
    • (2003) J. AWWA , vol.95 , Issue.6 , pp. 95-107
    • Farahbakhsh, K.1    Adham, S.S.2    Smith, D.W.3
  • 5
    • 0031272979 scopus 로고    scopus 로고
    • Assessment of a particle counting method for hollow fiber membrane integrity
    • Glucina K., Do-Quang Z., and Lanine J.M. Assessment of a particle counting method for hollow fiber membrane integrity. Desalination 113 (1997) 183-187
    • (1997) Desalination , vol.113 , pp. 183-187
    • Glucina, K.1    Do-Quang, Z.2    Lanine, J.M.3
  • 6
    • 0038542003 scopus 로고    scopus 로고
    • Membrane integrity monitoring with distributed laser turbidimetry
    • Carr M.C., Carlson K.H., and Sadar M. Membrane integrity monitoring with distributed laser turbidimetry. J. AWWA 95 6 (2003) 83-94
    • (2003) J. AWWA , vol.95 , Issue.6 , pp. 83-94
    • Carr, M.C.1    Carlson, K.H.2    Sadar, M.3
  • 7
    • 34548032352 scopus 로고    scopus 로고
    • Membrane bioreactor technology for the treatment of greywater from a sports and leisure club
    • Merz C., Scheumann R., Hamouri B.E., and Kraume M. Membrane bioreactor technology for the treatment of greywater from a sports and leisure club. Desalination 215 (2007) 37-43
    • (2007) Desalination , vol.215 , pp. 37-43
    • Merz, C.1    Scheumann, R.2    Hamouri, B.E.3    Kraume, M.4
  • 8
    • 0030239364 scopus 로고    scopus 로고
    • A validatible porosimetric technique for verifying the integrity of virus-retentive membranes
    • Phillips M.W., and DiLeo A.J. A validatible porosimetric technique for verifying the integrity of virus-retentive membranes. Biologicals 24 (1996) 243-253
    • (1996) Biologicals , vol.24 , pp. 243-253
    • Phillips, M.W.1    DiLeo, A.J.2
  • 9
    • 0031277862 scopus 로고    scopus 로고
    • Automatic monitoring of membrane integrity in microfiltration system
    • Johnson W.T. Automatic monitoring of membrane integrity in microfiltration system. Desalination 113 (1997) 303-307
    • (1997) Desalination , vol.113 , pp. 303-307
    • Johnson, W.T.1
  • 10
    • 0347132373 scopus 로고    scopus 로고
    • Experiences in integrity testing ultrafiltration membranes at a large potable water treatment works
    • Oxtoby S. Experiences in integrity testing ultrafiltration membranes at a large potable water treatment works. Water Sci. Tech.: Water Supply 3 (2003) 1-7
    • (2003) Water Sci. Tech.: Water Supply , vol.3 , pp. 1-7
    • Oxtoby, S.1
  • 11
    • 48349109918 scopus 로고    scopus 로고
    • J. Phattaranawik, A.G. Fane, F.S. Wong, Detection apparatus and method utilizing membranes and ratio of transmembrane pressures, PCT/SG2007/000130, WO/2007/129994, Filing date 10 May 2007 (provisional version filed in May 2006).
    • J. Phattaranawik, A.G. Fane, F.S. Wong, Detection apparatus and method utilizing membranes and ratio of transmembrane pressures, PCT/SG2007/000130, WO/2007/129994, Filing date 10 May 2007 (provisional version filed in May 2006).
  • 12
    • 0028989296 scopus 로고
    • Critical flux concept for microfiltration fouling
    • Field R.W., Wu D., Howell J.A., and Gupta B.B. Critical flux concept for microfiltration fouling. J. Membr. Sci. 100 (1995) 259-272
    • (1995) J. Membr. Sci. , vol.100 , pp. 259-272
    • Field, R.W.1    Wu, D.2    Howell, J.A.3    Gupta, B.B.4
  • 13
    • 0028972334 scopus 로고
    • Sub-critical flux operation of microfiltration
    • Howell J.A. Sub-critical flux operation of microfiltration. J. Membr. Sci. 107 (1995) 165-171
    • (1995) J. Membr. Sci. , vol.107 , pp. 165-171
    • Howell, J.A.1
  • 14
    • 0038694756 scopus 로고    scopus 로고
    • An assessment of the Silt Density Index for RO membrane colloidal fouling experiments with iron oxide particles
    • Yiantios S.G., and Karabelas A.J. An assessment of the Silt Density Index for RO membrane colloidal fouling experiments with iron oxide particles. Desalination 151 (2002) 229-238
    • (2002) Desalination , vol.151 , pp. 229-238
    • Yiantios, S.G.1    Karabelas, A.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.