메뉴 건너뛰기




Volumn 25, Issue 4, 2009, Pages 172-180

Simulation studies on the effect of absorbers on dose distribution in rotational radiotherapy

Author keywords

Beam shaping; Dose calculation; Lead substitute; Monte Carlo simulation; Rotational radiotherapy; Shielding block

Indexed keywords

LEAD; POLYMER;

EID: 71549160390     PISSN: 11201797     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ejmp.2008.12.001     Document Type: Article
Times cited : (2)

References (15)
  • 1
    • 4544255455 scopus 로고    scopus 로고
    • Conformal Rotation Therapy with central axis beam block is a feasible alternative to Intensity-modulated radiotherapy for chordomas of the cervical spine
    • Jena R., Luhana F., Brooke S.L., Geater A.R., Jefferies S.J., Burton K.E., et al. Conformal Rotation Therapy with central axis beam block is a feasible alternative to Intensity-modulated radiotherapy for chordomas of the cervical spine. Clin Oncol 16 (2004) 449-456
    • (2004) Clin Oncol , vol.16 , pp. 449-456
    • Jena, R.1    Luhana, F.2    Brooke, S.L.3    Geater, A.R.4    Jefferies, S.J.5    Burton, K.E.6
  • 2
    • 0033867572 scopus 로고    scopus 로고
    • Intensity modulated arc therapy (IMAT) with centrally blocked rotational fields
    • Cotrutz C., Kappas C., and Webb S. Intensity modulated arc therapy (IMAT) with centrally blocked rotational fields. Phys Med Biol 45 (2000) 2185-2206
    • (2000) Phys Med Biol , vol.45 , pp. 2185-2206
    • Cotrutz, C.1    Kappas, C.2    Webb, S.3
  • 4
    • 33750546029 scopus 로고    scopus 로고
    • Simulation studies of field shaping in rotational radiation therapy
    • Ivanova T., Bliznakova K., and Pallikarakis N. Simulation studies of field shaping in rotational radiation therapy. Med Phys 33 (2006) 4289-4298
    • (2006) Med Phys , vol.33 , pp. 4289-4298
    • Ivanova, T.1    Bliznakova, K.2    Pallikarakis, N.3
  • 5
    • 0023904301 scopus 로고
    • Calculation of dose in homogeneous phantoms for partially attenuated phantom beam
    • El-Khatib E.E., Podgorsak E.B., and Pla C. Calculation of dose in homogeneous phantoms for partially attenuated phantom beam. Med Phys 15 (1988) 145-150
    • (1988) Med Phys , vol.15 , pp. 145-150
    • El-Khatib, E.E.1    Podgorsak, E.B.2    Pla, C.3
  • 7
    • 9244242563 scopus 로고    scopus 로고
    • A new radiation shielding block material for radiation therapy
    • Tajiri M., Sunaoka M., Fukumura A., and Endo M. A new radiation shielding block material for radiation therapy. Med Phys 31 (2004) 3022-3023
    • (2004) Med Phys , vol.31 , pp. 3022-3023
    • Tajiri, M.1    Sunaoka, M.2    Fukumura, A.3    Endo, M.4
  • 8
    • 0019446970 scopus 로고
    • Dynamic dose shaping by gravity-oriented absorbers for total lymph node irradiation
    • Proimos B.S., and Goldson A.L. Dynamic dose shaping by gravity-oriented absorbers for total lymph node irradiation. Int J Radiat Oncol Biol Phys 7 (1981) 973-977
    • (1981) Int J Radiat Oncol Biol Phys , vol.7 , pp. 973-977
    • Proimos, B.S.1    Goldson, A.L.2
  • 9
    • 0013973865 scopus 로고
    • Beam shapers oriented by gravity in rotational therapy
    • Proimos B.S. Beam shapers oriented by gravity in rotational therapy. Radiology 87 (1966) 928-932
    • (1966) Radiology , vol.87 , pp. 928-932
    • Proimos, B.S.1
  • 10
    • 0000762173 scopus 로고
    • Monte Carlo calculation of the penetration and diffusion of fast charged particles
    • Alder B., Fernbach S., and Rotenberg M. (Eds), Academic Press, New York
    • Berger M.J. Monte Carlo calculation of the penetration and diffusion of fast charged particles. In: Alder B., Fernbach S., and Rotenberg M. (Eds). Methods in computational physics 1 (1963), Academic Press, New York 135-215
    • (1963) Methods in computational physics 1 , pp. 135-215
    • Berger, M.J.1
  • 12
    • 0028902539 scopus 로고
    • Depth dose under narrow shielding blocks: a comparison of measured and calculated dose
    • Davis J.B., and Reiner B. Depth dose under narrow shielding blocks: a comparison of measured and calculated dose. Radiother Oncol 34 (1995) 219-227
    • (1995) Radiother Oncol , vol.34 , pp. 219-227
    • Davis, J.B.1    Reiner, B.2
  • 13
    • 0031805413 scopus 로고    scopus 로고
    • On compensator design for photon beam intensity-modulated conformal therapy
    • Jiang S.B., and Ayyangar K.M. On compensator design for photon beam intensity-modulated conformal therapy. Med Phys 25 (1998) 668-675
    • (1998) Med Phys , vol.25 , pp. 668-675
    • Jiang, S.B.1    Ayyangar, K.M.2
  • 14
    • 0036130665 scopus 로고    scopus 로고
    • Monte Carlo calculation of nine megavoltage photon beam spectra using the BEAM code
    • Sheikh-Bagheri D., and Rogers D.W.O. Monte Carlo calculation of nine megavoltage photon beam spectra using the BEAM code. Med Phys 29 (2002) 391-402
    • (2002) Med Phys , vol.29 , pp. 391-402
    • Sheikh-Bagheri, D.1    Rogers, D.W.O.2
  • 15
    • 0030440153 scopus 로고    scopus 로고
    • Characteristics of secondary electrons produced by 6, 10 and 24 MV x-ray beams
    • Jursinic P.A., and Mackie T.R. Characteristics of secondary electrons produced by 6, 10 and 24 MV x-ray beams. Phys Med Biol 41 (1996) 1499-1509
    • (1996) Phys Med Biol , vol.41 , pp. 1499-1509
    • Jursinic, P.A.1    Mackie, T.R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.