메뉴 건너뛰기




Volumn , Issue , 2009, Pages 1202-1205

Implantable polycrystalline diamond neural probe for in vivo and in vitro physiological recording

Author keywords

Diamond MEMS; Neural probe and physiological recording

Indexed keywords

AG/AGCL; COUNTER ELECTRODES; DIAMOND GROWTH; ELECTRICAL RECORDING; ELECTROCHEMICAL DETECTION; ELECTROCHEMICAL RECORDING; HIGH TEMPERATURE; IN-VITRO; IN-VIVO; NEURAL PROBES; PHYSIOLOGICAL RECORDINGS; POLYCRYSTALLINE DIAMONDS; POWER REQUIREMENT; SECOND GENERATION; WORKING ELECTRODE;

EID: 71449105468     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/SENSOR.2009.5285919     Document Type: Conference Paper
Times cited : (4)

References (10)
  • 1
    • 33846920894 scopus 로고    scopus 로고
    • M. D. Johnson, R. K. Franklin, K. A. Scott, R. B. Brown and D. R. Kipke, Neural probes for concurrent detection of neurochemical and electrophysiological signals in vivo, in Proc. of IEEE EMBS, pp. 7325-7328, 2005.
    • M. D. Johnson, R. K. Franklin, K. A. Scott, R. B. Brown and D. R. Kipke, "Neural probes for concurrent detection of neurochemical and electrophysiological signals in vivo," in Proc. of IEEE EMBS, pp. 7325-7328, 2005.
  • 3
    • 33745238889 scopus 로고    scopus 로고
    • Fabrication, characterization, and application of a diamond microelectrode for electrochemical measurement of norepinephrine release from the sympathetic nervous system
    • J. Park, V. Q. Mocko, K. Peckova, J. J. Galligan, G. D. Fink and G. M. Swain, " Fabrication, characterization, and application of a diamond microelectrode for electrochemical measurement of norepinephrine release from the sympathetic nervous system," Dia. and Rel. Mat., v. 15, pp. 761-772, 2006.
    • (2006) Dia. and Rel. Mat , vol.15 , pp. 761-772
    • Park, J.1    Mocko, V.Q.2    Peckova, K.3    Galligan, J.J.4    Fink, G.D.5    Swain, G.M.6
  • 4
    • 0032677890 scopus 로고    scopus 로고
    • Electrochemical Characterization of Highly Boron-Doped Diamond Microelectrodes in Aqueous Electrolyte
    • B. V. Sarada, T. N. Rao, D. A. Tryk, A. Fujishima, Electrochemical Characterization of Highly Boron-Doped Diamond Microelectrodes in Aqueous Electrolyte," J. Electrochem. Soc., v. 146, pp. 1469-1471, 1999.
    • (1999) J. Electrochem. Soc , vol.146 , pp. 1469-1471
    • Sarada, B.V.1    Rao, T.N.2    Tryk, D.A.3    Fujishima, A.4
  • 5
    • 50149101787 scopus 로고    scopus 로고
    • Fabrication and testing of a novel all-diamond neural probe for chemical detection and electrical sensing applications
    • H. -Y. Chan, D. M. Aslam, S. Wang, G. M. Swain and K. D. Wise, "Fabrication and testing of a novel all-diamond neural probe for chemical detection and electrical sensing applications," in Proc. of Int. Conf. on MEMS, pp. 244-247, 2008.
    • (2008) Proc. of Int. Conf. on MEMS , pp. 244-247
    • Chan, H.-Y.1    Aslam, D.M.2    Wang, S.3    Swain, G.M.4    Wise, K.D.5
  • 7
    • 0036644776 scopus 로고    scopus 로고
    • Development of a micrp-planar Ag/AgCl quasi-reference electrode with long-term stability for an amperometric glucose sensor
    • T. Matsumoto, A. Ohashi and N. Ito, "Development of a micrp-planar Ag/AgCl quasi-reference electrode with long-term stability for an amperometric glucose sensor," Anal. Chim. Acta, v. 462, pp. 253-259, 2002.
    • (2002) Anal. Chim. Acta , vol.462 , pp. 253-259
    • Matsumoto, T.1    Ohashi, A.2    Ito, N.3
  • 8
    • 0000988796 scopus 로고    scopus 로고
    • Hydrophilic polyurenthane coated silver/silver chloride electrode for the determination of chloride in blood
    • J.S. Lee, S.D. Lee, G. Gui, J.J Lee, J. H. Shin, G. S. Cha and H. Nam, "Hydrophilic polyurenthane coated silver/silver chloride electrode for the determination of chloride in blood," Electroanalysis, v. 11, pp. 260-267, 1999.
    • (1999) Electroanalysis , vol.11 , pp. 260-267
    • Lee, J.S.1    Lee, S.D.2    Gui, G.3    Lee, J.J.4    Shin, J.H.5    Cha, G.S.6    Nam, H.7
  • 9
    • 0037811248 scopus 로고    scopus 로고
    • Improvement of integrated Ag/AgCl thin-film electrodes by KCL-gel coating for ISFET applications
    • L. Y. Huang, R. S. Huang and L. H. Lo, "Improvement of integrated Ag/AgCl thin-film electrodes by KCL-gel coating for ISFET applications, "Sensors and Actuators B, v. 94, pp. 53-64, 2003.
    • (2003) Sensors and Actuators B , vol.94 , pp. 53-64
    • Huang, L.Y.1    Huang, R.S.2    Lo, L.H.3
  • 10
    • 0000720053 scopus 로고    scopus 로고
    • M. A Nolan, S. H. Tan and S. P. Kounaves, Fabrication and characterization of a solid state reference electrode for electroanalysis of natural waters with ultramicroelectrode, Anal. Chem., v. 69, pp. 1244-1247, 1997.
    • M. A Nolan, S. H. Tan and S. P. Kounaves, "Fabrication and characterization of a solid state reference electrode for electroanalysis of natural waters with ultramicroelectrode," Anal. Chem., v. 69, pp. 1244-1247, 1997.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.