메뉴 건너뛰기




Volumn 25, Issue 6, 2009, Pages 795-801

Mechanical formula for the plastic limit pressure of stent during expansion

Author keywords

Expansion; FEM; Inter force; Plastic limit pressure; Stent

Indexed keywords

AXIAL FORCES; CARDIOVASCULAR STENTS; FEM; GEOMETRICAL PARAMETERS; INTER FORCE; MATERIAL PARAMETER; PLASTIC LIMIT; THEORETICAL MODELS;

EID: 71249143884     PISSN: 05677718     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10409-009-0298-7     Document Type: Article
Times cited : (7)

References (13)
  • 1
    • 0034930155 scopus 로고    scopus 로고
    • Mechanical properties of coronary stents determined by using finite element analysis
    • DOI 10.1016/S0021-9290(01)00026-4, PII S0021929001000264
    • F. Etave G. Finet M. Boivin J. Boyer G. Rioufol G. Thollet 2001 Mechanical property of coronary stents determined by using finite element analysis J. Biomech. 34 1065 1075 10.1016/S0021-9290(01)00026-4 (Pubitemid 32633776)
    • (2001) Journal of Biomechanics , vol.34 , Issue.8 , pp. 1065-1075
    • Etave, F.1    Finet, G.2    Boivin, M.3    Boyer, J.-C.4    Rioufol, G.5    Thollet, G.6
  • 2
    • 0036000226 scopus 로고    scopus 로고
    • Mechanical behavior of coronary stents investigated through the finite element method
    • DOI 10.1016/S0021-9290(02)00033-7, PII S0021929002000337
    • F. Migliavacca L. Petrini M. Colombo F. Auricchio 2002 Mechanical behavior of coronary stents investigated through the finite element method J. Biomech. 35 803 811 10.1016/S0021-9290(02)00033-7 (Pubitemid 34518378)
    • (2002) Journal of Biomechanics , vol.35 , Issue.6 , pp. 803-811
    • Migliavacca, F.1    Petrini, L.2    Colombo, M.3    Auricchio, F.4    Pietrabissa, R.5
  • 3
    • 10444258936 scopus 로고    scopus 로고
    • A predictive study of the mechanical behaviour of coronary stents by computer modelling
    • DOI 10.1016/j.medengphy.2004.08.012, PII S1350453304001444
    • F. Migliavacca L. Petrini V. Montanari I. Quagliana F. Auricchio G. Dubini 2005 A predictive study of the mechanical behaviour of coronary stents by computer modeling Med. Eng. Phys. 27 13 18 10.1016/j.medengphy.2004.08.012 (Pubitemid 39643159)
    • (2005) Medical Engineering and Physics , vol.27 , Issue.1 , pp. 13-18
    • Migliavacca, F.1    Petrini, L.2    Montanari, V.3    Quagliana, I.4    Auricchio, F.5    Dubini, G.6
  • 4
    • 20444475661 scopus 로고    scopus 로고
    • Cardiovascular stent design and vessel stresses: A finite element analysis
    • DOI 10.1016/j.jbiomech.2004.07.022, PII S0021929004003756
    • C. Lally F. Dolan P.J. Prendergast 2005 Cardiovascular stent design and vessel stresses: a finite element analysis J. Biomech. 38 1574 1581 10.1016/j.jbiomech.2004.07.022 (Pubitemid 40813479)
    • (2005) Journal of Biomechanics , vol.38 , Issue.8 , pp. 1574-1581
    • Lally, C.1    Dolan, F.2    Prendergast, P.J.3
  • 5
    • 0242608330 scopus 로고    scopus 로고
    • Finite element simulation of stent and balloon interaction
    • 10.1016/S0924-0136(03)00435-7
    • S.N.D. Chua B.J. MacDonald M.S.J. Hashmi 2003 Finite element simulation of stent and balloon interaction J. Mater. Proc. Technol. 143 591 597 10.1016/S0924-0136(03)00435-7
    • (2003) J. Mater. Proc. Technol. , vol.143 , pp. 591-597
    • Chua, S.N.D.1    MacDonald, B.J.2    Hashmi, M.S.J.3
  • 6
    • 10044294743 scopus 로고    scopus 로고
    • Effects of varying slotted tube (stent) geometry on its expansion behaviour using finite element method
    • 10.1016/j.jmatprotec.2004.04.395
    • S.N.D. Chua B.J. MacDonald M.S.J. Hashmi 2004 Effects of varying slotted tube (stent) geometry on its expansion behaviour using finite element method J. Mater. Proc. Technol. 155 1764 1771 10.1016/j.jmatprotec.2004.04.395
    • (2004) J. Mater. Proc. Technol. , vol.155 , pp. 1764-1771
    • Chua, S.N.D.1    MacDonald, B.J.2    Hashmi, M.S.J.3
  • 7
    • 27744557004 scopus 로고    scopus 로고
    • Analysis of the transient expansion behavior and design optimization of coronary stents by finite element method
    • DOI 10.1016/j.jbiomech.2004.11.003, PII S0021929004005378
    • W. Wang D. Liang D. Yang M. Qi 2006 Analysis of the transient expansion behavior and design optimization of coronary stents by finite element method J. Biomech. 39 21 32 10.1016/j.jbiomech.2004.11.003 (Pubitemid 41585005)
    • (2006) Journal of Biomechanics , vol.39 , Issue.1 , pp. 21-32
    • Wang, W.-Q.1    Liang, D.-K.2    Yang, D.-Z.3    Qi, M.4
  • 8
    • 35048821562 scopus 로고    scopus 로고
    • On the finite element modelling of balloon-expandable stents
    • DOI 10.1016/j.jmbbm.2007.07.002, PII S1751616107000136
    • J. Feng Z.H. Xia K. Sasaki 2008 On the finite element modelling of balloon-expandable stents J. Mechan. Behav. Biomed. Mater. 1 86 95 10.1016/j.jmbbm.2007.07.002 (Pubitemid 47557534)
    • (2008) Journal of the Mechanical Behavior of Biomedical Materials , vol.1 , Issue.1 , pp. 86-95
    • Ju, F.1    Xia, Z.2    Sasaki, K.3
  • 9
    • 34147173952 scopus 로고    scopus 로고
    • A general finite element analysis method for balloon expandable stents based on repeated unit cell (RUC) model
    • DOI 10.1016/j.finel.2007.01.001, PII S0168874X07000054
    • Z. Xia F. Ju K. Sasaki 2007 A general finite element analysis method for balloon expandable stents based on Repeated Unit Cell (RUC) model Finite Elem. Anal. Des. 43 649 658 10.1016/j.finel.2007.01.001 (Pubitemid 46560173)
    • (2007) Finite Elements in Analysis and Design , vol.43 , Issue.8 , pp. 649-658
    • Xia, Z.1    Ju, F.2    Sasaki, K.3
  • 10
    • 38349062270 scopus 로고    scopus 로고
    • Realistic finite element-based stent design: The impact of balloon folding
    • 10.1016/j.jbiomech.2007.08.014
    • M. De Beule P. Mortier S.G. Carlier B. Verhegghe R. Van Impe P. Verdonck 2008 Realistic finite element-based stent design: the impact of balloon folding J. Biomech. 41 383 389 10.1016/j.jbiomech.2007.08.014
    • (2008) J. Biomech. , vol.41 , pp. 383-389
    • De Beule, M.1    Mortier, P.2    Carlier, S.G.3    Verhegghe, B.4    Van Impe, R.5    Verdonck, P.6
  • 11
    • 0034333737 scopus 로고    scopus 로고
    • Mechanical behaviour modelling of balloon-expandable stents
    • DOI 10.1016/S0021-9290(00)00098-1, PII S0021929000000981
    • C. Dumoulin B. Cochelin 2000 Mechanical behaviour modeling of balloon-expandable stents J. Biomech. 33 1461 1470 10.1016/S0021-9290(00)00098-1 (Pubitemid 30625104)
    • (2000) Journal of Biomechanics , vol.33 , Issue.11 , pp. 1461-1470
    • Dumoulin, C.1    Cochelin, B.2
  • 12
    • 0027567438 scopus 로고
    • A study of the geometrical and mechanical properties of a self-expanding metallic stent-theory and experiment
    • 10.1002/jab.770040111
    • M.R. Jedwab C.O. Clerc 1993 A study of the geometrical and mechanical properties of a self-expanding metallic stent-theory and experiment J. Appl. Biomater. 4 77 85 10.1002/jab.770040111
    • (1993) J. Appl. Biomater. , vol.4 , pp. 77-85
    • Jedwab, M.R.1    Clerc, C.O.2
  • 13
    • 0001838073 scopus 로고
    • Influence of axial force on the elastic-plastic bending and springback of a beam
    • 10.1016/0378-3804(82)90016-X
    • T.X. Yu W. Johnson 1982 Influence of axial force on the elastic-plastic bending and springback of a beam J. Mech. Work. Technol. 6 5 21 10.1016/0378-3804(82)90016-X
    • (1982) J. Mech. Work. Technol. , vol.6 , pp. 5-21
    • Yu, T.X.1    Johnson, W.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.