메뉴 건너뛰기




Volumn 34, Issue 10, 2009, Pages 1851-1858

Biomechanical Comparison of Double-Row Locking Plates Versus Single- and Double-Row Non-Locking Plates in a Comminuted Metacarpal Fracture Model

Author keywords

comminuted; fracture; locking; Metacarpal; plate

Indexed keywords

ARTICLE; BIOMECHANICS; BONE SCREW; COMMINUTED FRACTURE; COMPRESSIVE STRENGTH; CONTROLLED STUDY; INTERMETHOD COMPARISON; METACARPAL BONE; METACARPAL BONE FRACTURE; PLATE FIXATION; PRIORITY JOURNAL; RIGIDITY; SIMULATION; SURGICAL TECHNIQUE; TORQUE; TORSION;

EID: 71149105299     PISSN: 03635023     EISSN: 15316564     Source Type: Journal    
DOI: 10.1016/j.jhsa.2009.07.005     Document Type: Article
Times cited : (37)

References (44)
  • 1
    • 33747872651 scopus 로고    scopus 로고
    • Locked intramedullary nailing of metacarpal fractures secondary to gunshot wounds
    • Bach H.G., Gonzalez M.H., and Hall Jr. R.F. Locked intramedullary nailing of metacarpal fractures secondary to gunshot wounds. J Hand Surg 31A (2006) 1083-1087
    • (2006) J Hand Surg , vol.31 A , pp. 1083-1087
    • Bach, H.G.1    Gonzalez, M.H.2    Hall Jr., R.F.3
  • 2
    • 0027360136 scopus 로고
    • Comparative fatigue strengths and stabilities of metacarpal internal fixation techniques
    • Firoozbakhsh K.K., Moneim M.S., Howey T., Castaneda E., and Pirela-Cruz M.A. Comparative fatigue strengths and stabilities of metacarpal internal fixation techniques. J Hand Surg 18A (1993) 1059-1068
    • (1993) J Hand Surg , vol.18 A , pp. 1059-1068
    • Firoozbakhsh, K.K.1    Moneim, M.S.2    Howey, T.3    Castaneda, E.4    Pirela-Cruz, M.A.5
  • 3
    • 0023634443 scopus 로고
    • Fractures of the metacarpals: treatment by AO screw and plate fixation
    • Ford D.J., el-Hadidi S., Lunn P.G., and Burke F.D. Fractures of the metacarpals: treatment by AO screw and plate fixation. J Hand Surg 12B (1987) 34-37
    • (1987) J Hand Surg , vol.12 B , pp. 34-37
    • Ford, D.J.1    el-Hadidi, S.2    Lunn, P.G.3    Burke, F.D.4
  • 4
    • 0029060556 scopus 로고
    • Flexible intramedullary nailing for metacarpal fractures
    • Gonzalez M.H., Igram C.M., and Hall Jr. R.F. Flexible intramedullary nailing for metacarpal fractures. J Hand Surg 20A (1995) 382-387
    • (1995) J Hand Surg , vol.20 A , pp. 382-387
    • Gonzalez, M.H.1    Igram, C.M.2    Hall Jr., R.F.3
  • 5
    • 20944433073 scopus 로고    scopus 로고
    • Intramedullary nailing of metacarpal shaft fractures
    • Orbay J. Intramedullary nailing of metacarpal shaft fractures. Tech Hand Up Extrem Surg 9 (2005) 69-73
    • (2005) Tech Hand Up Extrem Surg , vol.9 , pp. 69-73
    • Orbay, J.1
  • 6
    • 0029123276 scopus 로고
    • Comparative biomechanical stability of titanium bone fixation systems in metacarpal fractures
    • Prevel C.D., McCarty M., Katona T., Moore K., Jackson J.R., Eppley B.L., et al. Comparative biomechanical stability of titanium bone fixation systems in metacarpal fractures. Ann Plast Surg 35 (1995) 6-14
    • (1995) Ann Plast Surg , vol.35 , pp. 6-14
    • Prevel, C.D.1    McCarty, M.2    Katona, T.3    Moore, K.4    Jackson, J.R.5    Eppley, B.L.6
  • 8
    • 0036738361 scopus 로고    scopus 로고
    • Self-reinforced bioabsorbable versus metallic fixation systems for metacarpal and phalangeal fractures: a biomechanical study
    • Waris E., Ashammakhi N., Raatikainen T., Tormala P., Santavirta S., and Konttinen Y.T. Self-reinforced bioabsorbable versus metallic fixation systems for metacarpal and phalangeal fractures: a biomechanical study. J Hand Surg 27A (2002) 902-909
    • (2002) J Hand Surg , vol.27 A , pp. 902-909
    • Waris, E.1    Ashammakhi, N.2    Raatikainen, T.3    Tormala, P.4    Santavirta, S.5    Konttinen, Y.T.6
  • 9
    • 2542522178 scopus 로고    scopus 로고
    • Plating of metacarpal fractures: unicortical or bicortical screws?
    • Dona E., Gillie R.M., Gianoutsos M.P., and Walsh W.R. Plating of metacarpal fractures: unicortical or bicortical screws?. J Hand Surg 29B (2004) 218-221
    • (2004) J Hand Surg , vol.29 B , pp. 218-221
    • Dona, E.1    Gillie, R.M.2    Gianoutsos, M.P.3    Walsh, W.R.4
  • 10
    • 0028870062 scopus 로고
    • Mini and micro plating of phalangeal and metacarpal fractures: a biomechanical study
    • Prevel C.D., Eppley B.L., Jackson J.R., Moore K., McCarty M., Sood R., et al. Mini and micro plating of phalangeal and metacarpal fractures: a biomechanical study. J Hand Surg 20A (1995) 44-49
    • (1995) J Hand Surg , vol.20 A , pp. 44-49
    • Prevel, C.D.1    Eppley, B.L.2    Jackson, J.R.3    Moore, K.4    McCarty, M.5    Sood, R.6
  • 12
    • 0029964136 scopus 로고    scopus 로고
    • Internal fixation of oblique metacarpal fractures: a biomechanical evaluation by impact loading
    • Firoozbakhsh K.K., Moneim M.S., Doherty W., and Naraghi F.F. Internal fixation of oblique metacarpal fractures: a biomechanical evaluation by impact loading. Clin Orthop Relat Res 325 (1996) 296-301
    • (1996) Clin Orthop Relat Res , vol.325 , pp. 296-301
    • Firoozbakhsh, K.K.1    Moneim, M.S.2    Doherty, W.3    Naraghi, F.F.4
  • 13
    • 0022283277 scopus 로고
    • A quantitative comparison of metacarpal fracture stability with five different methods of internal fixation
    • Mann R.J., Black D., Constine R., and Daniels A.U. A quantitative comparison of metacarpal fracture stability with five different methods of internal fixation. J Hand Surg 10A (1985) 1024-1028
    • (1985) J Hand Surg , vol.10 A , pp. 1024-1028
    • Mann, R.J.1    Black, D.2    Constine, R.3    Daniels, A.U.4
  • 14
    • 0022624138 scopus 로고
    • Fixation of metacarpal and phalangeal fractures with miniature plates and screws
    • Dabezies E.J., and Schutte J.P. Fixation of metacarpal and phalangeal fractures with miniature plates and screws. J Hand Surg 11A (1986) 283-288
    • (1986) J Hand Surg , vol.11 A , pp. 283-288
    • Dabezies, E.J.1    Schutte, J.P.2
  • 15
    • 0018744248 scopus 로고
    • Tendon rupture as a complication of screw fixation in fractures in the hand: a case report
    • Fambrough R.A., and Green D.P. Tendon rupture as a complication of screw fixation in fractures in the hand: a case report. J Bone Joint Surg 61A (1979) 781-782
    • (1979) J Bone Joint Surg , vol.61 A , pp. 781-782
    • Fambrough, R.A.1    Green, D.P.2
  • 16
    • 0023133412 scopus 로고
    • Complications of plate fixation in the hand skeleton
    • Stern P.J., Wieser M.J., and Reilly D.G. Complications of plate fixation in the hand skeleton. Clin Orthop Relat Res 214 (1987) 59-65
    • (1987) Clin Orthop Relat Res , vol.214 , pp. 59-65
    • Stern, P.J.1    Wieser, M.J.2    Reilly, D.G.3
  • 18
    • 2642514242 scopus 로고    scopus 로고
    • A biomechanical evaluation of methods of distal humerus fracture fixation using locking compression plates versus conventional reconstruction plates
    • Korner J., Diederichs G., Arzdorf M., Lill H., Josten C., Schneider E., et al. A biomechanical evaluation of methods of distal humerus fracture fixation using locking compression plates versus conventional reconstruction plates. J Orthop Trauma 18 (2004) 286-293
    • (2004) J Orthop Trauma , vol.18 , pp. 286-293
    • Korner, J.1    Diederichs, G.2    Arzdorf, M.3    Lill, H.4    Josten, C.5    Schneider, E.6
  • 19
    • 33644645688 scopus 로고    scopus 로고
    • Biomechanical stability of a fixed-angle volar plate versus fragment-specific fixation system: cyclic testing in a C2-type distal radius cadaver fracture model
    • Taylor K.F., Parks B.G., and Segalman K.A. Biomechanical stability of a fixed-angle volar plate versus fragment-specific fixation system: cyclic testing in a C2-type distal radius cadaver fracture model. J Hand Surg 31A (2006) 373-381
    • (2006) J Hand Surg , vol.31 A , pp. 373-381
    • Taylor, K.F.1    Parks, B.G.2    Segalman, K.A.3
  • 21
    • 34248153658 scopus 로고    scopus 로고
    • Fatigue behavior of Ilizarov frame versus tibial interlocking nail in a comminuted tibial fracture model: a biomechanical study
    • Hasenboehler E., Smith W.R., Laudicina L., Philips G.C., Stahel P.F., and Morgan S.J. Fatigue behavior of Ilizarov frame versus tibial interlocking nail in a comminuted tibial fracture model: a biomechanical study. J Orthop Surg 1 (2006) 16
    • (2006) J Orthop Surg , vol.1 , pp. 16
    • Hasenboehler, E.1    Smith, W.R.2    Laudicina, L.3    Philips, G.C.4    Stahel, P.F.5    Morgan, S.J.6
  • 22
    • 33750802999 scopus 로고    scopus 로고
    • Internal fixation of dorsally displaced fractures of the distal part of the radius: a biomechanical analysis of volar plate fracture stability
    • Willis A.A., Kutsumi K., Zobitz M.E., and Cooney III W.P. Internal fixation of dorsally displaced fractures of the distal part of the radius: a biomechanical analysis of volar plate fracture stability. J Bone Joint Surg 88A (2006) 2411-2417
    • (2006) J Bone Joint Surg , vol.88 A , pp. 2411-2417
    • Willis, A.A.1    Kutsumi, K.2    Zobitz, M.E.3    Cooney III, W.P.4
  • 23
    • 54149109355 scopus 로고    scopus 로고
    • Fractures of the proximal phalanx and metacarpals in the hand: preferred methods of stabilization
    • Henry M.H. Fractures of the proximal phalanx and metacarpals in the hand: preferred methods of stabilization. J Am Acad Orthop Surg 16 (2008) 586-595
    • (2008) J Am Acad Orthop Surg , vol.16 , pp. 586-595
    • Henry, M.H.1
  • 24
    • 41849086954 scopus 로고    scopus 로고
    • Minimally invasive intramedullary rod fixation of multiple metacarpal shaft fractures
    • Balfour G.W. Minimally invasive intramedullary rod fixation of multiple metacarpal shaft fractures. Tech Hand Up Extrem Surg 12 (2008) 43-45
    • (2008) Tech Hand Up Extrem Surg , vol.12 , pp. 43-45
    • Balfour, G.W.1
  • 25
    • 57149127378 scopus 로고    scopus 로고
    • Comparison of intramedullary nailing versus plate-screw fixation of extra-articular metacarpal fractures
    • Ozer K., Gillani S., Williams A., Peterson S.L., and Morgan S. Comparison of intramedullary nailing versus plate-screw fixation of extra-articular metacarpal fractures. J Hand Surg 33A (2008) 1724-1731
    • (2008) J Hand Surg , vol.33 A , pp. 1724-1731
    • Ozer, K.1    Gillani, S.2    Williams, A.3    Peterson, S.L.4    Morgan, S.5
  • 26
    • 0034207664 scopus 로고    scopus 로고
    • Biomechanical evaluation of the dynamic hip screw with two- and four-hole side plates
    • McLoughlin S.W., Wheeler D.L., Rider J., and Bolhofner B. Biomechanical evaluation of the dynamic hip screw with two- and four-hole side plates. J Orthop Trauma 14 (2000) 318-323
    • (2000) J Orthop Trauma , vol.14 , pp. 318-323
    • McLoughlin, S.W.1    Wheeler, D.L.2    Rider, J.3    Bolhofner, B.4
  • 27
    • 33748678699 scopus 로고    scopus 로고
    • A short plate compression screw with diagonal bolts: a biomechanical evaluation performed experimentally and by numerical computation
    • Peleg E., Mosheiff R., Liebergall M., and Mattan Y. A short plate compression screw with diagonal bolts: a biomechanical evaluation performed experimentally and by numerical computation. Clin Biomech 21 (2006) 963-968
    • (2006) Clin Biomech , vol.21 , pp. 963-968
    • Peleg, E.1    Mosheiff, R.2    Liebergall, M.3    Mattan, Y.4
  • 28
    • 0029692879 scopus 로고    scopus 로고
    • The strength of plate fixation in relation to the number and spacing of bone screws
    • Tornkvist H., Hearn T.C., and Schatzker J. The strength of plate fixation in relation to the number and spacing of bone screws. J Orthop Trauma 10 (1996) 204-208
    • (1996) J Orthop Trauma , vol.10 , pp. 204-208
    • Tornkvist, H.1    Hearn, T.C.2    Schatzker, J.3
  • 29
    • 0029931129 scopus 로고    scopus 로고
    • Use of the minicondylar plate in metacarpal and phalangeal fractures
    • Ouellette E.A., and Freeland A.E. Use of the minicondylar plate in metacarpal and phalangeal fractures. Clin Orthop Relat Res 327 (1996) 38-46
    • (1996) Clin Orthop Relat Res , vol.327 , pp. 38-46
    • Ouellette, E.A.1    Freeland, A.E.2
  • 30
    • 0032463393 scopus 로고    scopus 로고
    • Complications and range of motion following plate fixation of metacarpal and phalangeal fractures
    • Page S.M., and Stern P.J. Complications and range of motion following plate fixation of metacarpal and phalangeal fractures. J Hand Surg 23A (1998) 827-832
    • (1998) J Hand Surg , vol.23 A , pp. 827-832
    • Page, S.M.1    Stern, P.J.2
  • 31
    • 33846590572 scopus 로고    scopus 로고
    • Early controlled passive motion improves early fracture alignment and structural properties in a closed extra-articular metacarpal fracture in a rabbit model
    • Feehan L.M., Tang C.S., and Oxland T.R. Early controlled passive motion improves early fracture alignment and structural properties in a closed extra-articular metacarpal fracture in a rabbit model. J Hand Surg 32A (2007) 200-208
    • (2007) J Hand Surg , vol.32 A , pp. 200-208
    • Feehan, L.M.1    Tang, C.S.2    Oxland, T.R.3
  • 33
    • 34247585543 scopus 로고    scopus 로고
    • Mechanical characteristics of locking and compression plate constructs applied dorsally to distal radius fractures
    • Boswell S., McIff T.E., Trease C.A., and Toby E.B. Mechanical characteristics of locking and compression plate constructs applied dorsally to distal radius fractures. J Hand Surg 32A (2007) 623-629
    • (2007) J Hand Surg , vol.32 A , pp. 623-629
    • Boswell, S.1    McIff, T.E.2    Trease, C.A.3    Toby, E.B.4
  • 34
    • 33646477698 scopus 로고    scopus 로고
    • Fixation of diaphyseal fractures with a segmental defect: a biomechanical comparison of locked and conventional plating techniques
    • Fulkerson E., Egol K.A., Kubiak E.N., Liporace F., Kummer F.J., and Koval K.J. Fixation of diaphyseal fractures with a segmental defect: a biomechanical comparison of locked and conventional plating techniques. J Trauma 60 (2006) 830-835
    • (2006) J Trauma , vol.60 , pp. 830-835
    • Fulkerson, E.1    Egol, K.A.2    Kubiak, E.N.3    Liporace, F.4    Kummer, F.J.5    Koval, K.J.6
  • 35
    • 52649125805 scopus 로고    scopus 로고
    • The changing face of orthopaedic trauma: locked plating and minimally invasive techniques
    • Tejwani N.C., and Wolinsky P. The changing face of orthopaedic trauma: locked plating and minimally invasive techniques. Instr Course Lect 57 (2008) 3-9
    • (2008) Instr Course Lect , vol.57 , pp. 3-9
    • Tejwani, N.C.1    Wolinsky, P.2
  • 36
    • 33847727840 scopus 로고    scopus 로고
    • Locking plate technology: current concepts
    • Greiwe R.M., and Archdeacon M.T. Locking plate technology: current concepts. J Knee Surg 20 (2007) 50-55
    • (2007) J Knee Surg , vol.20 , pp. 50-55
    • Greiwe, R.M.1    Archdeacon, M.T.2
  • 37
    • 53849144285 scopus 로고    scopus 로고
    • A revolution in the management of fractures of the distal radius?
    • Downing N.D., and Karantana A. A revolution in the management of fractures of the distal radius?. J Bone Joint Surg 90B (2008) 1271-1275
    • (2008) J Bone Joint Surg , vol.90 B , pp. 1271-1275
    • Downing, N.D.1    Karantana, A.2
  • 38
    • 22544465252 scopus 로고    scopus 로고
    • Biomechanics and biology of plate fixation of distal radius fractures
    • Freeland A.E., and Luber K.T. Biomechanics and biology of plate fixation of distal radius fractures. Hand Clin 21 (2005) 329-339
    • (2005) Hand Clin , vol.21 , pp. 329-339
    • Freeland, A.E.1    Luber, K.T.2
  • 39
    • 40649090387 scopus 로고    scopus 로고
    • Distal radius fracture management in elderly patients: a literature review
    • Gehrmann S.V., Windolf J., and Kaufmann R.A. Distal radius fracture management in elderly patients: a literature review. J Hand Surg 33A (2008) 421-429
    • (2008) J Hand Surg , vol.33 A , pp. 421-429
    • Gehrmann, S.V.1    Windolf, J.2    Kaufmann, R.A.3
  • 40
    • 58149128001 scopus 로고    scopus 로고
    • Biology versus mechanics in the treatment of distal radial fractures
    • Keast-Butler O., and Schemitsch E.H. Biology versus mechanics in the treatment of distal radial fractures. J Orthop Trauma 22 (2008) S91-S95
    • (2008) J Orthop Trauma , vol.22
    • Keast-Butler, O.1    Schemitsch, E.H.2
  • 41
    • 34249708441 scopus 로고    scopus 로고
    • Locking plate technology and its applications in upper extremity fracture care
    • Larson A.N., and Rizzo M. Locking plate technology and its applications in upper extremity fracture care. Hand Clin 23 (2007) 269-278
    • (2007) Hand Clin , vol.23 , pp. 269-278
    • Larson, A.N.1    Rizzo, M.2
  • 42
    • 58649101626 scopus 로고    scopus 로고
    • Relative stability of conventional and locked plating fixation in a model of the osteoporotic femoral diaphysis
    • Fitzpatrick D.C., Doornink J., Madey S.M., and Bottlang M. Relative stability of conventional and locked plating fixation in a model of the osteoporotic femoral diaphysis. Clin Biomech 24 (2009) 203-209
    • (2009) Clin Biomech , vol.24 , pp. 203-209
    • Fitzpatrick, D.C.1    Doornink, J.2    Madey, S.M.3    Bottlang, M.4
  • 43
    • 0032872213 scopus 로고    scopus 로고
    • Low-profile versus conventional metacarpal plating systems: a comparison of construct stiffness and strength
    • Fischer K.J., Bastidas J.A., Provenzano D.A., and Tomaino M.M. Low-profile versus conventional metacarpal plating systems: a comparison of construct stiffness and strength. J Hand Surg 24A (1999) 928-934
    • (1999) J Hand Surg , vol.24 A , pp. 928-934
    • Fischer, K.J.1    Bastidas, J.A.2    Provenzano, D.A.3    Tomaino, M.M.4
  • 44
    • 62549115765 scopus 로고    scopus 로고
    • A nonlocking end screw can decrease fracture risk caused by locked plating in the osteoporotic diaphysis
    • Bottlang M., Doornink J., Byrd G.D., Fitzpatrick D.C., and Madey S.M. A nonlocking end screw can decrease fracture risk caused by locked plating in the osteoporotic diaphysis. J Bone Joint Surg 91A (2009) 620-627
    • (2009) J Bone Joint Surg , vol.91 A , pp. 620-627
    • Bottlang, M.1    Doornink, J.2    Byrd, G.D.3    Fitzpatrick, D.C.4    Madey, S.M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.