메뉴 건너뛰기




Volumn 325, Issue , 1996, Pages 296-301

Internal fixation of oblique metacarpal fractures: A biomechanical evaluation by impact loading

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; BIOMECHANICS; BONE SCREW; HUMAN; HUMAN CELL; HUMAN TISSUE; INTRAMEDULLARY NAILING; KIRSCHNER WIRE; METACARPAL BONE FRACTURE; OSTEOSYNTHESIS; OSTEOTOMY; PRIORITY JOURNAL; SUPERIOR OBLIQUE MUSCLE;

EID: 0029964136     PISSN: 0009921X     EISSN: 15281132     Source Type: Journal    
DOI: 10.1097/00003086-199604000-00036     Document Type: Article
Times cited : (20)

References (14)
  • 1
    • 9244244317 scopus 로고
    • Ligamentous disruptions at the wrist in an experimentally produced Colles fracture
    • Orthopaedic Research Society, Feb 17-20, Washington, DC
    • Berg DC, Lobosky DA: Ligamentous disruptions at the wrist in an experimentally produced Colles fracture. 38th Annual Meeting. Orthopaedic Research Society, Feb 17-20, 1992, Washington, DC.
    • (1992) 38th Annual Meeting
    • Berg, D.C.1    Lobosky, D.A.2
  • 2
    • 0022324518 scopus 로고
    • Comparison of internal fixation techniques in metacarpal fractures
    • Black DM, Mann RJ, Constine R, Daniels AU: Comparison of internal fixation techniques in metacarpal fractures. J Hand Surg 10A:466-472, 1985.
    • (1985) J Hand Surg , vol.10 A , pp. 466-472
    • Black, D.M.1    Mann, R.J.2    Constine, R.3    Daniels, A.U.4
  • 3
    • 0023033322 scopus 로고
    • The stability of internal fixation in the proximal phalanx
    • Black DM, Mann RJ, Constine RM, Daniels AU: The stability of internal fixation in the proximal phalanx. J Hand Surg 11A:672-677, 1986.
    • (1986) J Hand Surg , vol.11 A , pp. 672-677
    • Black, D.M.1    Mann, R.J.2    Constine, R.M.3    Daniels, A.U.4
  • 4
    • 0027360136 scopus 로고
    • Comparative fatigue strengths and stabilities of metacarpal internal fixation techniques
    • Firoozbakhsh K, Moneim MS, Howey T, et al: Comparative fatigue strengths and stabilities of metacarpal internal fixation techniques. J Hand Surg 18A:1059-1068, 1993.
    • (1993) J Hand Surg , vol.18 A , pp. 1059-1068
    • Firoozbakhsh, K.1    Moneim, M.S.2    Howey, T.3
  • 5
    • 0014176114 scopus 로고
    • Fracture of the distal radius including sequelae-shoulder-hand-finger syndrome, disturbance in the distal radio-ulnar joint and impairment of nerve function
    • Frykman G: Fracture of the distal radius including sequelae-shoulder-hand-finger syndrome, disturbance in the distal radio-ulnar joint and impairment of nerve function. Acta Orthop Scand 108(Suppl):1-153, 1967.
    • (1967) Acta Orthop Scand , vol.108 , Issue.SUPPL. , pp. 1-153
    • Frykman, G.1
  • 6
    • 0018350739 scopus 로고
    • The mechanical stability of internal fixation of fractured phalanges
    • Fyfe IS, Mason S: The mechanical stability of internal fixation of fractured phalanges. Hand 11:50-54, 1979.
    • (1979) Hand , vol.11 , pp. 50-54
    • Fyfe, I.S.1    Mason, S.2
  • 7
    • 0022283277 scopus 로고
    • A quantitative comparison of metacarpal fracture stability with five different methods of internal fixation
    • Mann RD, Black D, Constine R, Daniels AU: A quantitative comparison of metacarpal fracture stability with five different methods of internal fixation. J Hand Surg 10A:1042-1128, 1985.
    • (1985) J Hand Surg , vol.10 A , pp. 1042-1128
    • Mann, R.D.1    Black, D.2    Constine, R.3    Daniels, A.U.4
  • 8
    • 0018770428 scopus 로고
    • Comparison of rigidity of whole tubular bones
    • Mason SM, Fyfe IS: Comparison of rigidity of whole tubular bones. J Biomech 12:367-372, 1979.
    • (1979) J Biomech , vol.12 , pp. 367-372
    • Mason, S.M.1    Fyfe, I.S.2
  • 9
    • 0020049442 scopus 로고
    • A phalangeal fracture model quantitative analysis or rigidity and failure
    • Massengill JB, Alexander H, Langrana N, Mylod A: A phalangeal fracture model quantitative analysis or rigidity and failure. J Hand Surg 7:264-279, 1982.
    • (1982) J Hand Surg , vol.7 , pp. 264-279
    • Massengill, J.B.1    Alexander, H.2    Langrana, N.3    Mylod, A.4
  • 10
    • 0017200416 scopus 로고
    • The ligaments of human wrist and their functional significance
    • Mayfield JK, Johnson RP, Kilcoyne RF: The ligaments of human wrist and their functional significance. Anat Rec 186:417-428, 1976.
    • (1976) Anat Rec , vol.186 , pp. 417-428
    • Mayfield, J.K.1    Johnson, R.P.2    Kilcoyne, R.F.3
  • 11
    • 0026317893 scopus 로고
    • Biomechanical and functional testing of plate fixation devices for proximal phalangeal fractures
    • Nunley JA, Kloen P: Biomechanical and functional testing of plate fixation devices for proximal phalangeal fractures. J Hand Surg 16A:991-998, 1991.
    • (1991) J Hand Surg , vol.16 A , pp. 991-998
    • Nunley, J.A.1    Kloen, P.2
  • 13
    • 0021260383 scopus 로고
    • The comparative strengths of internal fixation techniques
    • Vanik RK, Weber RC, Matloub HS, et al: The comparative strengths of internal fixation techniques. J Hand Surg 9A:216-221, 1984.
    • (1984) J Hand Surg , vol.9 A , pp. 216-221
    • Vanik, R.K.1    Weber, R.C.2    Matloub, H.S.3
  • 14
    • 0023932129 scopus 로고
    • Comparative mechanical properties of various Kirschner wire configurations in transverse and oblique phalangeal fractures
    • Viegas SV, Ferren LF, Self J, Tencer AF: Comparative mechanical properties of various Kirschner wire configurations in transverse and oblique phalangeal fractures. J Hand Surg 13A:246-253, 1988.
    • (1988) J Hand Surg , vol.13 A , pp. 246-253
    • Viegas, S.V.1    Ferren, L.F.2    Self, J.3    Tencer, A.F.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.