메뉴 건너뛰기




Volumn , Issue , 2009, Pages

Bio-compatible implantable micro-LC sensor for tissue characterization

Author keywords

[No Author keywords available]

Indexed keywords

CONTINUOUS MONITORING; EXPERIMENTAL TESTING; INPUT ADMITTANCE; LC SENSOR; PHYSIOLOGICAL DATA; TISSUE CHARACTERIZATION; TISSUE MODELS; WORK FOCUS;

EID: 71049180915     PISSN: 15223965     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/APS.2009.5171999     Document Type: Conference Paper
Times cited : (3)

References (7)
  • 1
    • 65549124512 scopus 로고    scopus 로고
    • A Feasibility Study of Tissue Characterization Using LC Sensors
    • Accepted for publication in, Special Issue on Antennas and Propagation for Body-Centric Wireless Communications
    • YvanoffM. and Venkataraman J., "A Feasibility Study of Tissue Characterization Using LC Sensors" Accepted for publication in IEEE Transactions on Antennas and Propagation, Special Issue on Antennas and Propagation for Body-Centric Wireless Communications.
    • IEEE Transactions on Antennas and Propagation
    • YvanoffM1    Venkataraman, J.2
  • 2
    • 0001574753 scopus 로고    scopus 로고
    • Micromachined, polyimide based devices for flexible neural interfaces
    • T. Stieglitz, H. Beutel, M. Schuettler, J.-U. Meyer, "Micromachined, polyimide based devices for flexible neural interfaces," Biomed. Microdev.,vol. 2, no. 4, p. 283, 2000.
    • (2000) Biomed. Microdev , vol.2 , Issue.4 , pp. 283
    • Stieglitz, T.1    Beutel, H.2    Schuettler, M.3    Meyer, J.-U.4
  • 3
    • 34548515094 scopus 로고    scopus 로고
    • Wireless flexible capacitive sensor based on ultra-flexible epoxy resin for strain measurement of automobile tires
    • Ryosuke Matsuzaki, Akira Todoroki, "Wireless flexible capacitive sensor based on ultra-flexible epoxy resin for strain measurement of automobile tires," Sensors and Actuators A: Physical,140-1, 2007, pp.32-42.
    • (2007) Sensors and Actuators A: Physical , vol.140 -1 , pp. 32-42
    • Matsuzaki, R.1    Todoroki, A.2
  • 4
    • 0029909341 scopus 로고    scopus 로고
    • S. Gabriel, R.W. Lau and C. Gabriel The dielectric properties of biological tissues:II.Measurements in the frequency range 10Hz to 20GHz,Phys. Med. BioI.vo1.41, 1996.
    • S. Gabriel, R.W. Lau and C. Gabriel "The dielectric properties of biological tissues:II.Measurements in the frequency range 10Hz to 20GHz,"Phys. Med. BioI.vo1.41, 1996.
  • 7
    • 0029735372 scopus 로고    scopus 로고
    • Analysis of dielectric sensors for the cure monitoring of resin matrix composite materials
    • J.S Kim, D.G. Lee," Analysis of dielectric sensors for the cure monitoring of resin matrix composite materials," Sensors and Actuators B,vol. 30, 1996, pp. 159-164.
    • (1996) Sensors and Actuators B , vol.30 , pp. 159-164
    • Kim, J.S.1    Lee, D.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.