메뉴 건너뛰기




Volumn 11, Issue 11, 2009, Pages 1501-1504

Extraction of pacemaker and implantable cardioverter defibrillator leads: A single-centre study of electrosurgical and laser extraction

Author keywords

Diathermy; Electrophysiology; Implantable cardioverter defibrillator; Laser; Lead extraction; Pacemaker

Indexed keywords

ADULT; ARTICLE; ARTIFICIAL HEART PACEMAKER; CARDIOVERSION; DEFIBRILLATION; DEFIBRILLATOR; DEVICE REMOVAL; DIATHERMY; ELECTROSURGERY; EXCIMER LASER; FEMALE; FLUOROSCOPY; HEART TAMPONADE; HUMAN; IMPLANTATION; INFECTION; MAJOR CLINICAL STUDY; MALE; PACEMAKER ELECTRODE; PACEMAKER LEAD EXTRACTION; PERICARDIAL EFFUSION; PRIORITY JOURNAL; RADIOFREQUENCY; RETROSPECTIVE STUDY; TREATMENT FAILURE; TREATMENT OUTCOME;

EID: 71049177346     PISSN: 10995129     EISSN: 15322092     Source Type: Journal    
DOI: 10.1093/europace/eup263     Document Type: Article
Times cited : (24)

References (11)
  • 2
    • 58149086015 scopus 로고    scopus 로고
    • Performance and survival of transvenous defibrillation leads: Need for a European data registry
    • Goette A, Cantu F, van Erven L, Geelen P, Halimi F, Merino JL et al. Performance and survival of transvenous defibrillation leads: Need for a European data registry. Europace 2009;11:31-34
    • (2009) Europace , vol.11 , pp. 31-34
    • Goette, A.1    Cantu, F.2    Van Erven, L.3    Geelen, P.4    Halimi, F.5    Merino, J.L.6
  • 3
    • 33846928759 scopus 로고    scopus 로고
    • Pacemaker and ICD lead extraction with electrosurgical dissection sheaths and standard transvenous extraction systems: Results of a randomized trial
    • Neuzil P, Taborsky M, Rezek Z, Vopalka R, Sediva L, Niederle P et al. Pacemaker and ICD lead extraction with electrosurgical dissection sheaths and standard transvenous extraction systems: Results of a randomized trial. Europace 2007;9: 98-104.
    • (2007) Europace , vol.9 , pp. 98-104
    • Neuzil, P.1    Taborsky, M.2    Rezek, Z.3    Vopalka, R.4    Sediva, L.5    Niederle, P.6
  • 4
    • 0036311856 scopus 로고    scopus 로고
    • Pacemaker lead extraction with the needle's eye snare for countertraction via a femoral approach
    • Klug D, Jarwe M, Messaoudene SA, Kouakam C, Marquie C, Gay A et al. Pacemaker lead extraction with the needle's eye snare for countertraction via a femoral approach. Pacing Clin Electrophysiol 2002;25:1023-1028
    • (2002) Pacing Clin Electrophysiol , vol.25 , pp. 1023-1028
    • Klug, D.1    Jarwe, M.2    Messaoudene, S.A.3    Kouakam, C.4    Marquie, C.5    Gay, A.6
  • 5
    • 0033133418 scopus 로고    scopus 로고
    • Pacemaker lead extraction with the laser sheath: Results of the pacing lead extraction with the excimer sheath (PLEXES) trial
    • Wilkoff BL, Byrd CL, Love CJ, Hayes DL, Sellers TD, Schaerf R et al. Pacemaker lead extraction with the laser sheath: Results of the pacing lead extraction with the excimer sheath (PLEXES) trial. J Am Coll Cardiol 1999;33:1671-1676
    • (1999) J Am Coll Cardiol , vol.33 , pp. 1671-1676
    • Wilkoff, B.L.1    Byrd, C.L.2    Love, C.J.3    Hayes, D.L.4    Sellers, T.D.5    Schaerf, R.6
  • 6
    • 0035003228 scopus 로고    scopus 로고
    • Excimer laser for pacemaker and defibrillator lead extraction: Techniques and clinical results
    • Gilligan DM, Dan D. Excimer laser for pacemaker and defibrillator lead extraction: Techniques and clinical results. Lasers Med Sci 2001;16:113-121
    • (2001) Lasers Med Sci , vol.16 , pp. 113-121
    • Gilligan, D.M.1    Dan, D.2
  • 7
    • 11144323306 scopus 로고    scopus 로고
    • Intravascular pacemaker and defibrillator lead extraction: A state-of-the-art review
    • Verma A, Wilkoff BL. Intravascular pacemaker and defibrillator lead extraction: A state-of-the-art review. Heart Rhythm 2004;1:739-745
    • (2004) Heart Rhythm , vol.1 , pp. 739-745
    • Verma, A.1    Wilkoff, B.L.2
  • 8
    • 40849114529 scopus 로고    scopus 로고
    • Large, single-center, singleoperator experience with transvenous lead extraction: Outcomes and changing indications
    • Jones SO IV, Eckart RE, Albert CM, Epstein LM. Large, single-center, singleoperator experience with transvenous lead extraction: outcomes and changing indications. Heart Rhythm 2008;5:520-525
    • (2008) Heart Rhythm , vol.5 , pp. 520-525
    • Jones So, I.V.1    Eckart, R.E.2    Albert, C.M.3    Epstein, L.M.4
  • 9
    • 0032873111 scopus 로고    scopus 로고
    • Intravascular extraction of problematic or infected permanent pacemaker leads: 1994-1996
    • U.S. Extraction Database, MED Institute
    • Byrd CL, Wilkoff BL, Love CJ, Sellers TD, Turk KT, Reeves R et al. Intravascular extraction of problematic or infected permanent pacemaker leads: 1994-1996. U.S. Extraction Database, MED Institute. Pacing Clin Electrophysiol 1999;22: 1348-1357
    • (1999) Pacing Clin Electrophysiol , vol.22 , pp. 1348-1357
    • Byrd, C.L.1    Wilkoff, B.L.2    Love, C.J.3    Sellers, T.D.4    Turk, K.T.5    Reeves, R.6
  • 10
    • 44349179244 scopus 로고    scopus 로고
    • Extraction of transvenous pacing and ICD leads
    • Smith MC, Love CJ. Extraction of transvenous pacing and ICD leads. Pacing Clin Electrophysiol 2008;31:736-752
    • (2008) Pacing Clin Electrophysiol , vol.31 , pp. 736-752
    • Smith, M.C.1    Love, C.J.2
  • 11
    • 0031755323 scopus 로고    scopus 로고
    • Learning curve characteristics of pacing lead extraction with a laser sheath
    • Bracke FA, Meijer A, Van Gelder B. Learning curve characteristics of pacing lead extraction with a laser sheath. Pacing Clin Electrophysiol 1998;21:2309-2313
    • (1998) Pacing Clin Electrophysiol , vol.21 , pp. 2309-2313
    • Bracke, F.A.1    Meijer, A.2    Van Gelder, B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.