메뉴 건너뛰기




Volumn 28, Issue 1, 2010, Pages 70-76

Dependence of the fractional anisotropy in cervical spine from the number of diffusion gradients, repeated acquisition and voxel size

Author keywords

Diffusion; DTI; Fractional anisotropy; Spinal cord

Indexed keywords

ADULT; ANALYTICAL PARAMETERS; ANISOTROPY; ARTICLE; CERVICAL SPINAL CORD; CONTROLLED STUDY; DIFFUSION GRADIENT DIRECTION NUMBER; DIFFUSION TENSOR IMAGING; FEMALE; HUMAN; HUMAN EXPERIMENT; IMAGE ANALYSIS; IMAGE DISPLAY; IMAGE ENHANCEMENT; IMAGE PROCESSING; IMAGE QUALITY; MALE; MEASUREMENT ERROR; NEUROIMAGING; NORMAL HUMAN; PRIORITY JOURNAL; QUANTITATIVE ANALYSIS; REPEAT PROCEDURE; SIGNAL NOISE RATIO; SYSTEMATIC ERROR; VOXEL SIZE;

EID: 71049175835     PISSN: 0730725X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.mri.2009.05.046     Document Type: Article
Times cited : (40)

References (21)
  • 1
    • 0036868692 scopus 로고    scopus 로고
    • The basis of anisotropic water diffusion in the nervous system - a technical review
    • Beaulieu C. The basis of anisotropic water diffusion in the nervous system - a technical review. NMR Biomed 15 (2002) 435-455
    • (2002) NMR Biomed , vol.15 , pp. 435-455
    • Beaulieu, C.1
  • 3
    • 0033007902 scopus 로고    scopus 로고
    • Three-dimensional tracking of axonal projections in the brain by magnetic resonance imaging
    • Mori S., Crain B.J., Chacko V.P., and Van Zijl P.C.M. Three-dimensional tracking of axonal projections in the brain by magnetic resonance imaging. Ann Neurol 45 (1999) 265-269
    • (1999) Ann Neurol , vol.45 , pp. 265-269
    • Mori, S.1    Crain, B.J.2    Chacko, V.P.3    Van Zijl, P.C.M.4
  • 4
    • 2942532432 scopus 로고    scopus 로고
    • Characterization of central nervous system structure by magnetic resonance diffusion anisotropy
    • Mamata H., Jolesz F.A., and Maier S.E. Characterization of central nervous system structure by magnetic resonance diffusion anisotropy. Neurochem Int 45 (2004) 553-560
    • (2004) Neurochem Int , vol.45 , pp. 553-560
    • Mamata, H.1    Jolesz, F.A.2    Maier, S.E.3
  • 5
    • 34347240742 scopus 로고    scopus 로고
    • Effects of diffusion weighting schemes on the reproducibility of DTI-derived fractional anisotropy, mean diffusivity, and principal eigenvector measurements at 1.5T
    • Landman B.A., Farrell J.A.D., Jones C.K., Smith S.A., Prince J.L., and Mori S. Effects of diffusion weighting schemes on the reproducibility of DTI-derived fractional anisotropy, mean diffusivity, and principal eigenvector measurements at 1.5T. Neuroimage 36 (2007) 1123-1138
    • (2007) Neuroimage , vol.36 , pp. 1123-1138
    • Landman, B.A.1    Farrell, J.A.D.2    Jones, C.K.3    Smith, S.A.4    Prince, J.L.5    Mori, S.6
  • 6
    • 33748797720 scopus 로고    scopus 로고
    • Effects of number of diffusion gradient directions on derived diffusion tensor imaging indices in human brain
    • Ni H., Kavcic V., Zhu T., Ekholm S., and Zhong J. Effects of number of diffusion gradient directions on derived diffusion tensor imaging indices in human brain. AJNR Am J Neuroradiol 27 (2006) 1776-1781
    • (2006) AJNR Am J Neuroradiol , vol.27 , pp. 1776-1781
    • Ni, H.1    Kavcic, V.2    Zhu, T.3    Ekholm, S.4    Zhong, J.5
  • 7
    • 20644442872 scopus 로고    scopus 로고
    • Mean diffusivity and fractional anisotropy histogram analysis of the cervical cord in MS patients
    • Valsasina P., Rocca M.A., Agosta F., Benedetti B., Horsfield M.A., Gallo A., et al. Mean diffusivity and fractional anisotropy histogram analysis of the cervical cord in MS patients. Neuroimage 26 (2005) 822-828
    • (2005) Neuroimage , vol.26 , pp. 822-828
    • Valsasina, P.1    Rocca, M.A.2    Agosta, F.3    Benedetti, B.4    Horsfield, M.A.5    Gallo, A.6
  • 8
  • 10
    • 21244469101 scopus 로고    scopus 로고
    • Apparent diffusion coefficient and fractional anisotropy in spinal cord: age and cervical spondylosis-related changes
    • Mamata H., Jolesz F.A., and Maier S.E. Apparent diffusion coefficient and fractional anisotropy in spinal cord: age and cervical spondylosis-related changes. J Magn Reson Imaging 22 (2005) 38-43
    • (2005) J Magn Reson Imaging , vol.22 , pp. 38-43
    • Mamata, H.1    Jolesz, F.A.2    Maier, S.E.3
  • 11
    • 34848853605 scopus 로고    scopus 로고
    • Diffusion tensor MR imaging of the cervical spinal cord in patients with multiple sclerosis
    • Ohgiya Y., Oka M., Hiwatashi A., Liu X., Kakimoto N., Westesson P.L.A., et al. Diffusion tensor MR imaging of the cervical spinal cord in patients with multiple sclerosis. Eur Radiol 17 (2007) 2499-2504
    • (2007) Eur Radiol , vol.17 , pp. 2499-2504
    • Ohgiya, Y.1    Oka, M.2    Hiwatashi, A.3    Liu, X.4    Kakimoto, N.5    Westesson, P.L.A.6
  • 12
    • 33747405927 scopus 로고    scopus 로고
    • Diffusion tensor imaging in multiple sclerosis: assessment of regional differences in the axial plane within normal-appearing cervical spinal cord
    • Hesseltine S.M., Law M., Babb J., Rad M., Lopez S., Ge Y., et al. Diffusion tensor imaging in multiple sclerosis: assessment of regional differences in the axial plane within normal-appearing cervical spinal cord. AJNR Am J Neuroradiol 27 (2006) 1189-1193
    • (2006) AJNR Am J Neuroradiol , vol.27 , pp. 1189-1193
    • Hesseltine, S.M.1    Law, M.2    Babb, J.3    Rad, M.4    Lopez, S.5    Ge, Y.6
  • 13
    • 34250013841 scopus 로고    scopus 로고
    • Understanding diffusion MR imaging techniques: from scalar diffusion-weighted imaging to diffusion tensor imaging and beyond
    • Hagmann P., Jonasson L., Maeder P., Thiran J.P., Wedeen V.J., and Meuli R. Understanding diffusion MR imaging techniques: from scalar diffusion-weighted imaging to diffusion tensor imaging and beyond. Radiographics 26 (2006) S205-S223
    • (2006) Radiographics , vol.26
    • Hagmann, P.1    Jonasson, L.2    Maeder, P.3    Thiran, J.P.4    Wedeen, V.J.5    Meuli, R.6
  • 14
  • 15
    • 7544247899 scopus 로고    scopus 로고
    • "Squashing peanuts and smashing pumpkins": how noise distorts diffusion-weighted MR data
    • Jones D.K., and Basser P.J. "Squashing peanuts and smashing pumpkins": how noise distorts diffusion-weighted MR data. Magn Reson Med 52 (2004) 979-993
    • (2004) Magn Reson Med , vol.52 , pp. 979-993
    • Jones, D.K.1    Basser, P.J.2
  • 16
    • 0033945138 scopus 로고    scopus 로고
    • Statistical artifacts in diffusion tensor MRI (DT-MRI) caused by background noise
    • Basser P.J., and Pajevic S. Statistical artifacts in diffusion tensor MRI (DT-MRI) caused by background noise. Magn Reson Med 44 (2000) 41-50
    • (2000) Magn Reson Med , vol.44 , pp. 41-50
    • Basser, P.J.1    Pajevic, S.2
  • 17
    • 37349020933 scopus 로고    scopus 로고
    • An empirical characterization of the quality of DTI data and the efficacy of dyadic sorting
    • Yanasak N.E., Allison J.D., and Hu T.C.C. An empirical characterization of the quality of DTI data and the efficacy of dyadic sorting. Magn Reson Imaging 26 (2008) 122-132
    • (2008) Magn Reson Imaging , vol.26 , pp. 122-132
    • Yanasak, N.E.1    Allison, J.D.2    Hu, T.C.C.3
  • 18
    • 34250850723 scopus 로고    scopus 로고
    • Diffusion anisotropy measurement of brain white matter is affected by voxel size: underestimation occurs in areas with crossing fibers
    • Oouchi H., Yamada K., Sakai K., Kizu O., Kubota T., Ito H., et al. Diffusion anisotropy measurement of brain white matter is affected by voxel size: underestimation occurs in areas with crossing fibers. AJNR Am J Neuroradiol 28 (2007) 1102-1106
    • (2007) AJNR Am J Neuroradiol , vol.28 , pp. 1102-1106
    • Oouchi, H.1    Yamada, K.2    Sakai, K.3    Kizu, O.4    Kubota, T.5    Ito, H.6
  • 19
    • 33747852591 scopus 로고    scopus 로고
    • Optimization of acquisition parameters of diffusion-tensor magnetic resonance imaging in the spinal cord
    • Lee J.W., Kim J.H., Kang H.S., Lee J.S., Choi J.Y., Yeom J.S., et al. Optimization of acquisition parameters of diffusion-tensor magnetic resonance imaging in the spinal cord. Invest Radiol 41 (2006) 553-559
    • (2006) Invest Radiol , vol.41 , pp. 553-559
    • Lee, J.W.1    Kim, J.H.2    Kang, H.S.3    Lee, J.S.4    Choi, J.Y.5    Yeom, J.S.6
  • 20
    • 34547814953 scopus 로고    scopus 로고
    • How does distortion correction correlate with anisotropic indices? A diffusion tensor imaging study
    • Kim D.J., Park H.J., Kang K.W., Shin Y.W., Kim J.J., Moon W.J., et al. How does distortion correction correlate with anisotropic indices? A diffusion tensor imaging study. Magn Reson Imaging 24 (2006) 1369-1376
    • (2006) Magn Reson Imaging , vol.24 , pp. 1369-1376
    • Kim, D.J.1    Park, H.J.2    Kang, K.W.3    Shin, Y.W.4    Kim, J.J.5    Moon, W.J.6
  • 21
    • 33749650160 scopus 로고    scopus 로고
    • A preliminary study of the effects of trigger timing on diffusion tensor imaging of the human spinal cord
    • Summers P., Staempfli, Jaermann T., Kwiecinski S., and Kollias S. A preliminary study of the effects of trigger timing on diffusion tensor imaging of the human spinal cord. AJNR Am J Neuroradiol 27 (2006) 1952-1961
    • (2006) AJNR Am J Neuroradiol , vol.27 , pp. 1952-1961
    • Summers, P.1    Staempfli2    Jaermann, T.3    Kwiecinski, S.4    Kollias, S.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.