메뉴 건너뛰기




Volumn 81, Issue 2, 2006, Pages 106-116

DtiStudio: Resource program for diffusion tensor computation and fiber bundle tracking

Author keywords

Diffusion tensor imaging; Fiber tractography; Magnetic resonance imaging (MRI); Medical image visualization

Indexed keywords

ALGORITHMS; COMPUTATIONAL METHODS; COMPUTER SOFTWARE; DATA STORAGE EQUIPMENT; MAGNETIC RESONANCE IMAGING; MEDICAL IMAGING; RESOURCE ALLOCATION;

EID: 31344441424     PISSN: 01692607     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.cmpb.2005.08.004     Document Type: Article
Times cited : (909)

References (23)
  • 1
    • 0028398052 scopus 로고
    • Estimation of the effective self-diffusion tensor from the NMR spin echo
    • P.J. Basser, J. Mattiello, and D. LeBihan Estimation of the effective self-diffusion tensor from the NMR spin echo J. Magn. Reson. B 103 1994 247 254
    • (1994) J. Magn. Reson. B , vol.103 , pp. 247-254
    • Basser, P.J.1    Mattiello, J.2    LeBihan, D.3
  • 2
    • 0033007902 scopus 로고    scopus 로고
    • Three-dimensional tracking of axonal projections in the brain by magnetic resonance imaging
    • S. Mori, B.J. Crain, V.P. Chacko, and P.C.M. van Zijl Three-dimensional tracking of axonal projections in the brain by magnetic resonance imaging Ann. Neurol. 45 2 1999 265 269
    • (1999) Ann. Neurol. , vol.45 , Issue.2 , pp. 265-269
    • Mori, S.1    Crain, B.J.2    Chacko, V.P.3    Van Zijl, P.C.M.4
  • 3
    • 0032749661 scopus 로고    scopus 로고
    • In vivo three-dimensional reconstruction of rat brain axonal projections by diffusion tensor imaging
    • R. Xue, P.C.M. van Zijl, B.J. Crain, M. Solaiyappan, and S. Mori In vivo three-dimensional reconstruction of rat brain axonal projections by diffusion tensor imaging Magn. Reson. Med. 42 6 1999 1123 1127
    • (1999) Magn. Reson. Med. , vol.42 , Issue.6 , pp. 1123-1127
    • Xue, R.1    Van Zijl, P.C.M.2    Crain, B.J.3    Solaiyappan, M.4    Mori, S.5
  • 5
    • 0032783211 scopus 로고    scopus 로고
    • Non-invasive assessment of axonal fiber connectivity in the human brain via diffusion tensor MRI
    • D.K. Jones, A. Simmons, S.C.R. Williams, and M.A. Horsfield Non-invasive assessment of axonal fiber connectivity in the human brain via diffusion tensor MRI Magn. Reson. Med. 42 1 1999 37 41
    • (1999) Magn. Reson. Med. , vol.42 , Issue.1 , pp. 37-41
    • Jones, D.K.1    Simmons, A.2    Williams, S.C.R.3    Horsfield, M.A.4
  • 8
    • 0033889352 scopus 로고    scopus 로고
    • Regularization of diffusion-based direction maps for the tracking of brain white matter fascicles
    • C. Poupon, C.A. Clark, V. Frouin, J. Regis, I. Bloch, D. Le Bihan, and J.-F. Mangin Regularization of diffusion-based direction maps for the tracking of brain white matter fascicles NeuroImage 12 2 2000 184 195
    • (2000) NeuroImage , vol.12 , Issue.2 , pp. 184-195
    • Poupon, C.1    Clark, C.A.2    Frouin, V.3    Regis, J.4    Bloch, I.5    Le Bihan, D.6    Mangin, J.-F.7
  • 11
    • 0028324684 scopus 로고
    • Correction of motional artifacts in diffusion-weighted NMR images using navigator echoes
    • R.J. Ordidge, J.A. Helpern, Z.X. Qing, R.A. Knight, and V. Nagesh Correction of motional artifacts in diffusion-weighted NMR images using navigator echoes Magn. Reson. Imag. 12 1994 455 460
    • (1994) Magn. Reson. Imag. , vol.12 , pp. 455-460
    • Ordidge, R.J.1    Helpern, J.A.2    Qing, Z.X.3    Knight, R.A.4    Nagesh, V.5
  • 12
    • 0029866438 scopus 로고    scopus 로고
    • Diffusion-weighted interleaved echo-planar imaging with a pair of orthogonal navigator echoes
    • K. Butts, A. de Crespigny, J.M. Pauly, and M. Moseley Diffusion-weighted interleaved echo-planar imaging with a pair of orthogonal navigator echoes Magn. Reson. Med. 35 1996 763 770
    • (1996) Magn. Reson. Med. , vol.35 , pp. 763-770
    • Butts, K.1    De Crespigny, A.2    Pauly, J.M.3    Moseley, M.4
  • 13
    • 0035081921 scopus 로고    scopus 로고
    • Implications of bulk motion for diffusion-weighted imaging experiments: Effects, mechanisms, and solutions
    • D.G. Norris Implications of bulk motion for diffusion-weighted imaging experiments: effects, mechanisms, and solutions J. Magn. Reson. Imag. 13 2001 486 495
    • (2001) J. Magn. Reson. Imag. , vol.13 , pp. 486-495
    • Norris, D.G.1
  • 14
    • 0036204326 scopus 로고    scopus 로고
    • Origin and minimization of residual motion-related artifacts in navigator-corrected segmented diffusion-weighted EPI of the human brain
    • H. Jiang, X. Golay, P.C.M. van Zijl, and S. Mori Origin and minimization of residual motion-related artifacts in navigator-corrected segmented diffusion-weighted EPI of the human brain Magn. Reson. Med. 47 4 2002 818 822
    • (2002) Magn. Reson. Med. , vol.47 , Issue.4 , pp. 818-822
    • Jiang, H.1    Golay, X.2    Van Zijl, P.C.M.3    Mori, S.4
  • 15
    • 33646376290 scopus 로고
    • Spin diffusion measurements: Spin echoes in the presence of a time-dependent field gradient
    • E.O. Stejskal, and J.E. Tanner Spin diffusion measurements: spin echoes in the presence of a time-dependent field gradient J. Chem. Phys. 42 1965 184 195
    • (1965) J. Chem. Phys. , vol.42 , pp. 184-195
    • Stejskal, E.O.1    Tanner, J.E.2
  • 16
    • 0028154030 scopus 로고
    • MR diffusion tensor spectroscopy and imaging
    • P.J. Basser, J. Mattiello, and D. LeBihan MR diffusion tensor spectroscopy and imaging Biophys. J. 66 1 1994 259 267
    • (1994) Biophys. J. , vol.66 , Issue.1 , pp. 259-267
    • Basser, P.J.1    Mattiello, J.2    LeBihan, D.3
  • 17
    • 0032835247 scopus 로고    scopus 로고
    • Optimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imaging
    • D.K. Jones, M.A. Horsfield, and A. Simmons Optimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imaging Magn. Reson. Med. 42 3 1999 515 525
    • (1999) Magn. Reson. Med. , vol.42 , Issue.3 , pp. 515-525
    • Jones, D.K.1    Horsfield, M.A.2    Simmons, A.3
  • 18
    • 0034567198 scopus 로고    scopus 로고
    • Condition number as a measure of noise performance of diffusion tensor data acquisision schemes with MRI
    • S. Skare, M. Hedehus, M.E. Moseley, and T.-Q. Li Condition number as a measure of noise performance of diffusion tensor data acquisision schemes with MRI NeuroImage 147 2000 340 352
    • (2000) NeuroImage , vol.147 , pp. 340-352
    • Skare, S.1    Hedehus, M.2    Moseley, M.E.3    Li, T.-Q.4
  • 20
    • 0029908076 scopus 로고    scopus 로고
    • Toward a quantitative assessment of diffusion anisotropy
    • C. Pierpaoli, and P.J. Basser Toward a quantitative assessment of diffusion anisotropy Magn. Reson. Med. 36 1996 893 906
    • (1996) Magn. Reson. Med. , vol.36 , pp. 893-906
    • Pierpaoli, C.1    Basser, P.J.2
  • 21
    • 0035007493 scopus 로고    scopus 로고
    • Anisotropy in high angular resolution diffusion-weighted MRI
    • L.R. Frank Anisotropy in high angular resolution diffusion-weighted MRI Magn. Reson. Med. 45 2001 935 939
    • (2001) Magn. Reson. Med. , vol.45 , pp. 935-939
    • Frank, L.R.1
  • 23
    • 0036741223 scopus 로고    scopus 로고
    • Virtual in vivo interactive dissection of white matter fasciculi in the human brain
    • M. Catani, R.J. Howard, S. Pajevic, and D.K. Jones Virtual in vivo interactive dissection of white matter fasciculi in the human brain NeuroImage 17 2002 77 94
    • (2002) NeuroImage , vol.17 , pp. 77-94
    • Catani, M.1    Howard, R.J.2    Pajevic, S.3    Jones, D.K.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.