메뉴 건너뛰기




Volumn 32, Issue 3, 2009, Pages 129-135

Effects of collimator backscatter in an Elekta linac by Monte Carlo simulation

Author keywords

Linear accelerator; Monte Carlo dose calculation; Radiation therapy; Scatter

Indexed keywords

BACK-SCATTERED; BACKSCATTERED PARTICLES; BACKSCATTERED RADIATION; CORRECTION FACTORS; ENERGY CHARACTERISTICS; FIELD SIZE; FLUENCES; MONTE CARLO DOSE CALCULATION; MONTE CARLO SIMULATION; PHASE-SPACE DATA; PHOTON BEAMS; RADIATION THERAPY; SIZE-DEPENDENCE;

EID: 71049116487     PISSN: 01589938     EISSN: None     Source Type: Journal    
DOI: 10.1007/BF03178640     Document Type: Article
Times cited : (11)

References (15)
  • 1
    • 0242521407 scopus 로고    scopus 로고
    • Monte Carlo modelling of external radiotherapy photon beams
    • DOI 10.1088/0031-9155/48/21/R01, PII S0031915503332245
    • Verhaegen, F. and Seuntjens, J., Monte Carlo modelling of external radiotherapy photon beams, Phys. Med. Biol. 48:R107-R164, 2003. (Pubitemid 37427947)
    • (2003) Physics in Medicine and Biology , vol.48 , Issue.21
    • Verhaegen, F.1    Seuntjens, J.2
  • 2
    • 0035667304 scopus 로고    scopus 로고
    • Measurement of backscattered radiation from secondary collimator jaws into the beam monitor chamber from a dual energy linear accelerator
    • Ravikumar, M. and Ravichandran, R., Measurement of backscattered radiation from secondary collimator jaws into the beam monitor chamber from a dual energy linear accelerator, Strahlentherapie und Onkologie 12:670-675, 2001. (Pubitemid 34015344)
    • (2001) Strahlentherapie und Onkologie , vol.177 , Issue.12 , pp. 670-675
    • Ravikumar, M.1    Ravichandran, R.2
  • 3
    • 0031912342 scopus 로고    scopus 로고
    • Monitor chamber backscatter for intensity modulated radiation therapy using multileaf collimators
    • Hounsell, A. R., Monitor chamber backscatter for intensity modulated radiation therapy using multileaf collimators, Phys. Med. Biol. 43:445-454, 1998.
    • (1998) Phys. Med. Biol. , vol.43 , pp. 445-454
    • Hounsell, A.R.1
  • 4
    • 0034003283 scopus 로고    scopus 로고
    • Modeling photon output caused by backscattered radiation into the monitor chamber from collimator jaws using a Monte Carlo technique
    • Liu, H. H., Mackie, T. R. and McCullough, E. C., Modeling photon output caused by backscattered radiation into the monitor chamber from collimator jaws using a Monte Carlo technique, Med. Phys. 27(4):737-744, 2000.
    • (2000) Med. Phys. , vol.27 , Issue.4 , pp. 737-744
    • Liu, H.H.1    Mackie, T.R.2    McCullough, E.C.3
  • 5
    • 0023221279 scopus 로고
    • The effect of collimator backscatter radiation on photon output of linear accelerators
    • Huang, P. H., Chu, J. and Bjarngard, B. E., The effect of collimator backscatter radiation on photon output of linear accelerators, Med. Phys. 14(2):268-269, 1987.
    • (1987) Med. Phys. , vol.14 , Issue.2 , pp. 268-269
    • Huang, P.H.1    Chu, J.2    Bjarngard, B.E.3
  • 6
    • 14544282452 scopus 로고    scopus 로고
    • Comparison of build-up dose between Elekta and Varian linear accelerators for high-energy photon beams using radiochromic film and clinical implications for IMRT head and neck treatments
    • DOI 10.1088/0031-9155/50/3/002
    • Paelinck, L., de Wagter, C., van Esch, A., Duthoy, W., Depuydt, T. and de Neve, W., Comparison of build-up dose between Elekta and Varian linear accelerators for high-energy photon beams using radiochromic film and clinical implications for IMRT head and neck treatments, Phys. Med. Biol. 50:413-428, 2005. (Pubitemid 40297916)
    • (2005) Physics in Medicine and Biology , vol.50 , Issue.3 , pp. 413-428
    • Paelinck, L.1    De Wagter, C.2    Van Esch, A.3    Duthoy, W.4    Depuydt, T.5    De Neve, W.6
  • 7
    • 34247489391 scopus 로고    scopus 로고
    • Ecliptic method for the determination of backscatter into the beam monitor chambers in photon beams of medical accelerators
    • Sanz, D. E., Alvarez, G. D. and Nelli, F. E., Ecliptic method for the determination of backscatter into the beam monitor chambers in photon beams of medical accelerators, Phys. Med. Biol. 52:1647-1658, 2007.
    • (2007) Phys. Med. Biol. , vol.52 , pp. 1647-1658
    • Sanz, D.E.1    Alvarez, G.D.2    Nelli, F.E.3
  • 8
    • 4644253384 scopus 로고    scopus 로고
    • Output ratio in air for MLC shaped irregular fields
    • Zhu, T. C., Bjarngard, B. E., Xiao, Y. and Bieda, M., Output ratio in air for MLC shaped irregular fields, Med. Phys. 31(9):2480-2490, 2004.
    • (2004) Med. Phys. , vol.31 , Issue.9 , pp. 2480-2490
    • Zhu, T.C.1    Bjarngard, B.E.2    Xiao, Y.3    Bieda, M.4
  • 9
    • 0033781491 scopus 로고    scopus 로고
    • Backscatter towards the monitor ion chamber in high-energy photon and electron beams: Charge integration versus Monte Carlo simulation
    • DOI 10.1088/0031-9155/45/11/304, PII S0031915500132348
    • Verhaegen, F., Symonds-Tayler, R., Liu, H. H. and Nahum, A. E., Backscatter towards the monitor ion chamber in high-energy photon and electron beams: charge integration versus Monte Carlo simulation, Phys. Med. Biol. 45:3159-3170, 2000. (Pubitemid 30836580)
    • (2000) Physics in Medicine and Biology , vol.45 , Issue.11 , pp. 3159-3170
    • Verhaegen, F.1    Symonds-Tayler, R.2    Liu, H.H.3    Nahum, A.E.4
  • 10
    • 0029035150 scopus 로고
    • BEAM: A Monte Carlo code to simulate radiotherapy treatment units
    • Rogers, D. W. O., Faddegon, B. A., Ding, G. X., Ma, C. M., We, J. and Mackie, T. R., BEAM: A Monte Carlo code to simulate radiotherapy treatment units, Med. Phys. 22(5):503-524, 1995.
    • (1995) Med. Phys. , vol.22 , Issue.5 , pp. 503-524
    • Rogers, D.W.O.1    Faddegon, B.A.2    Ding, G.X.3    Ma, C.M.4    We, J.5    Mackie, T.R.6
  • 11
    • 0036130665 scopus 로고    scopus 로고
    • Monte Carlo calculation of nine megavoltage photon beam spectra using BEAM code
    • Sheikh-Bagheri, D. and Rogers, D. W. O., Monte Carlo calculation of nine megavoltage photon beam spectra using BEAM code, Med. Phys. 29(3):391-402, 2002.
    • (2002) Med. Phys. , vol.29 , Issue.3 , pp. 391-402
    • Sheikh-Bagheri, D.1    Rogers, D.W.O.2
  • 12
    • 33746608072 scopus 로고    scopus 로고
    • Efficient photon beam dose calculations using DOSXYZnrc with BEAMnrc
    • Kawrakow, I. and Walters, B. R. B., Efficient photon beam dose calculations using DOSXYZnrc with BEAMnrc, Med. Phys. 33(8):3046-3056, 2006.
    • (2006) Med. Phys. , vol.33 , Issue.8 , pp. 3046-3056
    • Kawrakow, I.1    Walters, B.R.B.2
  • 13
    • 0004286738 scopus 로고    scopus 로고
    • Ionising Radiation Standards, National Research Council of Canada, Ottawa
    • Rogers, D. W. O., Walters, B. and Kawrakow, I. BEAMnrc Users Manual, Ionising Radiation Standards, National Research Council of Canada, Ottawa, 2004.
    • (2004) BEAMnrc Users Manual
    • Rogers, D.W.O.1    Walters, B.2    Kawrakow, I.3
  • 14
    • 47649110452 scopus 로고    scopus 로고
    • Radiotherapy treatment verification using radiological thickness measured with an amorphous silicon electronic portal imaging device: Monte Carlo simulation and experiment
    • DOI 10.1088/0031-9155/53/14/012, PII S0031915508698218
    • Kairn, T., Cassidy, D., Sandford, P. M. and Fielding, A. L., Radiotherapy treatment verification using radiological thickness measured with an amorphous silicon electronic portal imaging device: Monte Carlo simulation and experiment, Phys. Med. Biol. 53(14):3903-3919, 2008. (Pubitemid 352020272)
    • (2008) Physics in Medicine and Biology , vol.53 , Issue.14 , pp. 3903-3919
    • Kairn, T.1    Cassidy, D.2    Sandford, P.M.3    Fielding, A.L.4
  • 15
    • 22244482238 scopus 로고    scopus 로고
    • Absolute dose calculations for Monte Carlo simulations of radiotherapy beams
    • DOI 10.1088/0031-9155/50/14/013
    • Popescu, I. A., Shaw, C. P., Zavgorodni, S. F. and Beckham, W. A., Absolute dose calculations for Monte Carlo simulations of radiotherapy beams, Phys. Med. Biol. 50:3375-3392, 2005. (Pubitemid 40991696)
    • (2005) Physics in Medicine and Biology , vol.50 , Issue.14 , pp. 3375-3392
    • Popescu, I.A.1    Shaw, C.P.2    Zavgorodni, S.F.3    Beckham, W.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.