메뉴 건너뛰기




Volumn 52, Issue 6, 2007, Pages 1647-1658

Ecliptic method for the determination of backscatter into the beam monitor chambers in photon beams of medical accelerators

Author keywords

[No Author keywords available]

Indexed keywords

DATA ACQUISITION; DOSIMETERS; LIGHT; LINEAR ACCELERATORS; OPTICAL COLLIMATORS; PHOTONS;

EID: 34247489391     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/52/6/007     Document Type: Article
Times cited : (5)

References (13)
  • 1
    • 0026697038 scopus 로고
    • Application to the convolution method for calculation of output factors for therapy photon beams
    • Ahnesjo A, Knoos T and Montelius A 1992 Application to the convolution method for calculation of output factors for therapy photon beams Med. Phys. 19 295-301
    • (1992) Med. Phys. , vol.19 , Issue.2 , pp. 295-301
    • Ahnesjo, A.1    Knoos, T.2    Montelius, A.3
  • 2
    • 0027230782 scopus 로고
    • Backscatter into the beam monitor chamber: Implications for dosimetry of asymmetric collimators
    • Duzenli C, McClean B and Field C 1993 Backscatter into the beam monitor chamber: implications for dosimetry of asymmetric collimators Med. Phys. 20 363-67
    • (1993) Med. Phys. , vol.20 , Issue.2 , pp. 363-367
    • Duzenli, C.1    McClean, B.2    Field, C.3
  • 3
    • 0031912342 scopus 로고    scopus 로고
    • Monitor chamber backscatter for intensity modulated radiation therapy using multileaf collimators
    • Hounsell A R 1998 Monitor chamber backscatter for intensity modulated radiation therapy using multileaf collimators Phys. Med. Biol. 43 445-54
    • (1998) Phys. Med. Biol. , vol.43 , Issue.2 , pp. 445-454
    • Hounsell, A.R.1
  • 4
    • 0023221279 scopus 로고
    • The effect of collimator backscatter radiation on photon output of linear accelerators
    • Huang P-H, Chu J and Bjärngard B E 1987 The effect of collimator backscatter radiation on photon output of linear accelerators Med. Phys. 14 268-9
    • (1987) Med. Phys. , vol.14 , Issue.2 , pp. 268-269
    • Huang, P.-H.1    Chu, J.2    Bjärngard, B.E.3
  • 5
    • 0024547608 scopus 로고
    • Telescopic measurement of backscattered radiation from secondary collimator jaws to a beam monitor chamber using a pair of slits
    • Kubo H 1989 Telescopic measurement of backscattered radiation from secondary collimator jaws to a beam monitor chamber using a pair of slits Med. Phys. 16 295-8
    • (1989) Med. Phys. , vol.16 , Issue.2 , pp. 295-298
    • Kubo, H.1
  • 6
    • 0031897239 scopus 로고    scopus 로고
    • Measurement of backscatter to the monitor chamber of medical accelerators using target charge
    • Lam K L, Muthuswamy M S and Ten Haken R K 1998 Measurement of backscatter to the monitor chamber of medical accelerators using target charge Med. Phys. 25 334-8
    • (1998) Med. Phys. , vol.25 , Issue.3 , pp. 334-338
    • Lam, K.L.1    Muthuswamy, M.S.2    Ten Haken, R.K.3
  • 7
    • 0034003283 scopus 로고    scopus 로고
    • Modeling photon output caused by backscattered radiation into the monitor chamber from collimator jaws using a Monte Carlo technique
    • Liu H H, Mackie T R and McCullough E C 2000 Modeling photon output caused by backscattered radiation into the monitor chamber from collimator jaws using a Monte Carlo technique Med. Phys. 27 737-44
    • (2000) Med. Phys. , vol.27 , Issue.4 , pp. 737-744
    • Liu, H.H.1    MacKie, T.R.2    McCullough, E.C.3
  • 8
    • 0023905228 scopus 로고
    • Output factor constituents of high energy photon beams
    • Luxton G and Astrahan M A 1988 Output factor constituents of high energy photon beams Med. Phys. 15 88-91
    • (1988) Med. Phys. , vol.15 , Issue.1 , pp. 88-91
    • Luxton, G.1    Astrahan, M.A.2
  • 9
    • 0019461282 scopus 로고
    • Characteristics of an 18 MV photon beam from a Therac 20 Medical Linear Accelerator
    • Patterson M S and Shragge P C 1981 Characteristics of an 18 MV photon beam from a Therac 20 Medical Linear Accelerator Med. Phys. 8 312-8
    • (1981) Med. Phys. , vol.8 , Issue.3 , pp. 312-318
    • Patterson, M.S.1    Shragge, P.C.2
  • 10
    • 0017659329 scopus 로고
    • Backscatter from high atomic number materials in high energy photon beams
    • Scrimger J W 1977 Backscatter from high atomic number materials in high energy photon beams Radiology 124 815-7
    • (1977) Radiology , vol.124 , pp. 815-817
    • Scrimger, J.W.1
  • 11
    • 0033781491 scopus 로고    scopus 로고
    • Backscatter towards the monitor ion chamber in high-energy photon and electron beams: Charge integration versus Monte Carlo simulation
    • Verhaegen F, Symonds-Tayler R, Liu H H and Nahum A E 2000 Backscatter towards the monitor ion chamber in high-energy photon and electron beams: charge integration versus Monte Carlo simulation Phys. Med. Biol. 45 3159-70
    • (2000) Phys. Med. Biol. , vol.45 , Issue.11 , pp. 3159-3170
    • Verhaegen, F.1    Symonds-Tayler, R.2    Liu, H.H.3    Nahum, A.E.4
  • 12
    • 0023513127 scopus 로고
    • Measurement of beam current and evaluation of scatter production in a 18-MeV accelerator
    • Watts D L and Ibbott G S 1987 Measurement of beam current and evaluation of scatter production in a 18-MeV accelerator Med. Phys. 14 662-4
    • (1987) Med. Phys. , vol.14 , Issue.4 , pp. 662-664
    • Watts, D.L.1    Ibbott, G.S.2
  • 13
    • 0029785031 scopus 로고    scopus 로고
    • Measurement of photon beam backscatter from collimators to the beam monitor chambers using target-current-pulse-counting and telescope techniques
    • Yu M K, Sloboda R S and Mansour F 1996 Measurement of photon beam backscatter from collimators to the beam monitor chambers using target-current-pulse-counting and telescope techniques Phys. Med. Biol. 41 1107-17
    • (1996) Phys. Med. Biol. , vol.41 , Issue.7 , pp. 1107-1117
    • Yu, M.K.1    Sloboda, R.S.2    Mansour, F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.