메뉴 건너뛰기




Volumn 11, Issue 6, 2009, Pages 1213-1221

Development of a novel intra-vaginal transducer with improved dynamic response

Author keywords

Dynamic response; Frequency response; Intra abdominal pressure; Physical activity; Pressure sensor; Pressure transducer; Vaginal transducer

Indexed keywords

ACCURATE MEASUREMENT; CLINICAL TESTS; FLUID-FILLED; INTRA-ABDOMINAL PRESSURES; PHYSICAL ACTIVITY; RELIABLE MEASUREMENT; SYMMETRIC DESIGN;

EID: 70549110133     PISSN: 13872176     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10544-009-9339-z     Document Type: Article
Times cited : (11)

References (26)
  • 2
    • 70549103703 scopus 로고    scopus 로고
    • Blood pressure transducers, American National Standard, ANSI/AAMI BP22:1994/(R)2001/(R)2006, Revision/combination of ANSI/AAMI BP22:1986 & ANSI/AAMI BP23:1986 Blood pressure transducers, Developed by Association for the Advancement of Medical Instrumentation, Approved 30 August 1994 by American National Standards Institute, Inc.
    • Blood pressure transducers, American National Standard, ANSI/AAMI BP22:1994/(R)2001/(R)2006, Revision/combination of ANSI/AAMI BP22:1986 & ANSI/AAMI BP23:1986 Blood pressure transducers, Developed by Association for the Advancement of Medical Instrumentation, Approved 30 August 1994 by American National Standards Institute, Inc.
  • 3
    • 0020728667 scopus 로고
    • 10.1016/0090-4295(83)90103-6
    • GA Barbalias 1983 Urol 21 331 10.1016/0090-4295(83)90103-6
    • (1983) Urol , vol.21 , pp. 331
    • Barbalias, G.A.1
  • 8
    • 5044227189 scopus 로고    scopus 로고
    • Comparison of air-coupled balloon esophageal and anorectal manometry catheters with solid-state esophageal manometry and water-perfused anorectal manometry catheters
    • DOI 10.1023/B:DDAS.0000043382.59539.d3
    • JC Fang K Hilden AK Tuteja KA Peterson 2004 Digest Dis Sci 49 1657 10.1023/B:DDAS.0000043382.59539.d3 (Pubitemid 39335552)
    • (2004) Digestive Diseases and Sciences , vol.49 , Issue.10 , pp. 1657-1663
    • Fang, J.C.1    Hilden, K.2    Tuteja, A.K.3    Peterson, K.A.4
  • 13
    • 0023235249 scopus 로고
    • 10.1007/BF03010146
    • P Hunziker 1987 Can J Anaesth 34 409 10.1007/BF03010146
    • (1987) Can J Anaesth , vol.34 , pp. 409
    • Hunziker, P.1
  • 17
    • 1642306412 scopus 로고    scopus 로고
    • Different techniques to measure intra-abdominal pressura (IAP): Time for a critical re-appraisal
    • DOI 10.1007/s00134-003-2107-2
    • M Malbrain 2004 Intens Care Med 30 357 10.1007/s00134-003-2107-2 (Pubitemid 38375608)
    • (2004) Intensive Care Medicine , vol.30 , Issue.3 , pp. 357-371
    • Malbrain, M.L.N.G.1
  • 18
    • 0020427824 scopus 로고
    • Validity of rectal pressure measurements as indication of intra-abdominal pressure changes during urodynamic evaluation
    • DOI 10.1016/0090-4295(82)90326-0
    • TA Mccarthy 1982 Urol 20 657 10.1016/0090-4295(82)90326-0 (Pubitemid 13221240)
    • (1982) Urology , vol.20 , Issue.6 , pp. 657-660
    • McCarthy, T.A.1
  • 23
    • 43149125435 scopus 로고    scopus 로고
    • Intracranial pressure monitoring
    • DOI 10.1017/S0265021508003517, PII S0265021508003517
    • R Stefini FA Rasulo 2008 Eur J Anaesth 25 192 10.1017/S0265021508003517 (Pubitemid 351643075)
    • (2008) European Journal of Anaesthesiology , vol.25 , Issue.SUPPL. 42 , pp. 192-195
    • Stefini, R.1    Rasulo, F.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.