메뉴 건너뛰기




Volumn , Issue , 2009, Pages 139-144

Alignment correction during metal artifact reduction for CBCT using mutual information and edge filtering

Author keywords

[No Author keywords available]

Indexed keywords

2D PROJECTIONS; A-DENSITY; C-ARM SYSTEMS; CLINICAL IMAGES; COMPUTED TOMOGRAPHY; CONE-BEAM COMPUTED TOMOGRAPHY; EDGE FILTERING; EDGE FILTERS; HIGH-DENSITY; METAL ARTIFACT REDUCTION; METAL PARTS; MUTUAL INFORMATIONS; NOVEL METHODS; PRE-PROCESSING STEP; PROJECTION GEOMETRY; RECONSTRUCTED IMAGE; X-RAY ATTENUATION COEFFICIENT;

EID: 70450265343     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (3)

References (11)
  • 1
    • 33746633331 scopus 로고    scopus 로고
    • Metal artifact reduction in ct using tissue-class modeling and adaptive prefiltering
    • M. Bal and L. Spies, "Metal artifact reduction in ct using tissue-class modeling and adaptive prefiltering", Medical Physics, 33(8), 2006, pp. 2852-2859.
    • (2006) Medical Physics , vol.33 , Issue.8 , pp. 2852-2859
    • Bal, M.1    Spies, L.2
  • 4
    • 0023224718 scopus 로고
    • Reduction of ct artifacts caused by metallic implants
    • Aug
    • W. Kalender, R. Hebele, and J. Ebersberger, "Reduction of ct artifacts caused by metallic implants", Radiology, 164(2), Aug 1987, pp. 567-577.
    • (1987) Radiology , vol.164 , Issue.2 , pp. 567-577
    • Kalender, W.1    Hebele, R.2    Ebersberger, J.3
  • 5
    • 34250170177 scopus 로고    scopus 로고
    • The reduction of artifacts due to metal hip implants in ct-attenuation corrected pet images from hybrid pet/ct scanners
    • Jun
    • J. A. Kennedy, O. Israel, A. Frenkel, R. Bar-Shalom, and H. Azhari, "The reduction of artifacts due to metal hip implants in ct-attenuation corrected pet images from hybrid pet/ct scanners.", Med Biol Eng Comput, 45, Jun 2007, pp. 553-562.
    • (2007) Med Biol Eng Comput , vol.45 , pp. 553-562
    • Kennedy, J.A.1    Israel, O.2    Frenkel, A.3    Bar-Shalom, R.4    Azhari, H.5
  • 6
    • 0018306059 scopus 로고
    • A threshold selection method from gray-level histograms
    • Jan
    • N. Otsu, "A threshold selection method from gray-level histograms", IEEE Transactions on Systems, Man and Cybernetics, 9(1), Jan 1979, pp. 62-66.
    • (1979) IEEE Transactions on Systems, Man and Cybernetics , vol.9 , Issue.1 , pp. 62-66
    • Otsu, N.1
  • 7
    • 77950882012 scopus 로고    scopus 로고
    • Intraoperative 3d imaging with a mobile c-arm flat panel detector
    • C. Schmidgunst and R. Graumann, "Intraoperative 3d imaging with a mobile c-arm flat panel detector", 5. Jahrestagungder CURAC, 2006.
    • (2006) 5. Jahrestagung der CURAC
    • Schmidgunst, C.1    Graumann, R.2
  • 8
    • 34548331753 scopus 로고    scopus 로고
    • Calibration model of a dual gain flat panel detector for 2d and 3d x-ray imaging
    • C. Schmidgunst, D. Ritter, and E. W. Lang, "Calibration model of a dual gain flat panel detector for 2d and 3d x-ray imaging", Medical Physics, 34(9), 2007, pp. 3649-3664.
    • (2007) Medical Physics , vol.34 , Issue.9 , pp. 3649-3664
    • Schmidgunst, C.1    Ritter, D.2    Lang, E.W.3
  • 9
    • 12744273446 scopus 로고    scopus 로고
    • X-ray ct high-density artefact suppression in the presence of bones
    • J. Wei, L. Chen, G. A. Sandison, Y. Liang, and L. X. Xu, "X-ray ct high-density artefact suppression in the presence of bones", Physics in Medicine and Biology, 49(24), 2004, pp. 5407-5418.
    • (2004) Physics in Medicine and Biology , vol.49 , Issue.24 , pp. 5407-5418
    • Wei, J.1    Chen, L.2    Sandison, G.A.3    Liang, Y.4    Xu, L.X.5
  • 10
    • 21244471813 scopus 로고    scopus 로고
    • An adaptive approach to metal artifact reduction in helical computed tomography for radiation therapy treatment planning: Experimental and clinical studies
    • M. Yazdia, L. Gingras, and L. Beaulieu, "An adaptive approach to metal artifact reduction in helical computed tomography for radiation therapy treatment planning: Experimental and clinical studies", International Journal of Radiation Oncology*Biology*Physics, 62(4), 2005, pp. 1224 -1231.
    • (2005) International Journal of Radiation Oncology*Biology*Physics , vol.62 , Issue.4 , pp. 1224-1231
    • Yazdia, M.1    Gingras, L.2    Beaulieu, L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.