메뉴 건너뛰기




Volumn , Issue 550 CP, 2009, Pages

UHF monitoring of partial discharge in substation equipment using a novel multi-sensor cable loop

Author keywords

[No Author keywords available]

Indexed keywords

ARRAY OF SENSORS; DISTRIBUTION SUBSTATIONS; HIGH VOLTAGE SYSTEMS; HIGH-FREQUENCY MONITORING; MEASUREMENT HARDWARE; MEDIUM VOLTAGE; MULTI SENSOR; PARTIAL DISCHARGE LOCATION; PARTIAL DISCHARGE MEASUREMENTS; PARTIAL DISCHARGE MONITORING; SPECIFIC LOCATION; SUBSTATION EQUIPMENT; SWITCH GEARS; ULTRA-HIGH;

EID: 70450189749     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1049/cp.2009.1005     Document Type: Conference Paper
Times cited : (6)

References (11)
  • 1
    • 0020153587 scopus 로고
    • Electromagnetic techniques for fault and partial discharge location in gas-insulated cables and substations
    • July
    • S. A. Boggs. "Electromagnetic techniques for fault and partial discharge location in gas-insulated cables and substations", IEEE Transactions on Power Apparatus and Systems, vol. 101, no. 7, pp. 1935-1941, July 1982.
    • (1982) IEEE Transactions on Power Apparatus and Systems , vol.101 , Issue.7 , pp. 1935-1941
    • Boggs, S.A.1
  • 6
    • 17644409075 scopus 로고    scopus 로고
    • Partial discharge monitoring for power transformers using UHF sensors part 1: Sensors and signal interpretation
    • March/April
    • M. D. Judd, L. Yang, and I. Hunter. "Partial discharge monitoring for power transformers using UHF sensors part 1: Sensors and signal interpretation", IEEE Electrical Insulation Magazine, vol. 21, no. 2, pp. 5-14, March/April 2005.
    • (2005) IEEE Electrical Insulation Magazine , vol.21 , Issue.2 , pp. 5-14
    • Judd, M.D.1    Yang, L.2    Hunter, I.3
  • 7
    • 17644409075 scopus 로고    scopus 로고
    • Partial discharge monitoring for power transformers using UHF sensors part 2: Field experience
    • May/June
    • M. D. Judd, L. Yang, and I. Hunter. "Partial discharge monitoring for power transformers using UHF sensors part 2: Field experience", IEEE Electrical Insulation Magazine, vol. 21, no. 3, pp. 5-13, May/June 2005.
    • (2005) IEEE Electrical Insulation Magazine , vol.21 , Issue.3 , pp. 5-13
    • Judd, M.D.1    Yang, L.2    Hunter, I.3
  • 9
    • 23944440123 scopus 로고    scopus 로고
    • Radiometric location of partial discharge sources on energized high-voltage plant
    • July
    • Philip J. Moore, Iliana E. Portugues, and Ian A. Glover. "Radiometric location of partial discharge sources on energized high-voltage plant". IEEE Transactions on Power Delivery, vol. 20, no. 3, pp. 2264-2272, July 2005.
    • (2005) IEEE Transactions on Power Delivery , vol.20 , Issue.3 , pp. 2264-2272
    • Moore, P.J.1    Portugues, I.E.2    Glover, I.A.3
  • 10
    • 70450153911 scopus 로고    scopus 로고
    • National Grid Company plc, Capacitive couplers for UHF partial discharge monitoring, Technical Guidance Note: TGN(T)121, Issue 1, January 1997.
    • National Grid Company plc, "Capacitive couplers for UHF partial discharge monitoring", Technical Guidance Note: TGN(T)121, Issue 1, January 1997.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.