Investigation of radiometric partial discharge detection for use in switched HVDC testing

Author keywords

Diagnostic expert systems; HVDC converters; Partial discharges; UHF radiometry

Indexed keywords

ELECTRIC REACTORS; ELECTROMAGNETISM; HVDC POWER TRANSMISSION; RADIOMETRY; SWITCHING; UHF DEVICES;

EID: 35348867448     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/pes.2006.1709200     Document Type: Conference Paper
Times cited : (17)

References (14)
  • 1
    • 0023983411 scopus 로고
    • Diagnostic measurements at UHF in gas insulated substations
    • Pt. C, March
    • B. F. Hampton and R. J. Meats, "Diagnostic measurements at UHF in gas insulated substations", IEE Proc, Vol. 135, Pt. C, No. 2, pp. 137-144, March 1988.
    • (1988) IEE Proc , vol.135 , Issue.2 , pp. 137-144
    • Hampton, B.F.1    Meats, R.J.2
  • 3
    • 35348918562 scopus 로고    scopus 로고
    • Joint Working Group 33/23.12, Insulation co-ordination of GIS: Return of experience, on site tests and diagnostic techniques, Electra (CIGRE), No. 176, pp. 67-97, February 1998.
    • Joint Working Group 33/23.12, "Insulation co-ordination of GIS: Return of experience, on site tests and diagnostic techniques", Electra (CIGRE), No. 176, pp. 67-97, February 1998.
  • 4
    • 0036937490 scopus 로고    scopus 로고
    • Intelligent condition monitoring and asset management: Partial discharge monitoring for power transformers
    • December
    • M. D. Judd, S. D. J. McArthur, J. R. McDonald and O. Farish, "Intelligent condition monitoring and asset management: Partial discharge monitoring for power transformers", IEE Power Engineering Journal, Vol. 16, No. 6, pp. 297-304, December 2002
    • (2002) IEE Power Engineering Journal , vol.16 , Issue.6 , pp. 297-304
    • Judd, M.D.1    McArthur, S.D.J.2    McDonald, J.R.3    Farish, O.4
  • 6
    • 17644409075 scopus 로고    scopus 로고
    • Partial discharge monitoring for power transformers using UHF sensors Part 1: Sensors and signal interpretation
    • M. D. Judd, L. Yang and I. B. B. Hunter, "Partial discharge monitoring for power transformers using UHF sensors Part 1: Sensors and signal interpretation", IEEE Insulation Magazine 2005.
    • (2005) IEEE Insulation Magazine
    • Judd, M.D.1    Yang, L.2    Hunter, I.B.B.3
  • 7
    • 20444382334 scopus 로고    scopus 로고
    • Partial discharge monitoring for power transformers using UHF sensors Part 2: Field Experience
    • M. D. Judd, L. Yang and I. B. B. Hunter, "Partial discharge monitoring for power transformers using UHF sensors Part 2: Field Experience", IEEE Insulation Magazine 2005.
    • (2005) IEEE Insulation Magazine
    • Judd, M.D.1    Yang, L.2    Hunter, I.B.B.3
  • 8
    • 0036079176 scopus 로고    scopus 로고
    • Comparative investigations on UHF and acoustic PD detection sensitivity in transformers
    • Boston, pp, April
    • K. Raja and T. Floribert, "Comparative investigations on UHF and acoustic PD detection sensitivity in transformers", Conf. Record of the 2002 IEEE Int. Symp. on Electrical Insulation, Boston, pp. 150-153, April 2002.
    • (2002) Conf. Record of the 2002 IEEE Int. Symp. on Electrical Insulation , pp. 150-153
    • Raja, K.1    Floribert, T.2
  • 9
    • 0036759963 scopus 로고    scopus 로고
    • Recognition of discharge sources using UHF PD signatures
    • Sep/Oct
    • K. Raja, F. Devaux and S. Lelaidier, "Recognition of discharge sources using UHF PD signatures", IEEE Electrical Insulation Magazine, Vol. 18, No. 5, pp. 8-14, Sep/Oct 2002.
    • (2002) IEEE Electrical Insulation Magazine , vol.18 , Issue.5 , pp. 8-14
    • Raja, K.1    Devaux, F.2    Lelaidier, S.3
  • 10
    • 28744438034 scopus 로고    scopus 로고
    • Procedure for identification and localization of dangerous PD sources in power transformers
    • October
    • J. Fuhr, "Procedure for identification and localization of dangerous PD sources in power transformers", IEEE Trans. Dielectrics and Electrical Insulation, Vol. 12, No. 5, October 2005.
    • (2005) IEEE Trans. Dielectrics and Electrical Insulation , vol.12 , Issue.5
    • Fuhr, J.1
  • 11
    • 17744364920 scopus 로고    scopus 로고
    • Propagation characteristics of UHF signals in transformers for locating partial discharge sources
    • Delft, August
    • L. Yang and M. D. Judd, "Propagation characteristics of UHF signals in transformers for locating partial discharge sources", Proc. 13th Int. Symp. on High Voltage Engineering, Delft, August 2003.
    • (2003) Proc. 13th Int. Symp. on High Voltage Engineering
    • Yang, L.1    Judd, M.D.2
  • 12
    • 0032131431 scopus 로고    scopus 로고
    • A pulsed GTEM system for UHF sensor calibration
    • August
    • M. D. Judd and O. Farish, "A pulsed GTEM system for UHF sensor calibration", IEEE Trans. Instrumentation and Measurement, Vol. 47, No. 4, pp. 875-880, August 1998.
    • (1998) IEEE Trans. Instrumentation and Measurement , vol.47 , Issue.4 , pp. 875-880
    • Judd, M.D.1    Farish, O.2
  • 14
    • 35348863439 scopus 로고    scopus 로고
    • National Grid Company, Capacitive couplers for UHF partial discharge monitoring, Technical Guidance Note: TGN(T)121, Issue 1, January 1997.
    • National Grid Company, "Capacitive couplers for UHF partial discharge monitoring", Technical Guidance Note: TGN(T)121, Issue 1, January 1997.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.