메뉴 건너뛰기




Volumn 24, Issue 3, 2009, Pages 153-162

Clinical evaluation of minimized extracorporeal circulation in high-risk coronary revascularization: Impact on air handling, inflammation, hemodilution and myocardial function

Author keywords

Cardiopulmonary bypass; CPB inflammatory response; Minimal extracorporeal circulation

Indexed keywords

CD11B ANTIGEN; CD18 ANTIGEN; COMPLEMENT COMPONENT C3A; CREATINE KINASE; CREATINE KINASE MB; HEMOGLOBIN; INTERLEUKIN 6;

EID: 70450188140     PISSN: 02676591     EISSN: None     Source Type: Journal    
DOI: 10.1177/0267659109346664     Document Type: Conference Paper
Times cited : (45)

References (22)
  • 2
    • 35348860862 scopus 로고    scopus 로고
    • Minimal extracorporeal circulation is a promising technique for coronary artery bypass grafting
    • Immer FF, Ackermann A., Gygax E., et al. Minimal extracorporeal circulation is a promising technique for coronary artery bypass grafting. Ann Thorac Surg 2007; 84: 1515-1521.
    • (2007) Ann Thorac Surg , vol.84 , pp. 1515-1521
    • Immer, F.F.1    Ackermann, A.2    Gygax, E.3
  • 3
    • 29244455014 scopus 로고    scopus 로고
    • Comparison of conventional extracorporeal circulation and minimal extracorporeal circulation with respect to microbubbles and microembolic signals
    • Perthel M., Kseibi S., Sagebiel F., Alken A., Laas J. Comparison of conventional extracorporeal circulation and minimal extracorporeal circulation with respect to microbubbles and microembolic signals. Perfusion 2005; 20(6): 329-333.
    • (2005) Perfusion , vol.20 , Issue.6 , pp. 329-333
    • Perthel, M.1    Kseibi, S.2    Sagebiel, F.3    Alken, A.4    Laas, J.5
  • 4
    • 0027368320 scopus 로고
    • Flow cytometric determination of CD11b upregulation in vivo
    • Repo H., Jansson SE, Leirisalo-Repo M. Flow cytometric determination of CD11b upregulation in vivo. J Immunol Methods 1993; 164: 193-202.
    • (1993) J Immunol Methods , vol.164 , pp. 193-202
    • Repo, H.1    Jansson, S.E.2    Leirisalo-Repo, M.3
  • 5
    • 70450170274 scopus 로고    scopus 로고
    • Air handling and cardiac surgery: EDAC® quantifier introduces new concepts in solving an old problem
    • Gunaydin S. Air handling and cardiac surgery: EDAC® quantifier introduces new concepts in solving an old problem. AmSECT Today 2008; 11(10): 11.
    • (2008) AmSECT Today , vol.11 , Issue.10 , pp. 11
    • Gunaydin, S.1
  • 6
    • 0034066530 scopus 로고    scopus 로고
    • Blood compatible aspects of poly(2-methoxyethylacrylate) relationship between protein adsorption and platelet adhesion on PMEA surface
    • Tanaka M., Motomura T., Kawada M. et al. Blood compatible aspects of poly(2-methoxyethylacrylate) relationship between protein adsorption and platelet adhesion on PMEA surface. Biomaterials 2000; 21: 1471-1481.
    • (2000) Biomaterials , vol.21 , pp. 1471-1481
    • Tanaka, M.1    Motomura, T.2    Kawada, M.3
  • 7
    • 0037312501 scopus 로고    scopus 로고
    • Inflammatory response to cardiopulmonary bypass
    • Levy JH, Tanaka KA Inflammatory response to cardiopulmonary bypass. Ann Thorac Surg 2003; 75: S715-S720.
    • (2003) Ann Thorac Surg , vol.75
    • Levy, J.H.1    Tanaka, K.A.2
  • 8
    • 45249102029 scopus 로고    scopus 로고
    • Coronary artery bypass surgery using the mini-extracorporeal circulation system: A Spanish unit's experience
    • Zamora E., Delgado L., Castro MA, et al. Coronary artery bypass surgery using the mini-extracorporeal circulation system: A Spanish unit's experience. Rev Esp Cardiol 2008; 61(4): 376-381.
    • (2008) Rev Esp Cardiol , vol.61 , Issue.4 , pp. 376-381
    • Zamora, E.1    Delgado, L.2    Castro, M.A.3
  • 9
    • 0030271403 scopus 로고    scopus 로고
    • Centrifugal pump and heparin coating improves cardiopulmonary bypass biocompatibility
    • Moen O., Fosse E., Dregelid E., et al. Centrifugal pump and heparin coating improves cardiopulmonary bypass biocompatibility. Ann Thorac Surg 1996; 62: 1134-1140.
    • (1996) Ann Thorac Surg , vol.62 , pp. 1134-1140
    • Moen, O.1    Fosse, E.2    Dregelid, E.3
  • 10
    • 0033044122 scopus 로고    scopus 로고
    • Comparative study of biocompatibility between open circuit and closed circuit in cardiopulmonary bypass
    • Nishida H., Aomi S., Tomizawa Y., et al. Comparative study of biocompatibility between open circuit and closed circuit in cardiopulmonary bypass. Artif Organs 1999; 23: 547-551.
    • (1999) Artif Organs , vol.23 , pp. 547-551
    • Nishida, H.1    Aomi, S.2    Tomizawa, Y.3
  • 11
    • 28344447156 scopus 로고    scopus 로고
    • Miniaturized cardiopulmonary bypass in coronary artery bypass surgery: Marginal impact on inflammation and coagulation but loss of safety margins
    • Nollert G., Schwabenland I., Maktav D., et al. Miniaturized cardiopulmonary bypass in coronary artery bypass surgery: Marginal impact on inflammation and coagulation but loss of safety margins. Ann Thorac Surg 2005; 80: 2326-2332.
    • (2005) Ann Thorac Surg , vol.80 , pp. 2326-2332
    • Nollert, G.1    Schwabenland, I.2    Maktav, D.3
  • 12
    • 4444333445 scopus 로고    scopus 로고
    • Mini extracorporeal circuit for coronary artery bypass grafting: Initial clinical and biochemical results: A comparison with conventional and off-pump coronary artery bypass grafts concerning global oxidative stress and alveolar function
    • van Boven WJ, Gerritsen WB, Waanders FG, Haas FJ, Aarts LP Mini extracorporeal circuit for coronary artery bypass grafting: Initial clinical and biochemical results: A comparison with conventional and off-pump coronary artery bypass grafts concerning global oxidative stress and alveolar function. Perfusion 2004; 19: 239-246.
    • (2004) Perfusion , vol.19 , pp. 239-246
    • van Boven, W.J.1    Gerritsen, W.B.2    Waanders, F.G.3    Haas, F.J.4    Aarts, L.P.5
  • 13
    • 0035183320 scopus 로고    scopus 로고
    • MAST system: A new condensed cardiopulmonary bypass circuit for adult cardiac surgery
    • McCusker K., Vijay V., DeBois W., Helm R., Sisto D. MAST system: A new condensed cardiopulmonary bypass circuit for adult cardiac surgery. Perfusion 2001; 16(6): 447-452.
    • (2001) Perfusion , vol.16 , Issue.6 , pp. 447-452
    • McCusker, K.1    Vijay, V.2    DeBois, W.3    Helm, R.4    Sisto, D.5
  • 14
    • 18844434720 scopus 로고    scopus 로고
    • Evaluation of a new condensed extracorporeal circuit for cardiac surgery: A prospective randomized clinical pilot study
    • Fransen EJ, Ganushchak YM, Vijay V., de Jong DS, Buurman WA, Maessen JG Evaluation of a new condensed extracorporeal circuit for cardiac surgery: A prospective randomized clinical pilot study. Perfusion 2005; 20: 91-99.
    • (2005) Perfusion , vol.20 , pp. 91-99
    • Fransen, E.J.1    Ganushchak, Y.M.2    Vijay, V.3    de Jong, D.S.4    Buurman, W.A.5    Maessen, J.G.6
  • 15
    • 50649114634 scopus 로고    scopus 로고
    • Reduction of blood coagulation and monocyte-platelet interaction following the use of a minimal extracorporeal circulation system (Synergy®) in coronary artery bypass grafting
    • Farneti PA, Sbrana S., Spiller D., et al. Reduction of blood coagulation and monocyte-platelet interaction following the use of a minimal extracorporeal circulation system (Synergy®) in coronary artery bypass grafting. Perfusion 2008; 23: 49-56.
    • (2008) Perfusion , vol.23 , pp. 49-56
    • Farneti, P.A.1    Sbrana, S.2    Spiller, D.3
  • 16
    • 34447315316 scopus 로고    scopus 로고
    • Minimal cardiopulmonary bypass attenuates neutrophil activation and cytokine release in coronary artery bypass grafting
    • Ohata T., Mitsuno M., Yamamura M., et al. Minimal cardiopulmonary bypass attenuates neutrophil activation and cytokine release in coronary artery bypass grafting. J Artif Organs 2007; 10: 92-95.
    • (2007) J Artif Organs , vol.10 , pp. 92-95
    • Ohata, T.1    Mitsuno, M.2    Yamamura, M.3
  • 17
    • 0037818560 scopus 로고    scopus 로고
    • The effect of haemodilution on blood/biomaterial contact-mediated CD11b expression on neutrophils: Ex vivo studies
    • Gourlay T., Samartzis I., Taylor KM The effect of haemodilution on blood/ biomaterial contact-mediated CD11b expression on neutrophils: Ex vivo studies. Perfusion 2003; 18: 87-93.
    • (2003) Perfusion , vol.18 , pp. 87-93
    • Gourlay, T.1    Samartzis, I.2    Taylor, K.M.3
  • 18
    • 34247179501 scopus 로고    scopus 로고
    • Attenuated renal and intestinal injury after use of a mini-cardiopulmonary bypass system
    • Huybregts RAJM, Morariu AM, Rakhorst G., et al. Attenuated renal and intestinal injury after use of a mini-cardiopulmonary bypass system. Ann Thorac Surg 2007; 83: 1760-1767.
    • (2007) Ann Thorac Surg , vol.83 , pp. 1760-1767
    • Huybregts, R.A.J.M.1    Morariu, A.M.2    Rakhorst, G.3
  • 19
    • 33745313327 scopus 로고    scopus 로고
    • Influence of hematocrit and pump prime on cerebral oxygen saturation in on-pump coronary revascularization
    • McCusker K., Chalafant A., de Foe G., Gunaydin S., Vijay V. Influence of hematocrit and pump prime on cerebral oxygen saturation in on-pump coronary revascularization. Perfusion 2006; 21(3): 149-55.
    • (2006) Perfusion , vol.21 , Issue.3 , pp. 149-155
    • McCusker, K.1    Chalafant, A.2    de Foe, G.3    Gunaydin, S.4    Vijay, V.5
  • 20
    • 31544462102 scopus 로고    scopus 로고
    • Clinical performance and biocompatibility of novel hyaluronan-based heparin-bonded extracorporeal circuits
    • Gunaydin S., McCusker K., Vijay V. Clinical performance and biocompatibility of novel hyaluronan-based heparin-bonded extracorporeal circuits. J Extracorp Technol 2005; 37(3): 290-295.
    • (2005) J Extracorp Technol , vol.37 , Issue.3 , pp. 290-295
    • Gunaydin, S.1    McCusker, K.2    Vijay, V.3
  • 21
    • 2342667614 scopus 로고    scopus 로고
    • Clinical significance of coated extracorporeal circuits: A review of novel technologies
    • Gunaydin S. Clinical significance of coated extracorporeal circuits: A review of novel technologies. Perfusion 2004; 19: S33-S41.
    • (2004) Perfusion , vol.19
    • Gunaydin, S.1
  • 22
    • 0036712911 scopus 로고    scopus 로고
    • Clinical performance and biocompatibility of poly (2-methoxyethylacrylate) coated extracorporeal circuits
    • Gunaydin S., Farsak B., Kocakulak M., Sari T., Yorgancioglu C., Zorlutuna Y. Clinical performance and biocompatibility of poly (2-methoxyethylacrylate) coated extracorporeal circuits. Ann Thorac Surg. 2002; 74(3): 819-824.
    • (2002) Ann Thorac Surg , vol.74 , Issue.3 , pp. 819-824
    • Gunaydin, S.1    Farsak, B.2    Kocakulak, M.3    Sari, T.4    Yorgancioglu, C.5    Zorlutuna, Y.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.