메뉴 건너뛰기




Volumn 37, Issue 3, 2005, Pages 290-295

Clinical performance and biocompatibility of novel hyaluronan-based heparin-bonded extracorporeal circuits

Author keywords

Cardiopulmonary bypass, coated materials, biocompatibility; Membrane oxygenators, extracorporeal circulation

Indexed keywords

ALBUMIN; BIOMATERIAL; COMPLEMENT COMPONENT C3A; FIBRINOGEN; HEPARIN; HYALURONIC ACID; INTERLEUKIN 2; LIQUEMINE; PROTAMINE;

EID: 31544462102     PISSN: 00221058     EISSN: 29698960     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (12)

References (18)
  • 3
    • 0029949174 scopus 로고    scopus 로고
    • Blood-interaction performance of differently sulphated hyaluronic acids
    • Magnani A, Albanese A, Lamponi S, Barbucci R. Blood-interaction performance of differently sulphated hyaluronic acids. Thrombosis Research. 1996;81:383-95.
    • (1996) Thrombosis Research , vol.81 , pp. 383-395
    • Magnani, A.1    Albanese, A.2    Lamponi, S.3    Barbucci, R.4
  • 5
    • 0034066530 scopus 로고    scopus 로고
    • Blood compatible aspects of poly(2-methoxyethylacrylate) relationship between protein adsorption and platelet adhesion on PMEA surface
    • Tanaka M, Motomura T, Kawada M, et al. Blood compatible aspects of poly(2-methoxyethylacrylate) relationship between protein adsorption and platelet adhesion on PMEA surface. Biomaterials. 2000;21:1471-81.
    • (2000) Biomaterials , vol.21 , pp. 1471-1481
    • Tanaka, M.1    Motomura, T.2    Kawada, M.3
  • 6
    • 0031282091 scopus 로고    scopus 로고
    • Biocompatibility and enzymatic degradation studies on sulphated hyaluronic acid derivatives
    • Abatangelo G, Barbucci R, Brun P, Lamponi S. Biocompatibility and enzymatic degradation studies on sulphated hyaluronic acid derivatives. Biomaterials. 1997;18:1411-5.
    • (1997) Biomaterials , vol.18 , pp. 1411-1415
    • Abatangelo, G.1    Barbucci, R.2    Brun, P.3    Lamponi, S.4
  • 7
    • 0023511675 scopus 로고
    • Biocompatible surfaces prepared by immobilized heparin or hyaluronate
    • Larsson R. Biocompatible surfaces prepared by immobilized heparin or hyaluronate. Acta Otolaryngol. 1987;442:S44-9.
    • (1987) Acta Otolaryngol , vol.442
    • Larsson, R.1
  • 8
    • 0028485139 scopus 로고
    • Resistance of hyaluronate coatings to hyaluronidase
    • Lowry KL, Beavers EM. Resistance of hyaluronate coatings to hyaluronidase. J Biomed Mater Res. 1994;28:861-4.
    • (1994) J Biomed Mater Res , vol.28 , pp. 861-864
    • Lowry, K.L.1    Beavers, E.M.2
  • 9
    • 0033525415 scopus 로고    scopus 로고
    • Effects of Photochemically immobilized polymer coatings on protein adsorption, cell adhesion, and foreign-body reaction to silicone rubber
    • DeFife KM, Shive MS, Hagen KM, Clapper DL, Anderson JM. Effects of Photochemically immobilized polymer coatings on protein adsorption, cell adhesion, and foreign-body reaction to silicone rubber. J Biomed Mater Res. 1999;44:289-307.
    • (1999) J Biomed Mater Res , vol.44 , pp. 289-307
    • Defife, K.M.1    Shive, M.S.2    Hagen, K.M.3    Clapper, D.L.4    Anderson, J.M.5
  • 10
    • 0032857242 scopus 로고    scopus 로고
    • The effects of heparin coating of oxygenator fibers on platelet adhesion and protein adsorption
    • Niimi Y, Ichinose F, Ishiguro Y, et al. The effects of heparin coating of oxygenator fibers on platelet adhesion and protein adsorption. Anesth Analg. 1999;89:573-7.
    • (1999) Anesth Analg , vol.89 , pp. 573-577
    • Niimi, Y.1    Ichinose, F.2    Ishiguro, Y.3
  • 11
    • 0033143726 scopus 로고    scopus 로고
    • Evaluation of heparin coated circuits with full heparin dose strategy
    • Sinci V, Kalaycioglu S, Gunaydin S, et al. Evaluation of heparin coated circuits with full heparin dose strategy. Ann Thorac Cardiovasc Surg. 1999;5:156-63.
    • (1999) Ann Thorac Cardiovasc Surg , vol.5 , pp. 156-163
    • Sinci, V.1    Kalaycioglu, S.2    Gunaydin, S.3
  • 12
    • 0036712911 scopus 로고    scopus 로고
    • Clinical performance and biocompatibility of poly (2- methoxyethylacrylate) coated extracorporeal circuits
    • Gunaydin S, Farsak B, Kocakulak M, Sari T, Yorgancioglu C, Zorlutuna Y. Clinical performance and biocompatibility of poly (2-methoxyethylacrylate) coated extracorporeal circuits. Ann Thorac Surg. 2002;74:819-24.
    • (2002) Ann Thorac Surg , vol.74 , pp. 819-824
    • Gunaydin, S.1    Farsak, B.2    Kocakulak, M.3    Sari, T.4    Yorgancioglu, C.5    Zorlutuna, Y.6
  • 13
    • 18744374871 scopus 로고    scopus 로고
    • Investigation of blood compatibility of PMEA coated extracorporeal circuits
    • Kocakulak M, Kocum C, Saber R, et al. Investigation of blood compatibility of PMEA coated extracorporeal circuits. J Bioact Compat Poly. 2002;17:343-56.
    • (2002) J Bioact Compat Poly , vol.17 , pp. 343-356
    • Kocakulak, M.1    Kocum, C.2    Saber, R.3
  • 14
    • 2342667614 scopus 로고    scopus 로고
    • Clinical significance of coated extracorporeal circuits: A review of novel technologies
    • Gunaydin S. Clinical significance of coated extracorporeal circuits: A review of novel technologies. Perfusion. 2004;19:S33-41.
    • (2004) Perfusion , vol.19
    • Gunaydin, S.1
  • 15
    • 0034783976 scopus 로고    scopus 로고
    • Biocompatibility of Trillium biopassive surface coated oxygenator during cardiopulmonary bypass
    • Stammers AH. Biocompatibility of Trillium biopassive surface coated oxygenator during cardiopulmonary bypass. J Cardiothorac Vase Anesth. 2001;15:539-41.
    • (2001) J Cardiothorac Vase Anesth , vol.15 , pp. 539-541
    • Stammers, A.H.1
  • 16
    • 4444326961 scopus 로고    scopus 로고
    • Emerging technologies in biocompatible surface modifying additives: Quest for physiologic cardiopulmonary bypass
    • Gunaydin S. Emerging technologies in biocompatible surface modifying additives: Quest for physiologic cardiopulmonary bypass. Curr Med Chem-Cardiovasc Hematologic Agents. 2004;2:295-302.
    • (2004) Curr Med Chem-Cardiovasc Hematologic Agents , vol.2 , pp. 295-302
    • Gunaydin, S.1
  • 17
    • 0034830566 scopus 로고    scopus 로고
    • Biomaterial development for cardiopulmonary bypass
    • Gourlay T. Biomaterial development for cardiopulmonary bypass. Perfusion. 2001;16:381-90.
    • (2001) Perfusion , vol.16 , pp. 381-390
    • Gourlay, T.1
  • 18
    • 0037278614 scopus 로고    scopus 로고
    • Recent advances in biocompatible surface-modifying additives for cardiopulmonary bypass
    • Vijay V, McCusker K. Recent advances in biocompatible surface-modifying additives for cardiopulmonary bypass. Perfusion. 2003;18: S41-5.
    • (2003) Perfusion , vol.18
    • Vijay, V.1    McCusker, K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.