메뉴 건너뛰기




Volumn 80, Issue 7, 2009, Pages 1033-1035

Letters to the editor

Author keywords

[No Author keywords available]

Indexed keywords

BONE REMODELING; COMPUTER SIMULATION; DENTAL CARE; FINITE ELEMENT ANALYSIS; HUMAN; JAW; MATERIALS TESTING; NOTE; STANDARD; TOOTH IMPLANTATION; TOOTH PROSTHESIS;

EID: 70449731154     PISSN: 00223492     EISSN: None     Source Type: Journal    
DOI: 10.1902/jop.2009.090070     Document Type: Letter
Times cited : (7)

References (19)
  • 1
    • 55749100339 scopus 로고    scopus 로고
    • Effect of microthreads and platform switching on crestal bone stress levels: afinite element analysis
    • Schrotenboer J, Tsao YP, Kinariwala V, Wang HL. Effect of microthreads and platform switching on crestal bone stress levels: A finite element analysis. J Periodontol 2008;79:2166-2172.
    • (2008) J Periodontol , vol.79 , pp. 2166-2172
    • Schrotenboer, J.1    Tsao, Y.P.2    Kinariwala, V.3    Wang, H.L.4
  • 2
    • 0016170096 scopus 로고
    • The mechanical properties of cortical bone
    • Reilly DT, Burstein AH. The mechanical properties of cortical bone. J Bone Joint Surg Am 1974;56:1001-1022.
    • (1974) J Bone Joint Surg Am , vol.56 , pp. 1001-1022
    • Reilly, D.T.1    Burstein, A.H.2
  • 3
    • 0036328669 scopus 로고    scopus 로고
    • Effect of micro-roughness produced by tio2blasting mdashtensile testing of bone attachment by using coin-shaped implants
    • Rønold HJ, Ellingsen JE. Effect of micro-roughness produced by TiO2blasting mdashtensile testing of bone attachment by using coin-shaped implants. Biomate-rials 2002;23:4211-4219.
    • (2002) Biomaterials , vol.23 , pp. 4211-4219
    • Rønold, H.J.1    Ellingsen, J.E.2
  • 6
    • 0033212422 scopus 로고    scopus 로고
    • The implant neck: smooth or provided with retention elements
    • Hansson S. The implant neck: Smooth or provided with retention elements. A biomechanical approach. Clin Oral Implants Res 1999;10:394-405.
    • (1999) A biomechanical approach. Clin Oral Implants Res , vol.10 , pp. 394-405
    • Hansson, S.1
  • 7
    • 0042625004 scopus 로고    scopus 로고
    • The implant thread as a retention element in cortical bone: the effect of thread size and thread profile: afinite element study
    • Hansson S, Werke M. The implant thread as a retention element in cortical bone: The effect of thread size and thread profile: A finite element study. J Biomech 2003; 36:1247-1258.
    • (2003) J Biomech , vol.36 , pp. 1247-1258
    • Hansson, S.1    Werke, M.2
  • 8
    • 0035235831 scopus 로고    scopus 로고
    • Effects of implant design and surface on bone regeneration and implant stability: an experimental study in the dog mandible
    • Rasmusson L, Kahnberg KE, Tan A. Effects of implant design and surface on bone regeneration and implant stability: An experimental study in the dog mandible. Clin Implant Dent Relat Res 2001;3:2-8.
    • (2001) Clin Implant Dent Relat Res , vol.3 , pp. 2-8
    • Rasmusson, L.1    Kahnberg, K.E.2    Tan, A.3
  • 9
    • 33748933219 scopus 로고    scopus 로고
    • Tissue characteristics at microthreaded implants: an experimental study in dogs
    • Abrahamsson I, Berglundh T. Tissue characteristics at microthreaded implants: An experimental study in dogs. Clin Implant Dent Relat Res 2006;8:107-113.
    • (2006) Clin Implant Dent Relat Res , vol.8 , pp. 107-113
    • Abrahamsson, I.1    Berglundh, T.2
  • 10
    • 23844502801 scopus 로고    scopus 로고
    • Bone reactions to longstanding functional load at implants: an experimental study in dogs
    • Berglundh T, Abrahamsson I, Lindhe J. Bone reactions to longstanding functional load at implants: An experimental study in dogs. J Clin Periodontol 2005; 32:925-932.
    • (2005) J Clin Periodontol , vol.32 , pp. 925-932
    • Berglundh, T.1    Abrahamsson, I.2    Lindhe, J.3
  • 11
    • 0026921680 scopus 로고
    • Fixture design and overload influence marginal bone loss and fixture success in the branemark system
    • Quirynen M, Naert I, van Steenberghe D. Fixture design and overload influence marginal bone loss and fixture success in the Branemark system. Clin Clin Oral Implants Res 1992: 3: 104-111.
    • (1992) Clin Oral Implants Res , vol.3 , pp. 104-111
    • Quirynen, M.1    Naert, I.2    Van Steenberghe, D.3
  • 12
    • 0029445733 scopus 로고
    • Single-tooth replacement by osseointegrated branemark implants
    • Engquist B, Nilson H, Astrand P. Single-tooth replacement by osseointegrated Braring;nemark implants. Clin Oral Implants Res 1995;6:238-245.
    • (1995) Clin Oral Implants Res , vol.6 , pp. 238-245
    • Engquist, B.1    Nilson, H.2    Astrand, P.3
  • 13
    • 0029175459 scopus 로고
    • Implants for single-tooth replacements. a clinical and experimental study on the brånemark ceraone system
    • Andersson B. Implants for single-tooth replacements. A clinical and experimental study on the Brånemark CeraOne System. Swed Dent J Suppl 1995;108:1-41.
    • (1995) Swed Dent J Suppl , vol.108 , pp. 1-41
    • Andersson, B.1
  • 14
    • 0030155566 scopus 로고    scopus 로고
    • Marginal Bone Levels At Brånemark System Implants Used for Single-tooth Restorations. The influence of implant design and anatomical region
    • Malevez C, Hermans N, Daelemans P. Marginal bone levels at Brånemark system implants used for single-tooth restorations. The influence of implant design and anatomical region. Clin Oral Implants Res 1996;7: 162-169.
    • (1996) Clin Oral Implants Res , vol.7 , pp. 162-169
    • Malevez, C.1    Hermans, N.2    Daelemans, P.3
  • 15
    • 0034172846 scopus 로고    scopus 로고
    • A 5-year prospective study of astra single-tooth implants
    • Palmer RM, Palmer PJ, Smith BJ. A 5-year prospective study of Astra single-tooth implants. Clin Oral Implants Res 2000;11:179-182.
    • (2000) Clin Oral Implants Res , vol.11 , pp. 179-182
    • Palmer, R.M.1    Palmer, P.J.2    Smith, B.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.