Volumn 38, Issue 5, 2009, Pages 610-615

Comparison of Ankle-Brachial Index Measured by an Automated Oscillometric Apparatus with that by Standard Doppler Technique in Vascular Patients

Author keywords

Atherosclerosis; Blood pressure; Oscillometry; Peripheral arterial disease; Vascular diseases

Indexed keywords

ADULT; AGED; ANKLE BRACHIAL INDEX; ANKLE PRESSURE; ARTICLE; ATHEROSCLEROSIS; AUTOMATION; BLOOD PRESSURE MEASUREMENT; CLAUDICATION; DEVICE; DIABETES MELLITUS; DIAGNOSTIC ACCURACY; DOPPLER ECHOGRAPHY; HUMAN; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; MEASUREMENT; OSCILLOMETRY; PERIPHERAL OCCLUSIVE ARTERY DISEASE; PERIPHERAL VASCULAR DISEASE; PRIORITY JOURNAL; REPRODUCIBILITY; SPHYGMOMANOMETER; ULTRASOUND; ANKLE; ARM; BLOOD PRESSURE; BRACHIAL ARTERY; COMPARATIVE STUDY; DOPPLER FLOWMETRY; ECHOGRAPHY; EVALUATION; INSTRUMENTATION; MIDDLE AGED; PATHOPHYSIOLOGY; PREDICTION AND FORECASTING; SENSITIVITY AND SPECIFICITY; VASCULARIZATION;

EID: 70449711161     PISSN: 10785884     EISSN: 15322165     Source Type: Journal    
DOI: 10.1016/j.ejvs.2009.07.004     Document Type: Article
Times cited : (41)

References (13)
  • 2
    • 33748967507 scopus 로고    scopus 로고
    • Risk of mortality and cardiovascular disease associated with the ankle-brachial index: systematic review
    • Heald C.L., Fowkes F.G.R., Murray G.D., and Price J.F. Risk of mortality and cardiovascular disease associated with the ankle-brachial index: systematic review. Atheros 189 1 (2006) 61-69
    • (2006) Atheros , vol.189 , Issue.1 , pp. 61-69
    • Heald, C.L.1    Fowkes, F.G.R.2    Murray, G.D.3    Price, J.F.4
  • 3
    • 0034602617 scopus 로고    scopus 로고
    • Prevention conference V: beyond secondary prevention: identifying the high-risk patient for primary prevention: noninvasive tests of atherosclerotic burden: writing group III
    • Greenland P., Abrams J., Aurigemma G.P., Bond M.G., Clark L.T., Criqui M.H., et al. Prevention conference V: beyond secondary prevention: identifying the high-risk patient for primary prevention: noninvasive tests of atherosclerotic burden: writing group III. Circ 101 (2000) E16-E22
    • (2000) Circ , vol.101
    • Greenland, P.1    Abrams, J.2    Aurigemma, G.P.3    Bond, M.G.4    Clark, L.T.5    Criqui, M.H.6
  • 4
    • 34748924577 scopus 로고    scopus 로고
    • European guidelines on cardiovascular disease prevention in clinical practice: executive summary
    • Graham I. European guidelines on cardiovascular disease prevention in clinical practice: executive summary. Atheros 194 1 (2007) 1-45
    • (2007) Atheros , vol.194 , Issue.1 , pp. 1-45
    • Graham, I.1
  • 5
    • 31744451141 scopus 로고    scopus 로고
    • Automated oscillometric determination of the ankle-brachial index provides accuracy necessary for office practice
    • Beckman J.A., Higgins C.O., and Gerhard-Herman M. Automated oscillometric determination of the ankle-brachial index provides accuracy necessary for office practice. Hypert 47 (2006) 35-38
    • (2006) Hypert , vol.47 , pp. 35-38
    • Beckman, J.A.1    Higgins, C.O.2    Gerhard-Herman, M.3
  • 6
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland J.M., and Altman D.G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1 8476 (1986) 307-310
    • (1986) Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 7
    • 0018974024 scopus 로고
    • Statistics and ethics in medical research: III how large a sample?
    • Altman D.G. Statistics and ethics in medical research: III how large a sample?. B Med J 281 (1980) 1336-1338
    • (1980) B Med J , vol.281 , pp. 1336-1338
    • Altman, D.G.1
  • 8
    • 44849105111 scopus 로고    scopus 로고
    • Doppler ultrasound compared with strain gauge for measurement of systolic ankle blood pressure
    • Joensen J.B., Juul S., Abrahamsen J., Henneberg E.W., and Lindholt J.S. Doppler ultrasound compared with strain gauge for measurement of systolic ankle blood pressure. Angio 59 3 (2008) 296-300
    • (2008) Angio , vol.59 , Issue.3 , pp. 296-300
    • Joensen, J.B.1    Juul, S.2    Abrahamsen, J.3    Henneberg, E.W.4    Lindholt, J.S.5
  • 9
    • 44849118331 scopus 로고    scopus 로고
    • Assessing ankle-brachial index (ABI) by using automated oscillometric devices
    • Kawamura T. Assessing ankle-brachial index (ABI) by using automated oscillometric devices. Arq Br Cardio 90 (2008) 294-298
    • (2008) Arq Br Cardio , vol.90 , pp. 294-298
    • Kawamura, T.1
  • 10
    • 56749175036 scopus 로고    scopus 로고
    • Are automated blood pressure monitors accurate enough to calculate the ankle brachial pressure index?
    • MacDonald E., Froggatt P., Lawrence G., and Blair S. Are automated blood pressure monitors accurate enough to calculate the ankle brachial pressure index?. J Clin Moni Comp 22 (2008) 381-384
    • (2008) J Clin Moni Comp , vol.22 , pp. 381-384
    • MacDonald, E.1    Froggatt, P.2    Lawrence, G.3    Blair, S.4
  • 12
    • 54249128763 scopus 로고    scopus 로고
    • Oscillometric blood pressure measurement: a simple method in screening for peripheral arterial disease
    • Mehlsen J., Wiinberg N., and Bruce C. Oscillometric blood pressure measurement: a simple method in screening for peripheral arterial disease. Clin Physio Funct Imag 28 (2008) 426-429
    • (2008) Clin Physio Funct Imag , vol.28 , pp. 426-429
    • Mehlsen, J.1    Wiinberg, N.2    Bruce, C.3
  • 13
    • 0037366488 scopus 로고    scopus 로고
    • Comparison of ankle-brachial pressure index measurements using an automated oscillometric device with the standard doppler ultrasound technique
    • Ramanathan A., Conaghan P.J., Jenkinson A.D., and Bishop C.R. Comparison of ankle-brachial pressure index measurements using an automated oscillometric device with the standard doppler ultrasound technique. ANZ J Surg 73 (2003) 105-108
    • (2003) ANZ J Surg , vol.73 , pp. 105-108
    • Ramanathan, A.1    Conaghan, P.J.2    Jenkinson, A.D.3    Bishop, C.R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.