Volumn 59, Issue 3, 2008, Pages 296-300
|
Doppler ultrasound compared with strain gauge for measurement of systolic ankle blood pressure
c
Viborg Hosptial
*
(Denmark)
|
Author keywords
Ankle blood pressure; Doppler ultrasound; Strain gauge
|
Indexed keywords
ADULT;
AGED;
ANKLE BRACHIAL INDEX;
ARTICLE;
CONTROLLED STUDY;
DIAGNOSTIC TEST;
DOPPLER FLOWMETRY;
FEMALE;
HUMAN;
INTERMETHOD COMPARISON;
LEG ARTERY;
MAJOR CLINICAL STUDY;
MALE;
STRAIN GAUGE TRANSDUCER;
SYSTOLIC BLOOD PRESSURE;
TIBIAL ARTERY;
AGED;
AGED, 80 AND OVER;
ANKLE;
BLOOD PRESSURE;
BLOOD PRESSURE DETERMINATION;
FEMALE;
HUMANS;
MALE;
MIDDLE AGED;
PLETHYSMOGRAPHY;
PREDICTIVE VALUE OF TESTS;
REPRODUCIBILITY OF RESULTS;
SYSTOLE;
ULTRASONOGRAPHY, DOPPLER;
|
EID: 44849105111
PISSN: 00033197
EISSN: None
Source Type: Journal
DOI: 10.1177/0003319707308198 Document Type: Article |
Times cited : (14)
|