Volumn 35, Issue 4, 2009, Pages 210-220

Digital multiband receiver for magnetic resonance

Author keywords

Digital direct conversion; Direct sampling; Magnetic field monitoring; Multiband; NMR receiver

Indexed keywords


EID: 70449568813     PISSN: 15525031     EISSN: 1552504X     Source Type: Journal    
DOI: 10.1002/cmr.b.20149     Document Type: Article
Times cited : (5)

References (31)
  • 2
    • 0034845169 scopus 로고    scopus 로고
    • A generalized approach to parallel magnetic resonance imaging
    • Sodickson DK, McKenzie CA. 2001. A generalized approach to parallel magnetic resonance imaging. Med Phys 28:1629-1643.
    • (2001) Med Phys , vol.28 , pp. 1629-1643
    • Sodickson, D.K.1    McKenzie, C.A.2
  • 10
    • 70449612684 scopus 로고    scopus 로고
    • MRI system with dynamic receiver gain, U.S. Patent 5,451,876,1995
    • MRI system with dynamic receiver gain, U.S. Patent 5,451,876,1995.
  • 11
    • 0017558676 scopus 로고
    • The Shannon sampling theorem: Its various extensions and applications: A tutorial review
    • Jerri AJ. 1977. The Shannon sampling theorem: its various extensions and applications: a tutorial review. Proc IEEE 65:1565-1596.
    • (1977) Proc IEEE , vol.65 , pp. 1565-1596
    • Jerri, A.J.1
  • 14
    • 0041839495 scopus 로고
    • Guidelines for the use of oversampling in protein NMR
    • Beckman RA, Zuiderweg ERP. 1995. Guidelines for the use of oversampling in protein NMR. J Magn Reson A 113:223-231.
    • (1995) J Magn Reson A , vol.113 , pp. 223-231
    • Beckman, R.A.1    Zuiderweg, E.R.P.2
  • 19
    • 0015723180 scopus 로고
    • A computer program for designing optimum FIR linear phase digital filters
    • McClellan JH, Parks T, Rabiner L. 1973. A computer program for designing optimum FIR linear phase digital filters. IEEE Trans Audio Electroacoust 21:506-526.
    • (1973) IEEE Trans Audio Electroacoust , vol.21 , pp. 506-526
    • McClellan, J.H.1    Parks, T.2    Rabiner, L.3
  • 21
    • 0016588155 scopus 로고
    • Optimum FIR digital filter implementation for decimation, interpolation, and narrow-band filtering
    • Crochiere RE, Rabiner LR. 1975. Optimum FIR digital filter implementation for decimation, interpolation, and narrow-band filtering. IEEE Trans Acoust Speech Signal Process 23:444-456.
    • (1975) IEEE Trans Acoust Speech Signal Process , vol.23 , pp. 444-456
    • Crochiere, R.E.1    Rabiner, L.R.2
  • 22
    • 0021515633 scopus 로고
    • A class of linear-phase FIR filters for decimation, interpolation,and narrow-band filtering
    • Saramäki T. 1984. A class of linear-phase FIR filters for decimation, interpolation,and narrow-band filtering. IEEE Trans Acoust Speech Signal Process 32:1023-1036.
    • (1984) IEEE Trans Acoust Speech Signal Process , vol.32 , pp. 1023-1036
    • Saramäki, T.1
  • 24
    • 0033700459 scopus 로고    scopus 로고
    • Phase noise in oscillators: A unifying theory and numerical methods for characterization
    • Demir A, Mehrotra A, Roychowdhury J. 2000. Phase noise in oscillators: a unifying theory and numerical methods for characterization. IEEE Trans Circuits Syst I 47:655-674.
    • (2000) IEEE Trans Circuits Syst , vol.I47 , pp. 655-674
    • Demir, A.1    Mehrotra, A.2    Roychowdhury, J.3
  • 25
    • 68149172756 scopus 로고    scopus 로고
    • Trading of SNR and resolution in MR images
    • Kale SC, Chen XJ, Henkelmana RM. 2008. Trading of SNR and resolution in MR images. NMR Biomed 22(5):488-494.
    • (2008) NMR Biomed , vol.22 , Issue.5 , pp. 488-494
    • Kale, S.C.1    Chen, X.J.2    Henkelmana, R.M.3
  • 26
    • 0026601923 scopus 로고
    • Image reconstruction for echo planar imaging with nonequidistant k-space sampling
    • Bruder H, Fischer H, Reinfelder H.-E, Schmitt F. 1992. Image reconstruction for echo planar imaging with nonequidistant k-space sampling. Magn Reson Med 23:201-398.
    • (1992) Magn Reson Med , vol.23 , pp. 201-398
    • Bruder, H.1    Fischer, H.2    Reinfelder, H.-E.3    Schmitt, F.4
  • 27
    • 70449620428 scopus 로고    scopus 로고
    • Towards routine field monitoring for MRI: A transmit/receive system based on shielded NMR probes
    • Toronto, Ontario
    • Barmet C, De Zanche N, Wilm B, Pruessmann KP. 2008. Towards routine field monitoring for MRI: a transmit/receive system based on shielded NMR probes. Proc ISMRM, Toronto, Ontario, 16:1152.
    • (2008) Proc ISMRM , vol.16 , pp. 1152
    • Barmet, C.1    de Zanche, N.2    Wilm, B.3    Pruessmann, K.P.4
  • 28
    • 70449599903 scopus 로고    scopus 로고
    • Magnetic field monitoring addon toolkit based on transmit-receive NMR probes
    • Toronto, Ontario
    • Sipilä P, Lechner S, Lange D, Greding S, Wachutka G, Wiesinger F. 2008. Magnetic field monitoring addon toolkit based on transmit-receive NMR probes. Proc ISMRM, Toronto, Ontario, 16:680.
    • (2008) Proc ISMRM , vol.16 , pp. 680
    • Sipilä, P.1    Lechner, S.2    Lange, D.3    Greding, S.4    Wachutka, G.5    Wiesinger, F.6
  • 29
    • 70449616075 scopus 로고    scopus 로고
    • Susceptibility-matched H2O NMR probes for magnetic field monitoring
    • Honolulu, Hawaii
    • Sipilä P, Greding S, Wachutka G, Wiesinger F. 2009. Susceptibility-matched H2O NMR probes for magnetic field monitoring. Proc ISMRM, Honolulu, Hawaii, 17:3076.
    • (2009) Proc ISMRM , vol.17 , pp. 3076
    • Sipilä, P.1    Greding, S.2    Wachutka, G.3    Wiesinger, F.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.