메뉴 건너뛰기




Volumn 14, Issue 10, 2009, Pages

Measurement of dental implant stability by resonance frequency analysis: A review of the literature

Author keywords

Dental implants; Resonance frequency analysis; Stability

Indexed keywords

BONE REGENERATION; BONE REMODELING; CLINICAL ASSESSMENT; CLINICAL RESEARCH; CONTROLLED STUDY; DATA BASE; HISTOLOGY; HUMAN; IMAGING SYSTEM; INFORMATION RETRIEVAL; MECHANICAL STRESS; MEDICAL LITERATURE; NON INVASIVE PROCEDURE; OUTCOME ASSESSMENT; PROSTHESIS; RESONANCE FREQUENCY ANALYSIS; REVIEW; TOOTH IMPLANTATION;

EID: 70449470929     PISSN: 16984447     EISSN: 16986946     Source Type: Journal    
DOI: 10.4317/medoral.14.e538     Document Type: Review
Times cited : (58)

References (41)
  • 1
    • 0003919966 scopus 로고
    • Branemark P-I, Zarb GA, Albrektsson T (eds.) Chicago:Quintessence
    • Branemark P-I, Zarb GA, Albrektsson T (eds.) Tissue- Integrated Prostheses. Chicago:Quintessence; 1985.
    • (1985) Tissue- Integrated Prostheses
  • 2
    • 0019414459 scopus 로고
    • The reactions of bone, connective tissue, and epithelium to endosteal implants with titanium-sprayed surfaces
    • Schroeder A, Van der Zypen E, Stich H, Sutter F. The reactions of bone, connective tissue, and epithelium to endosteal implants with titanium-sprayed surfaces. J Maxillofac Surg. 1981;9:15-25. (Pubitemid 11056710)
    • (1981) Journal of Maxillofacial Surgery , vol.9 , Issue.1 , pp. 15-25
    • Schroeder, A.1    Van Der Zypen, E.2    Stich, H.3    Sutter, F.4
  • 3
    • 0032151752 scopus 로고    scopus 로고
    • Assessment of Implant Stability as a Prognostic Determinant
    • Meredith N. Assessment of implant stability as a prognostic determinant. Int J Prosthodont. 1998;11:491-501. (Pubitemid 128513406)
    • (1998) International Journal of Prosthodontics , vol.11 , Issue.5 , pp. 491-501
    • Meredith, N.1
  • 5
    • 0029439911 scopus 로고
    • Accuracy and precision in the radiographic diagnosis of clinical instability in Brånemark dental implants
    • Sundén S, Gröndahl K, Gröndahl HG. Accuracy and precision in the radiographic diagnosis of clinical instability in Brånemark dental implants. Clin Oral Implants Res. 1995;6:220-226
    • (1995) Clin Oral Implants Res , vol.6 , pp. 220-226
    • Sundén, S.1    Gröndahl, K.2    Gröndahl, H.G.3
  • 6
    • 0032059195 scopus 로고    scopus 로고
    • Relationship between Contact Time Measurements and PTV Values When Using the Periotest to Measure Implant Stability
    • Meredith N, Friberg B, Sennerby L, Aparicio C. Relationship between contact time measurements and PTV values when using the Periotest to measure implant stability. Int J Prosthodont. 1998;11:269-275 (Pubitemid 128505811)
    • (1998) International Journal of Prosthodontics , vol.11 , Issue.3 , pp. 269-275
    • Meredith, N.1    Friberg, B.2    Sennerby, L.3    Aparicio, C.4
  • 7
    • 0030224153 scopus 로고    scopus 로고
    • Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis
    • Meredith N, Alleyne D, Cawley P. Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis. Clin Oral Implants Res. 1996;7:261-267 (Pubitemid 126670532)
    • (1996) Clinical Oral Implants Research , vol.7 , Issue.3 , pp. 261-267
    • Meredith, N.1    Alleyne, D.2    Cawley, P.3
  • 9
    • 0032458301 scopus 로고    scopus 로고
    • A Review of Nondestructive Test Methods and Their Application to Measure the Stability and Osseointegration of Bone Anchored Endosseous Implants
    • Meredith N. A review of nondestructive test methods and their application to measure the stability and osseointegration of bone anchored endosseous implants. Crit Rev Biomed Eng. 1998;26:275-291 (Pubitemid 128418540)
    • (1998) Critical Reviews in Biomedical Engineering , vol.26 , Issue.4 , pp. 275-291
    • Meredith, N.1
  • 10
    • 12244296400 scopus 로고    scopus 로고
    • Diagnostic parameters for monitoring peri-implant conditions
    • Salvi GE, Lang NP. Diagnostic parameters for monitoring peri-implant conditions. Int J Oral Maxillofac Implants. 2004;19 Suppl:116-127
    • (2004) Int J Oral Maxillofac Implants , vol.19 , Issue.SUPPL. , pp. 116-127
    • Salvi, G.E.1    Lang, N.P.2
  • 12
    • 0032061729 scopus 로고    scopus 로고
    • Resonance frequency analysis: Measuring implant stability and osseointegration
    • 500-502
    • Sennerby L, Meredith N. Resonance frequency analysis: measuring implant stability and osseointegration. Compend Contin Educ Dent. 1998;19:493-8, 500-502.
    • (1998) Compend Contin Educ Dent , vol.19 , pp. 493-498
    • Sennerby, L.1    Meredith, N.2
  • 13
    • 0036481346 scopus 로고    scopus 로고
    • Resonance frequency assessment of dental implant stability with various bone qualities: A numerical approach
    • Huang HM, Lee SY, Yeh CY, Lin CT. Resonance frequency assessment of dental implant stability with various bone qualities: a numerical approach. Clin Oral Implants Res. 2002;13:65-74.
    • (2002) Clin Oral Implants Res , vol.13 , pp. 65-74
    • Huang, H.M.1    Lee, S.Y.2    Yeh, C.Y.3    Lin, C.T.4
  • 14
    • 0033176199 scopus 로고    scopus 로고
    • A comparison between cutting torque and resonance frequency measurements of maxillary implants. A 20-month clinical study
    • Friberg B, Sennerby L, Meredith N, Lekholm U. A comparison between cutting torque and resonance frequency measurements of maxillary implants. A 20-month clinical study. Int J Oral Maxillofac Surg. 1999;28:297-303.
    • (1999) Int J Oral Maxillofac Surg , vol.28 , pp. 297-303
    • Friberg, B.1    Sennerby, L.2    Meredith, N.3    Lekholm, U.4
  • 16
    • 0034574211 scopus 로고    scopus 로고
    • Measurements comparing the initial stability of five designs of dental implants: A human cadaver study
    • O'Sullivan D, Sennerby L, Meredith N. Measurements comparing the initial stability of five designs of dental implants: a human cadaver study. Clin Implant Dent Relat Res. 2000;2:85-92.
    • (2000) Clin Implant Dent Relat Res , vol.2 , pp. 85-92
    • O'Sullivan, D.1    Sennerby, L.2    Meredith, N.3
  • 18
    • 4644230057 scopus 로고    scopus 로고
    • Resonance frequency analysis of implants subjected to immediate or early functional occlusal loading. Successful vs. failing implants
    • Glauser R, Sennerby L, Meredith N, Rée A, Lundgren A, Gottlow J, et al. Resonance frequency analysis of implants subjected to immediate or early functional occlusal loading. Successful vs. failing implants. Clin Oral Implants Res. 2004;15:428-434
    • (2004) Clin Oral Implants Res , vol.15 , pp. 428-434
    • Glauser, R.1    Sennerby, L.2    Meredith, N.3    Rée, A.4    Lundgren, A.5    Gottlow, J.6
  • 19
    • 0041511713 scopus 로고    scopus 로고
    • Early loading of maxillary fixed cross-arch dental prostheses supported by six or eight oxidized titanium implants: Results after 1 year of loading, case series
    • Olsson M, Urde G, Andersen JB, Sennerby L. Early loading of maxillary fixed cross-arch dental prostheses supported by six or eight oxidized titanium implants: results after 1 year of loading, case series. Clin Implant Dent Relat Res. 2003;5 Suppl 1:81-87
    • (2003) Clin Implant Dent Relat Res , vol.5 , Issue.SUPPL. 1 , pp. 81-87
    • Olsson, M.1    Urde, G.2    Andersen, J.B.3    Sennerby, L.4
  • 21
    • 0033169238 scopus 로고    scopus 로고
    • Stability measurements of one-stage Brånemark implants during healing in mandibles. A clinical resonance frequency analysis study
    • Friberg B, Sennerby L, Linden B, Gröndahl K, Lekholm U. Stability measurements of one-stage Brånemark implants during healing in mandibles. A clinical resonance frequency analysis study. Int J Oral Maxillofac Surg. 1999;28:266-272
    • (1999) Int J Oral Maxillofac Surg , vol.28 , pp. 266-272
    • Friberg, B.1    Sennerby, L.2    Linden, B.3    Gröndahl, K.4    Lekholm, U.5
  • 22
    • 0031152189 scopus 로고    scopus 로고
    • The application of resonance frequency measurements to study the stability of titanium implants during healing in the rabbit tibia
    • Meredith N, Shagaldi F, Alleyne D, Sennerby L, Cawley P. The application of resonance frequency measurements to study the stability of titanium implants during healing in the rabbit tibia. Clin Oral Implants Res. 1997;8:234-243 (Pubitemid 127688459)
    • (1997) Clinical Oral Implants Research , vol.8 , Issue.3 , pp. 234-243
    • Meredith, N.1    Shagaldi, F.2    Alleyne, D.3    Sennerby, L.4    Cawley, P.5
  • 23
    • 0036987398 scopus 로고    scopus 로고
    • Stability measurements of osseointegrated implants using Osstell in partially edentulous jaws after 1 year of loading: A pilot study
    • Balleri P, Cozzolino A, Ghelli L, Momicchioli G, Varriale A. Stability measurements of osseointegrated implants using Osstell in partially edentulous jaws after 1 year of loading: a pilot study. Clin Implant Dent Relat Res. 2002;4:128-132
    • (2002) Clin Implant Dent Relat Res , vol.4 , pp. 128-132
    • Balleri, P.1    Cozzolino, A.2    Ghelli, L.3    Momicchioli, G.4    Varriale, A.5
  • 24
    • 34248226924 scopus 로고    scopus 로고
    • Augmentation of the posterior atrophic edentulous maxilla with implants placed in the ulna: A prospective single-blind controlled clinical trial
    • Cannizzaro G, Leone M, Consolo U, Ferri V, Licitra G, Worthington H, et al. Augmentation of the posterior atrophic edentulous maxilla with implants placed in the ulna: a prospective single-blind controlled clinical trial. Int J Oral Maxillofac Implants. 2007;22:280-288
    • (2007) Int J Oral Maxillofac Implants , vol.22 , pp. 280-288
    • Cannizzaro, G.1    Leone, M.2    Consolo, U.3    Ferri, V.4    Licitra, G.5    Worthington, H.6
  • 25
    • 34248141232 scopus 로고    scopus 로고
    • Resonance frequency analysis assessment of implant stability in labial onlay grafted posterior mandibles: A pilot clinical study
    • Ozkan Y, Ozcan M, Varol A, Akoglu B, Ucankale M, Basa S. Resonance frequency analysis assessment of implant stability in labial onlay grafted posterior mandibles: a pilot clinical study. Int J Oral Maxillofac Implants. 2007;22:235-242
    • (2007) Int J Oral Maxillofac Implants , vol.22 , pp. 235-242
    • Ozkan, Y.1    Ozcan, M.2    Varol, A.3    Akoglu, B.4    Ucankale, M.5    Basa, S.6
  • 26
    • 34548563340 scopus 로고    scopus 로고
    • Identification of stability changes for immediately placed dental implants
    • West JD, Oates TW. Identification of stability changes for immediately placed dental implants. Int J Oral Maxillofac Implants. 2007;22:623-630
    • (2007) Int J Oral Maxillofac Implants , vol.22 , pp. 623-630
    • West, J.D.1    Oates, T.W.2
  • 27
    • 33847625813 scopus 로고    scopus 로고
    • Immediate implant placement with transmucosal healing in areas of aesthetic priority. A multicentre randomized-controlled clinical trial I. Surgical outcomes
    • Lang NP, Tonetti MS, Suvan JE, Pierre Bernard J, Botticelli D, Fourmousis I, et al. Immediate implant placement with transmucosal healing in areas of aesthetic priority. A multicentre randomized-controlled clinical trial I. Surgical outcomes. Clin Oral Implants Res. 2007;18:188-196
    • (2007) Clin Oral Implants Res , vol.18 , pp. 188-196
    • Lang, N.P.1    Tonetti, M.S.2    Suvan, J.E.3    Pierre Bernard, J.4    Botticelli, D.5    Fourmousis, I.6
  • 28
    • 33947222756 scopus 로고    scopus 로고
    • Immediate functional loading of implants placed with flapless surgery in the edentulous maxilla: 1-year follow-up of a single cohort study
    • Cannizzaro G, Leone M, Esposito M. Immediate functional loading of implants placed with flapless surgery in the edentulous maxilla: 1-year follow-up of a single cohort study. Int J Oral Maxillofac Implants. 2007;22:87-95.
    • (2007) Int J Oral Maxillofac Implants , vol.22 , pp. 87-95
    • Cannizzaro, G.1    Leone, M.2    Esposito, M.3
  • 30
    • 34547217298 scopus 로고    scopus 로고
    • Resonance frequency analysis in relation to jawbone characteristics and during early healing of implant installation
    • Huwiler MA, Pjetursson BE, Bosshardt DD, Salvi GE, Lang NP. Resonance frequency analysis in relation to jawbone characteristics and during early healing of implant installation. Clin Oral Implants Res. 2007;18:275-280
    • (2007) Clin Oral Implants Res , vol.18 , pp. 275-280
    • Huwiler, M.A.1    Pjetursson, B.E.2    Bosshardt, D.D.3    Salvi, G.E.4    Lang, N.P.5
  • 31
    • 37249055018 scopus 로고    scopus 로고
    • Relevance of resonance frequency analysis to evaluate dental implant stability: Simulation and histomorphometrical animal experiments
    • Ito Y, Sato D, Yoneda S, Ito D, Kondo H, Kasugai S. Relevance of resonance frequency analysis to evaluate dental implant stability: simulation and histomorphometrical animal experiments. Clin Oral Implants Res. 2008;19:9-14.
    • (2008) Clin Oral Implants Res , vol.19 , pp. 9-14
    • Ito, Y.1    Sato, D.2    Yoneda, S.3    Ito, D.4    Kondo, H.5    Kasugai, S.6
  • 32
    • 37249059880 scopus 로고    scopus 로고
    • Comparative histomorphometry and resonance frequency analysis of implants with moderately rough surfaces in a loaded animal model
    • Al-Nawas B, Groetz KA, Goetz H, Duschner H, Wagner W. Comparative histomorphometry and resonance frequency analysis of implants with moderately rough surfaces in a loaded animal model. Clin Oral Implants Res. 2008;19:1-8.
    • (2008) Clin Oral Implants Res , vol.19 , pp. 1-8
    • Al-Nawas, B.1    Groetz, K.A.2    Goetz, H.3    Duschner, H.4    Wagner, W.5
  • 33
    • 37849013565 scopus 로고    scopus 로고
    • Parameters of resonance frequency measurement values: A retrospective study of 385 ITI dental implants
    • Karl M, Graef F, Heckmann S, Krafft T. Parameters of resonance frequency measurement values: a retrospective study of 385 ITI dental implants. Clin Oral Implants Res. 2008;19:214-218
    • (2008) Clin Oral Implants Res , vol.19 , pp. 214-218
    • Karl, M.1    Graef, F.2    Heckmann, S.3    Krafft, T.4
  • 34
    • 37849016192 scopus 로고    scopus 로고
    • Implant stability during osseointegration in irradiated and non-irradiated minipig alveolar bone: An experimental study
    • Verdonck HW, Meijer GJ, Laurin T, Nieman FH, Stoll C, Riediger D, et al. Implant stability during osseointegration in irradiated and non-irradiated minipig alveolar bone: an experimental study. Clin Oral Implants Res. 2008;19:201-206
    • (2008) Clin Oral Implants Res , vol.19 , pp. 201-206
    • Verdonck, H.W.1    Meijer, G.J.2    Laurin, T.3    Nieman, F.H.4    Stoll, C.5    Riediger, D.6
  • 35
    • 0036618288 scopus 로고    scopus 로고
    • Resonance frequency and removal torque analysis of implants with turned and anodized surface oxides
    • DOI 10.1034/j.1600-0501.2002.130304.x
    • Sul YT, Johansson CB, Jeong Y, Wennerberg A, Albrektsson T. Resonance frequency and removal torque analysis of implants with turned and anodized surface oxides. Clin Oral Implants Res. 2002;13:252-259 (Pubitemid 41698462)
    • (2002) Clinical Oral Implants Research , vol.13 , Issue.3 , pp. 252-259
    • Sul, Y.-T.1    Johansson, C.B.2    Jeong, Y.3    Wennerberg, A.4    Albrektsson, T.5
  • 36
    • 0033177543 scopus 로고    scopus 로고
    • Effects of barrier membranes on bone resorption and implant stability in onlay bone grafts. An experimental study
    • Rasmusson L, Meredith N, Kahnberg KE, Sennerby L. Effects of barrier membranes on bone resorption and implant stability in onlay bone grafts. An experimental study. Clin Oral Implants Res. 1999;10:267-277
    • (1999) Clin Oral Implants Res , vol.10 , pp. 267-277
    • Rasmusson, L.1    Meredith, N.2    Kahnberg, K.E.3    Sennerby, L.4
  • 37
    • 0043014563 scopus 로고    scopus 로고
    • Histology of retrieved immediately and early loaded oxidized implants: Light microscopic observations after 5 to 9 months of loading in the posterior mandible
    • Rocci A, Martignoni M, Burgos PM, Gottlow J, Sennerby L. Histology of retrieved immediately and early loaded oxidized implants: light microscopic observations after 5 to 9 months of loading in the posterior mandible. Clin Implant Dent Relat Res. 2003;5 Suppl 1:88-98.
    • (2003) Clin Implant Dent Relat Res , vol.5 , Issue.SUPPL. 1 , pp. 88-98
    • Rocci, A.1    Martignoni, M.2    Burgos, P.M.3    Gottlow, J.4    Sennerby, L.5
  • 38
    • 0042012797 scopus 로고    scopus 로고
    • Immediate occlusal loading of single lower molars using Brånemark System Wide-Platform TiUnite implants: An interim report of a prospective open-ended clinical multicenter study
    • Calandriello R, Tomatis M, Vallone R, Rangert B, Gottlow J. Immediate occlusal loading of single lower molars using Brånemark System Wide-Platform TiUnite implants: an interim report of a prospective open-ended clinical multicenter study. Clin Implant Dent Relat Res. 2003;5 Suppl 1:74-80.
    • (2003) Clin Implant Dent Relat Res , vol.5 , Issue.SUPPL. 1 , pp. 74-80
    • Calandriello, R.1    Tomatis, M.2    Vallone, R.3    Rangert, B.4    Gottlow, J.5
  • 40
    • 0345304947 scopus 로고    scopus 로고
    • Implant stability and histomorphometry: A correlation study in human cadavers using stepped cylinder implants
    • DOI 10.1034/j.1600-0501.2003.00937.x
    • Nkenke E, Hahn M, Weinzierl K, Radespiel-Tröger M, Neukam FW, Engelke K. Implant stability and histomorphometry: a correlation study in human cadavers using stepped cylinder implants. Clin Oral Implants Res. 2003;14:601-609 (Pubitemid 37463770)
    • (2003) Clinical Oral Implants Research , vol.14 , Issue.5 , pp. 601-609
    • Nkenke, E.1    Hahn, M.2    Weinzierl, K.3    Radespiel-Troger, M.4    Neukam, F.W.5    Engelke, K.6
  • 41
    • 20744446862 scopus 로고    scopus 로고
    • Immediate occlusal loading of Brånemark System TiUnite implants placed predominantly in soft bone: 4-year results of a prospective clinical study
    • Glauser R, Ruhstaller P, Windisch S, Zembic A, Lundgren A, Gottlow J, et al. Immediate occlusal loading of Brånemark System TiUnite implants placed predominantly in soft bone: 4-year results of a prospective clinical study. Clin Implant Dent Relat Res. 2005;7 Suppl 1:S52-9.
    • (2005) Clin Implant Dent Relat Res , vol.7 , Issue.SUPPL. 1
    • Glauser, R.1    Ruhstaller, P.2    Windisch, S.3    Zembic, A.4    Lundgren, A.5    Gottlow, J.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.