메뉴 건너뛰기




Volumn 62, Issue 5, 2009, Pages 1261-1269

Partial fourier reconstruction through data fitting and convolution in k-space

Author keywords

Convolution; Data fitting; Fast imaging; Partial fourier; Reconstruction

Indexed keywords

CONVOLUTION; DATA HANDLING; ERRORS; FOURIER TRANSFORMS; IMAGE ENHANCEMENT; IMAGE RECONSTRUCTION; SET THEORY; SIGNAL RECEIVERS;

EID: 70449382073     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.22128     Document Type: Article
Times cited : (32)

References (17)
  • 1
    • 0034952064 scopus 로고    scopus 로고
    • High-resolution fMRI using multislice partial k-space GR-EPI with cubic voxels
    • DOI 10.1002/mrm.1166
    • Hyde JS, Biswal BB, Jesmanowicz A. High-resolution fMRI using multislice partial k-space GR-EPI with cubic voxels. Magn Reson Med 2001;46:114-125. (Pubitemid 32592144)
    • (2001) Magnetic Resonance in Medicine , vol.46 , Issue.1 , pp. 114-125
    • Hyde, J.S.1    Biswal, B.B.2    Jesmanowicz, A.3
  • 2
    • 0345600048 scopus 로고    scopus 로고
    • Multishot Partial-k-Space EPI for High-Resolution fMRI Demonstrated in a Rat Whisker Barrel Stimulation Model at 3T
    • DOI 10.1002/mrm.10655
    • Lu H, Mazaheri Y, Zhang R, Jesmanowicz A, Hyde JS. Multishot partialk- space EPI for high-resolution fMRI demonstrated in a rat whisker barrel stimulation model at 3T. Magn Reson Med 2003;50:1215-1222. (Pubitemid 37494022)
    • (2003) Magnetic Resonance in Medicine , vol.50 , Issue.6 , pp. 1215-1222
    • Lu, H.1    Mazaheri, Y.2    Zhang, R.3    Jesmanowicz, A.4    Hyde, J.S.5
  • 3
    • 0031759093 scopus 로고    scopus 로고
    • Single-shot half k-space high-resolution gradient-recalled EPI for fMRI at 3 Tesla
    • DOI 10.1002/mrm.1910400517
    • Jesmanowicz A, Bandettini PA, Hyde JS. Single-shot half k-space high resolution gradient recalled EPI for fMRI at 3 tesla. Magn Reson Med 1998;40:754-762. (Pubitemid 28493655)
    • (1998) Magnetic Resonance in Medicine , vol.40 , Issue.5 , pp. 754-762
    • Jesmanowicz, A.1    Bandettini, P.A.2    Hyde, J.S.3
  • 4
    • 41849136878 scopus 로고    scopus 로고
    • Improved image reconstruction for partial Fourier gradient-echo echo-planar imaging (EPI)
    • Chen N-K, Oshio K, Panych LP. Improved image reconstruction for partial Fourier gradient-echo echo-planar imaging (EPI). Magn Reson Med 2008;59:916-924.
    • (2008) Magn Reson Med , vol.59 , pp. 916-924
    • Chen, N.-K.1    Oshio, K.2    Panych, L.P.3
  • 5
    • 0034764216 scopus 로고    scopus 로고
    • New strategy for reconstructing partial-fourier imaging data in functional MRI
    • DOI 10.1002/mrm.1296
    • Zhang X, Yacoub E, Hu X. New strategy for reconstructing partial- Fourier imaging data in functional MRI. Magn Reson Med 2001;46: 1045-1048. (Pubitemid 33019934)
    • (2001) Magnetic Resonance in Medicine , vol.46 , Issue.5 , pp. 1045-1048
    • Zhang, X.1    Yacoub, E.2    Hu, X.3
  • 9
    • 0027216325 scopus 로고
    • Quantitative evaluation of several partial Fourier reconstruction algorithms used in MRI
    • McGibney G, Smith MR, Nichols ST, Crawley A. Quantitative evaluation of several partial Fourier reconstruction algorithms used in MRI. Magn Reson Med 1993;30:51-59. (Pubitemid 23203796)
    • (1993) Magnetic Resonance in Medicine , vol.30 , Issue.1 , pp. 51-59
    • McGibney, G.1    Smith, M.R.2    Nichols, S.T.3    Crawley, A.4
  • 10
    • 0001031295 scopus 로고
    • A fast, iterative, partial-Fourier technique capable of local phase recovery
    • Haacke EM, Lindskog ED, Lin W. A fast, iterative, partial-Fourier technique capable of local phase recovery. J Magn Reson 1991;92:126-145.
    • (1991) J Magn Reson , vol.92 , pp. 126-145
    • Haacke, E.M.1    Lindskog, E.D.2    Lin, W.3
  • 11
    • 0001423478 scopus 로고
    • Reducing MR imaging time by one-sided reconstruction
    • Cuppen J, van Est A. Reducing MR imaging time by one-sided reconstruction. Magn Reson Imaging 1987;5:526-527.
    • (1987) Magn Reson Imaging , vol.5 , pp. 526-527
    • Cuppen, J.1    Van Est, A.2
  • 15
    • 40449129412 scopus 로고    scopus 로고
    • High-pass GRAPPA: An image support reduction technique for improved partially parallel imaging
    • DOI 10.1002/mrm.21495
    • Huang F, Li Y, Vijayakumar S, Hertel S, Duensing GR. High pass GRAPPA (hp-GRAPPA): an image support reduction technique for improved PPI. Magn Reson Med 2008;59:642-649. (Pubitemid 351348237)
    • (2008) Magnetic Resonance in Medicine , vol.59 , Issue.3 , pp. 642-649
    • Huang, F.1    Li, Y.2    Vijayakumar, S.3    Hertel, S.4    Duensing, G.R.5
  • 16
    • 37549029839 scopus 로고    scopus 로고
    • On optimality of parallel MRI reconstruction in k-space
    • Samsonov AA. On optimality of parallel MRI reconstruction in k-space. Magn Reson Med 2008;59:156-164.
    • (2008) Magn Reson Med , vol.59 , pp. 156-164
    • Samsonov, A.A.1
  • 17
    • 41849127475 scopus 로고    scopus 로고
    • Cross-validation-based kernel support selection for improved GRAPPA reconstruction
    • Nana R, Zhao T, Heberlein K, LaConte SM, Hu X. Cross-validation-based kernel support selection for improved GRAPPA reconstruction. Magn Reson Med 2008;59:819-825.
    • (2008) Magn Reson Med , vol.59 , pp. 819-825
    • Nana, R.1    Zhao, T.2    Heberlein, K.3    LaConte, S.M.4    Hu, X.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.