1
-
-
0034952064
-
High-resolution fMRI using multislice partial k-space GR-EPI with cubic voxels
-
DOI 10.1002/mrm.1166
-
Hyde JS, Biswal BB, Jesmanowicz A. High-resolution fMRI using multislice partial k-space GR-EPI with cubic voxels. Magn Reson Med 2001;46:114-125. (Pubitemid 32592144)
-
(2001)
Magnetic Resonance in Medicine
, vol.46
, Issue.1
, pp. 114-125
-
-
Hyde, J.S.1
Biswal, B.B.2
Jesmanowicz, A.3
-
2
-
-
0345600048
-
Multishot Partial-k-Space EPI for High-Resolution fMRI Demonstrated in a Rat Whisker Barrel Stimulation Model at 3T
-
DOI 10.1002/mrm.10655
-
Lu H, Mazaheri Y, Zhang R, Jesmanowicz A, Hyde JS. Multishot partialk- space EPI for high-resolution fMRI demonstrated in a rat whisker barrel stimulation model at 3T. Magn Reson Med 2003;50:1215-1222. (Pubitemid 37494022)
-
(2003)
Magnetic Resonance in Medicine
, vol.50
, Issue.6
, pp. 1215-1222
-
-
Lu, H.1
Mazaheri, Y.2
Zhang, R.3
Jesmanowicz, A.4
Hyde, J.S.5
-
3
-
-
0031759093
-
Single-shot half k-space high-resolution gradient-recalled EPI for fMRI at 3 Tesla
-
DOI 10.1002/mrm.1910400517
-
Jesmanowicz A, Bandettini PA, Hyde JS. Single-shot half k-space high resolution gradient recalled EPI for fMRI at 3 tesla. Magn Reson Med 1998;40:754-762. (Pubitemid 28493655)
-
(1998)
Magnetic Resonance in Medicine
, vol.40
, Issue.5
, pp. 754-762
-
-
Jesmanowicz, A.1
Bandettini, P.A.2
Hyde, J.S.3
-
4
-
-
41849136878
-
Improved image reconstruction for partial Fourier gradient-echo echo-planar imaging (EPI)
-
Chen N-K, Oshio K, Panych LP. Improved image reconstruction for partial Fourier gradient-echo echo-planar imaging (EPI). Magn Reson Med 2008;59:916-924.
-
(2008)
Magn Reson Med
, vol.59
, pp. 916-924
-
-
Chen, N.-K.1
Oshio, K.2
Panych, L.P.3
-
5
-
-
0034764216
-
New strategy for reconstructing partial-fourier imaging data in functional MRI
-
DOI 10.1002/mrm.1296
-
Zhang X, Yacoub E, Hu X. New strategy for reconstructing partial- Fourier imaging data in functional MRI. Magn Reson Med 2001;46: 1045-1048. (Pubitemid 33019934)
-
(2001)
Magnetic Resonance in Medicine
, vol.46
, Issue.5
, pp. 1045-1048
-
-
Zhang, X.1
Yacoub, E.2
Hu, X.3
-
6
-
-
23244468400
-
Homodyne reconstruction and IDEAL water-fat decomposition
-
DOI 10.1002/mrm.20586
-
Reeder SB, Hargreaves BA, Yu H, Brittain JH. Homodyne reconstruction and IDEAL water-fat decomposition. Magn Reson Med 2005;54: 586-593. (Pubitemid 41233753)
-
(2005)
Magnetic Resonance in Medicine
, vol.54
, Issue.3
, pp. 586-593
-
-
Reeder, S.B.1
Hargreaves, B.A.2
Yu, H.3
Brittain, J.H.4
-
9
-
-
0027216325
-
Quantitative evaluation of several partial Fourier reconstruction algorithms used in MRI
-
McGibney G, Smith MR, Nichols ST, Crawley A. Quantitative evaluation of several partial Fourier reconstruction algorithms used in MRI. Magn Reson Med 1993;30:51-59. (Pubitemid 23203796)
-
(1993)
Magnetic Resonance in Medicine
, vol.30
, Issue.1
, pp. 51-59
-
-
McGibney, G.1
Smith, M.R.2
Nichols, S.T.3
Crawley, A.4
-
10
-
-
0001031295
-
A fast, iterative, partial-Fourier technique capable of local phase recovery
-
Haacke EM, Lindskog ED, Lin W. A fast, iterative, partial-Fourier technique capable of local phase recovery. J Magn Reson 1991;92:126-145.
-
(1991)
J Magn Reson
, vol.92
, pp. 126-145
-
-
Haacke, E.M.1
Lindskog, E.D.2
Lin, W.3
-
11
-
-
0001423478
-
Reducing MR imaging time by one-sided reconstruction
-
Cuppen J, van Est A. Reducing MR imaging time by one-sided reconstruction. Magn Reson Imaging 1987;5:526-527.
-
(1987)
Magn Reson Imaging
, vol.5
, pp. 526-527
-
-
Cuppen, J.1
Van Est, A.2
-
12
-
-
0036263907
-
Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA)
-
DOI 10.1002/mrm.10171
-
Griswold MA, Jakob PM, Heidemann RM, Mathias Nittka, Jellus V, Wang J, Kiefer B, Haase A. Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med 2002;47:1202-1210. (Pubitemid 34587412)
-
(2002)
Magnetic Resonance in Medicine
, vol.47
, Issue.6
, pp. 1202-1210
-
-
Griswold, M.A.1
Jakob, P.M.2
Heidemann, R.M.3
Nittka, M.4
Jellus, V.5
Wang, J.6
Kiefer, B.7
Haase, A.8
-
13
-
-
0025226022
-
The NMR phased array
-
Roemer PB, Edelstein WA, Hayes CE, Souza SP, Mueller OM. The NMR phased array. Magn Reson Med 1990;16:192-225.
-
(1990)
Magn Reson Med
, vol.16
, pp. 192-225
-
-
Roemer, P.B.1
Edelstein, W.A.2
Hayes, C.E.3
Souza, S.P.4
Mueller, O.M.5
-
15
-
-
40449129412
-
High-pass GRAPPA: An image support reduction technique for improved partially parallel imaging
-
DOI 10.1002/mrm.21495
-
Huang F, Li Y, Vijayakumar S, Hertel S, Duensing GR. High pass GRAPPA (hp-GRAPPA): an image support reduction technique for improved PPI. Magn Reson Med 2008;59:642-649. (Pubitemid 351348237)
-
(2008)
Magnetic Resonance in Medicine
, vol.59
, Issue.3
, pp. 642-649
-
-
Huang, F.1
Li, Y.2
Vijayakumar, S.3
Hertel, S.4
Duensing, G.R.5
-
16
-
-
37549029839
-
On optimality of parallel MRI reconstruction in k-space
-
Samsonov AA. On optimality of parallel MRI reconstruction in k-space. Magn Reson Med 2008;59:156-164.
-
(2008)
Magn Reson Med
, vol.59
, pp. 156-164
-
-
Samsonov, A.A.1
-
17
-
-
41849127475
-
Cross-validation-based kernel support selection for improved GRAPPA reconstruction
-
Nana R, Zhao T, Heberlein K, LaConte SM, Hu X. Cross-validation-based kernel support selection for improved GRAPPA reconstruction. Magn Reson Med 2008;59:819-825.
-
(2008)
Magn Reson Med
, vol.59
, pp. 819-825
-
-
Nana, R.1
Zhao, T.2
Heberlein, K.3
LaConte, S.M.4
Hu, X.5
|