-
1
-
-
0031027274
-
Intracranial aneurysms
-
W.I. Schievink, "Intracranial aneurysms", N Engl J Med, vol. 336, no. 1, pp. 28-40, 1997.
-
(1997)
N Engl J Med
, vol.336
, Issue.1
, pp. 28-40
-
-
Schievink, W.I.1
-
2
-
-
17444424630
-
Efficient pipeline for image-based patient-specific analysis of cerebral aneurysm hemodynamics: Technique and sensitivity
-
J.R. Cebral, M.A. Castro, S. Appanaboyina, C.M. Putman, D. Millan, and A.F. Frangi, "Efficient pipeline for image-based patient-specific analysis of cerebral aneurysm hemodynamics: technique and sensitivity", IEEE Trans Med Imaging, vol. 24, no. 4, pp. 457-467, 2005.
-
(2005)
IEEE Trans Med Imaging
, vol.24
, Issue.4
, pp. 457-467
-
-
Cebral, J.R.1
Castro, M.A.2
Appanaboyina, S.3
Putman, C.M.4
Millan, D.5
Frangi, A.F.6
-
3
-
-
47149083067
-
Piv-measured versus cfd-predicted flow dynamics in anatomically realistic cerebral aneurysm models
-
M.D. Ford, H.N. Nikolov, J.S. Milner, S.P. Lownie, E.M. Demont, W. Kalata, F. Loth, D.W. Holdsworth, and D.A. Steinman, "Piv-measured versus cfd-predicted flow dynamics in anatomically realistic cerebral aneurysm models", J Biomech Eng, vol. 130, no. 2, pp. 021015, 2008.
-
(2008)
J Biomech Eng
, vol.130
, Issue.2
, pp. 021015
-
-
Ford, M.D.1
Nikolov, H.N.2
Milner, J.S.3
Lownie, S.P.4
Demont, E.M.5
Kalata, W.6
Loth, F.7
Holdsworth, D.W.8
Steinman, D.A.9
-
4
-
-
43649093138
-
3D rotational angiography: The new gold standard in the detection of additional intracranial aneurysms
-
W.J. van Rooij, M.E. Sprengers, A.N. de Gast, J.P. Peluso, and M. Sluzewski, "3D rotational angiography: the new gold standard in the detection of additional intracranial aneurysms", AJNR Am J Neuroradiol, vol. 29, no. 5, pp. 976-979, 2008.
-
(2008)
AJNR Am J Neuroradiol
, vol.29
, Issue.5
, pp. 976-979
-
-
van Rooij, W.J.1
Sprengers, M.E.2
de Gast, A.N.3
Peluso, J.P.4
Sluzewski, M.5
-
5
-
-
34248652981
-
Non-parametric geodesic active regions: Method and evaluation for cerebral aneurysms segmentation in 3DRA and CTA
-
M. Hernandez and A.F. Frangi, "Non-parametric geodesic active regions: method and evaluation for cerebral aneurysms segmentation in 3DRA and CTA", Med Image Anal, vol. 11, no. 3, pp. 224-241, 2007.
-
(2007)
Med Image Anal
, vol.11
, Issue.3
, pp. 224-241
-
-
Hernandez, M.1
Frangi, A.F.2
-
6
-
-
38349025486
-
Diagnostic accuracy of CT angiography with matched mask bone elimination for detection of intracranial aneurysms: Comparison with digital subtraction angiography and 3D rotational angiography
-
M. Romijn, H.A. Gratama van Andel, M.A. van Walderveen, M.E. Sprengers, J.C. van Rijn, W.J. van Rooij, H.W. Venema, C.A. Grimbergen, G.J. den Heeten, and C.B. Majoie, "Diagnostic accuracy of CT angiography with matched mask bone elimination for detection of intracranial aneurysms: comparison with digital subtraction angiography and 3D rotational angiography", AJNR Am J Neuroradiol, vol. 29, no. 1, pp. 134-139, 2008.
-
(2008)
AJNR Am J Neuroradiol
, vol.29
, Issue.1
, pp. 134-139
-
-
Romijn, M.1
Gratama van Andel, H.A.2
van Walderveen, M.A.3
Sprengers, M.E.4
van Rijn, J.C.5
van Rooij, W.J.6
Venema, H.W.7
Grimbergen, C.A.8
den Heeten, G.J.9
Majoie, C.B.10
-
7
-
-
33746121289
-
Wall shear stress-an important determinant of endothelial cell function and structure-in the arterial system in vivo. discrepancies with theory
-
R.S. Reneman, T. Arts, and A.P. Hoeks, "Wall shear stress-an important determinant of endothelial cell function and structure-in the arterial system in vivo. discrepancies with theory", J Vasc Res, vol. 43, no. 3, pp. 251-269, 2006.
-
(2006)
J Vasc Res
, vol.43
, Issue.3
, pp. 251-269
-
-
Reneman, R.S.1
Arts, T.2
Hoeks, A.P.3
-
8
-
-
0021966255
-
Pulsatile flow and atherosclerosis in the human carotid bifurcation. positive correlation between plaque location and low oscillating shear stress
-
D.N. Ku, D.P. Giddens, C.K. Zarins, and S. Glagov, "Pulsatile flow and atherosclerosis in the human carotid bifurcation. positive correlation between plaque location and low oscillating shear stress", Arteriosclerosis, vol. 5, no. 3, pp. 293-302, 1985.
-
(1985)
Arteriosclerosis
, vol.5
, Issue.3
, pp. 293-302
-
-
Ku, D.N.1
Giddens, D.P.2
Zarins, C.K.3
Glagov, S.4
|