메뉴 건너뛰기




Volumn 2, Issue 3, 2009, Pages 192-199

Multiplex mini Y short tandem repeat haplotyping using fluorescence energy transfer labeled primers

Author keywords

Capillary electrophoretic microdevice; Fluorescence energy transfer; Mini Y STR haplotyping; Multiple polymerase chain reaction; Short tandem repeat

Indexed keywords


EID: 70449105688     PISSN: 19760280     EISSN: 20927843     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (6)

References (7)
  • 1
    • 45749083353 scopus 로고    scopus 로고
    • Fluorescence energy transfer-labeled primers for high-performance forensic DNA profiling
    • Stephanie, H.I. et al. Fluorescence energy transfer-labeled primers for high-performance forensic DNA profiling. Electrophoresis 29, 2251-2259 (2008).
    • (2008) Electrophoresis , vol.29 , pp. 2251-2259
    • Stephanie, H.I.1
  • 2
    • 33847676392 scopus 로고    scopus 로고
    • Integrated portable polymerase chain reaction-capillary electrophoresis micro-system for rapid forensic short tandem repeat typing
    • Peng, L. et al. Integrated portable polymerase chain reaction-capillary electrophoresis micro-system for rapid forensic short tandem repeat typing. Anal. Chem. 79, 1881-1889 (2007).
    • (2007) Anal. Chem. , vol.79 , pp. 1881-1889
    • Peng, L.1
  • 3
    • 33745754510 scopus 로고    scopus 로고
    • Rapid and high-throughput forensic short tandem repeat typing using a 96-lane microfabricated capillary array electrophoresis microdevice
    • Yeung, S.H.I. et al. Rapid and high-throughput forensic short tandem repeat typing using a 96-lane microfabricated capillary array electrophoresis microdevice. J. Foresic Sci. 51, 740-747 (2006).
    • (2006) J. Foresic Sci , vol.51 , pp. 740-747
    • Yeung, S.H.I.1
  • 4
    • 0037230017 scopus 로고    scopus 로고
    • DNA profiling of azoospermic semen samples from vasectomized males by using Y-PLEX 6 amplification kit
    • Shewale, J.G., Sikka, S.C., Schneida, E. & Sinha, S.K. DNA profiling of azoospermic semen samples from vasectomized males by using Y-PLEX 6 amplification kit. J. Forensic Sci. 48, 127-129 (2003).
    • (2003) J. Forensic Sci , vol.48 , pp. 127-129
    • Shewale, J.G.1    Sikka, S.C.2    Schneida, E.3    Sinha, S.K.4
  • 5
    • 0035452397 scopus 로고    scopus 로고
    • Validation and casework application of a Y chromosome specific STR multiplex
    • Prinz, M., Ishii, A., Coleman, A., Baum, H.J. & Shaler, R.C. Validation and casework application of a Y chromosome specific STR multiplex. Forensic Sci. Int. 210, 177-188 (2001).
    • (2001) Forensic Sci. Int , vol.210 , pp. 177-188
    • Prinz, M.1    Ishii, A.2    Coleman, A.3    Baum, H.J.4    Shaler, R.C.5
  • 6
    • 33846922808 scopus 로고    scopus 로고
    • Y-STR analysis of degraded DNA using reducedsize amplicons
    • Park, M.J., Lee, H.Y., Chung, U., Kang, S.-C. & Shin, K.J. Y-STR analysis of degraded DNA using reducedsize amplicons. Int. J. Legal Med. 121, 152-157 (2007).
    • (2007) Int. J. Legal Med , vol.121 , pp. 152-157
    • Park, M.J.1    Lee, H.Y.2    Chung, U.3    Kang, S.-C.4    Shin, K.J.5
  • 7
    • 0035873237 scopus 로고    scopus 로고
    • Energy transfer cassettes for facile labeling of sequencing and PCR primers
    • Berti, L., Xie, J., Medintz, I.L., Glazer, A.N. & Mathies, R.A. Energy transfer cassettes for facile labeling of sequencing and PCR primers. Anal. Biochem. 292, 188-197 (2001).
    • (2001) Anal. Biochem , vol.292 , pp. 188-197
    • Berti, L.1    Xie, J.2    Medintz, I.L.3    Glazer, A.N.4    Mathies, R.A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.