메뉴 건너뛰기




Volumn 13, Issue 4, 2004, Pages 667-675

Evaluation of an in-vitro thrombosis assessment procedure by application to the medtronic paralleltmand st. jude medical valves

Author keywords

[No Author keywords available]

Indexed keywords

AORTA VALVE; ARTICLE; BIOLOGICAL MODEL; COMPARATIVE STUDY; DEVICE REMOVAL; EVALUATION; HEART VALVE PROSTHESIS; HEART VALVE REPLACEMENT; HUMAN; MITRAL VALVE; POSTOPERATIVE COMPLICATION; PROSTHESIS; PROSTHESIS FAILURE; PULSATILE FLOW; THROMBOSIS; TIME; VALVULAR HEART DISEASE;

EID: 7044264618     PISSN: 09668519     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (7)

References (24)
  • 1
    • 0030276877 scopus 로고    scopus 로고
    • The Medtronic Parallel (TM) valve and the lessons learned
    • Bodnar E. The Medtronic Parallel (TM) valve and the lessons learned. J Heart Valve Dis 1996;5:572-573
    • (1996) J Heart Valve Dis , vol.5 , pp. 572-573
    • Bodnar, E.1
  • 2
    • 0029851046 scopus 로고    scopus 로고
    • Hemodynamic evaluation of a new bileaflet valve prosthesis: An acute animal experimental study
    • Hasenkam JM, Nygaard H, Terp K, Riis C, Paulsen PK. Hemodynamic evaluation of a new bileaflet valve prosthesis: An acute animal experimental study. J Heart Valve Dis 1996;5:574-580 (Pubitemid 26393689)
    • (1996) Journal of Heart Valve Disease , vol.5 , Issue.6 , pp. 574-580
    • Hasenkam, J.M.1    Nygaard, H.2    Terp, K.3    Riis, C.4    Paulsen, P.K.5
  • 3
    • 0031972336 scopus 로고    scopus 로고
    • Current state of in vivo preclinical heart valve evaluation
    • Salerno CT, Droel J, Bianco RW. Current state of in vivo preclinical heart valve evaluation. J Heart Valve Dis 1998;7:158-162 (Pubitemid 28168492)
    • (1998) Journal of Heart Valve Disease , vol.7 , Issue.2 , pp. 158-162
    • Salerno, C.T.1    Droel, J.2    Bianco, R.W.3
  • 7
    • 0034181001 scopus 로고    scopus 로고
    • An in vitro study of the hinge and near-field forward flow dynamics of the St. Jude Medicaltarget Regenttrade bileaflet mechanical heart valve
    • ElUs JT, Travis BR, Yoganathan AP. An in vitro study of the hinge and near-field forward flow dynamics of the St. Jude MedicaltargetRegent™ bileaflet mechanical heart valve. Ann Biomed Eng 2000;28:524-532
    • (2000) Ann Biomed Eng , vol.28 , pp. 524-532
    • ElUs, J.T.1    Travis, B.R.2    Yoganathan, A.P.3
  • 12
    • 0020611086 scopus 로고
    • A blood analogue for the experimental study of flow-related thrombosis at prosthetic heart valves
    • Lewis JMO, MacLeod N. A blood analogue for the experimental study of flow-related thrombosis at prosthetic heart valves. Cardiovasc Res 1983;17:466-475 (Pubitemid 13039060)
    • (1983) Cardiovascular Research , vol.17 , Issue.8 , pp. 466-475
    • Lewis, J.M.O.1    Macleod, N.2
  • 13
    • 0016864942 scopus 로고
    • Structural aspects of the milk clotting process. Comparative features with the blood clotting process
    • Jolies P. Structural aspects of the milk clotting process. Comparative features with the blood clotting process. MoI Cell Biochem 1975;7:73-85
    • (1975) MoI Cell Biochem , vol.7 , pp. 73-85
    • Jolies, P.1
  • 15
    • 0034080224 scopus 로고    scopus 로고
    • Ultrasonic determination of clot deposition rates in a milk-based, in- Vitro procedure for thrombogenicity assessment
    • Christy JRE, Marosek KW. Ultrasonic determination of clot deposition rates in a milk-based, in-vitro procedure for thrombogenicity assessment. J Heart Valve Dis 2000;9:379-388 (Pubitemid 30395130)
    • (2000) Journal of Heart Valve Disease , vol.9 , Issue.3 , pp. 379-388
    • Christy, J.R.E.1    Marosek, K.W.2
  • 19
    • 0029552024 scopus 로고
    • Results with mechanical cardiac valvular prostheses
    • DOI 10.1016/0003-4975(95)00766-0
    • Akins CW. Results with mechanical cardiac valvular prostheses. Ann Thorac Surg 1995;60:1836-1844 (Pubitemid 26079175)
    • (1995) Annals of Thoracic Surgery , vol.60 , Issue.6 , pp. 1836-1844
    • Akins, C.W.1
  • 21
    • 0019023993 scopus 로고
    • Entrapment of leaflet of St. Jude medical cardiac valve prosthesis by miniscule thrombus: Report of two cases
    • Nunez L, Iglesias A, Sotillo J. Entrapment of leaflet of St. Jude Medical cardiac valve prosthesis by rniniscule thrombus: Report of two cases. Ann Thorac Surg 1980;29:567-569 (Pubitemid 10063448)
    • (1980) Annals of Thoracic Surgery , vol.29 , Issue.6 , pp. 567-569
    • Nunez, L.1    Iglesias, A.2    Sotillo, J.3
  • 22
    • 0025777562 scopus 로고
    • Obstruction of mechanical heart valve prostheses: Clinical aspects and surgical management
    • .Deviri E, Sareli P, Wisenbaugh T, Cronje SL. Obstruction of mechanical heart valve prostheses: Clinical aspects and surgical management. J Am Coll Cardiol 1991;17:646-650
    • (1991) J Am Coll Cardiol , vol.17 , pp. 646-650
    • Deviri, E.1    Sareli, P.2    Wisenbaugh, T.3    Cronje, S.L.4
  • 23
    • 0035191753 scopus 로고    scopus 로고
    • Effect of aortic valve replacement on plasma soluble P-selectin, von Willebrand factor, and fibrinogen
    • DOI 10.1016/S0002-9149(00)01283-2, PII S0002914900012832
    • Goldsmith IRA, Blann AD, Patel RL, Lip GYH. Effect of aortic valve replacement on plasma soluble p-selectin, von Willebrand factor, and fibrinogen. Am J Cardiol 2001;87:107-110 (Pubitemid 32013095)
    • (2001) American Journal of Cardiology , vol.87 , Issue.1 , pp. 107-110
    • Goldsmith, I.R.A.1    Blann, A.D.2    Patel, R.L.3    Lip, G.Y.H.4
  • 24
    • 0026011124 scopus 로고
    • Blood rheology after cardiac valve replacement with mechanical prostheses or bioprostheses
    • Koppensteiner R, Moritz A, Schlick W, et al. Blood rheology after cardiac valve replacement with mechanical prostheses or bioprostheses. Am J Cardiol 1991;67:79-83
    • (1991) Am J Cardiol , vol.67 , pp. 79-83
    • Koppensteiner, R.1    Moritz, A.2    Schlick, W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.