메뉴 건너뛰기




Volumn 21, Issue 9, 1998, Pages 548-552

In vitro thrombogenicity testing of artificial organs

Author keywords

Blood pump; In vitro test; Mechanical heart valve; Thrombogenicity; Thrombus formation

Indexed keywords

ARTIFICIAL HEART; BLOOD VESSELS; PUMPS; VALVES (MECHANICAL);

EID: 0031786979     PISSN: 03913988     EISSN: None     Source Type: Journal    
DOI: 10.1177/039139889802100910     Document Type: Article
Times cited : (34)

References (9)
  • 1
    • 0025082464 scopus 로고
    • In vitro assessment of centrifugal pumps for ventricular assist
    • Jacob H, Kutchera Y, Patzer B, Prellwitz W, Oelert H. In vitro assessment of centrifugal pumps for ventricular assist. Artif Organs 1990; 14(4): 278-83.
    • (1990) Artif Organs , vol.14 , Issue.4 , pp. 278-283
    • Jacob, H.1    Kutchera, Y.2    Patzer, B.3    Prellwitz, W.4    Oelert, H.5
  • 3
    • 0026239708 scopus 로고
    • Influence of centrifugal blood pumps on the elasticity of erythrocytes
    • Schima H, Schlusche C, Jeremejev BV et al. Influence of centrifugal blood pumps on the elasticity of erythrocytes. ASAIO Trans 1991; 37(4): 658-61.
    • (1991) ASAIO Trans , vol.37 , Issue.4 , pp. 658-661
    • Schima, H.1    Schlusche, C.2    Jeremejev, B.V.3
  • 4
    • 0027162867 scopus 로고
    • In vitro hematological testing of Rotary blood pumps: Remarks on standardization and Data Interpretation
    • Mueller MR, Schima H, Engelhardt H, et al. In vitro hematological testing of Rotary blood pumps: remarks on standardization and Data Interpretation. Artif Organs 1993; 17(2): 103-10.
    • (1993) Artif Organs , vol.17 , Issue.2 , pp. 103-110
    • Mueller, M.R.1    Schima, H.2    Engelhardt, H.3
  • 5
    • 0024705694 scopus 로고
    • An in vitro test model to study the performance and thrombogenicity of Cardiovascular Devices
    • Swier P, Bos WJ, Mohammad SF, Olsen DB, Kolff WJ. An in vitro test model to study the performance and thrombogenicity of Cardiovascular Devices. ASAIO Trans 1989; 35: 683-7.
    • (1989) ASAIO Trans , vol.35 , pp. 683-687
    • Swier, P.1    Bos, W.J.2    Mohammad, S.F.3    Olsen, D.B.4    Kolff, W.J.5
  • 6
    • 0027230918 scopus 로고
    • Mechanical blood traumatization by tubing and throttles in in vitro pump tests: Experimental results and implications for hemolysis theory
    • Schima H, Müller MR, Tsangaris S, et al. Mechanical blood traumatization by tubing and throttles in in vitro pump tests: experimental results and implications for hemolysis theory. Artif Organs 1993; 17(3): 164-70.
    • (1993) Artif Organs , vol.17 , Issue.3 , pp. 164-170
    • Schima, H.1    Müller, M.R.2    Tsangaris, S.3
  • 7
    • 0031001839 scopus 로고    scopus 로고
    • In vitro thrombogenic evaluation of centrifugal pumps
    • Tayama E, Ohtsubo S. Nakazawa, T et al. In vitro thrombogenic evaluation of centrifugal pumps. Artif Organs 1997; 21(5): 418-20.
    • (1997) Artif Organs , vol.21 , Issue.5 , pp. 418-420
    • Tayama, E.1    Ohtsubo, S.2    Nakazawa, T.3
  • 9
    • 0027171745 scopus 로고
    • In vitro investigation of thrombogenesis in rotary blood pumps
    • Schima H, Siegl H, Mohammad SF, et al. In vitro investigation of thrombogenesis in rotary blood pumps. Artif Organs 1993; 17:605-8.
    • (1993) Artif Organs , vol.17 , pp. 605-608
    • Schima, H.1    Siegl, H.2    Mohammad, S.F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.