Volumn 36, Issue 11, 2009, Pages 5198-5213

Physical models, cross sections, and numerical approximations used in MCNP and GEANT4 Monte Carlo codes for photon and electron absorbed fraction calculation

Author keywords

Absorbed fraction; Dosimetry; GEANT4; MCNP; Monte Carlo

Indexed keywords

DOSIMETRY; HISTOLOGY; NUCLEAR MEDICINE; NUMERICAL METHODS; NUMERICAL MODELS; PHOTONS; TISSUE;

EID: 70350703148     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3242304     Document Type: Article
Times cited : (22)

References (33)
  • 1
    • 14644393645 scopus 로고    scopus 로고
    • ORANGE: A Monte Carlo dose engine for radiotherapy
    • DOI 10.1088/0031-9155/50/4/005
    • W. van der Zee, A. Hogenbirk, and S. C. van der Marck, " ORANGE: A Monte Carlo dose engine for radiotherapy.," Phys. Med. Biol. 50, 625-641 (2005). 10.1088/0031-9155/50/4/005 (Pubitemid 40309201)
    • (2005) Physics in Medicine and Biology , vol.50 , Issue.4 , pp. 625-641
    • Van Der Zee, W.1    Hogenbirk, A.2    Van Der Marck, S.C.3
  • 3
    • 0001236265 scopus 로고
    • MIRD Pamphlet No. 2: Energy deposition in water by photons from point isotropic sources
    • M. Berger, " MIRD Pamphlet No. 2: Energy deposition in water by photons from point isotropic sources.," J. Nucl. Med. 9, 15-25 (1968).
    • (1968) J. Nucl. Med. , vol.9 , pp. 15-25
    • Berger, M.1
  • 5
    • 0025882033 scopus 로고
    • Estimates of beta absorbed fractions in small tissue volumes for selected radionuclides
    • G. Akabani, J. W. Poston, and W. E. Bolch, " Estimates of beta absorbed fractions in small tissue volumes for selected radionuclides.," J. Nucl. Med. 32, 835-839 (1991).
    • (1991) J. Nucl. Med. , vol.32 , pp. 835-839
    • Akabani, G.1    Poston, J.W.2    Bolch, W.E.3
  • 8
    • 0027958549 scopus 로고
    • Absorbed fractions for electrons and beta particles in spheres of various sizes
    • J. A. Siegel and M. G. Stabin, " Absorbed fractions for electrons and beta particles in spheres of various sizes.," J. Nucl. Med. 35, 52-56 (1994).
    • (1994) J. Nucl. Med. , vol.35 , pp. 52-56
    • Siegel, J.A.1    Stabin, M.G.2
  • 9
    • 0033972633 scopus 로고    scopus 로고
    • Re-evaluation of absorbed fractions for photons and electrons in spheres of various sizes
    • M. G. Stabin and M. W. Konijnenberg, " Re-evaluation of absorbed fractions for photons and electrons in spheres of various sizes.," J. Nucl. Med. 41, 149-160 (2000).
    • (2000) J. Nucl. Med. , vol.41 , pp. 149-160
    • Stabin, M.G.1    Konijnenberg, M.W.2
  • 12
  • 13
    • 0038377458 scopus 로고    scopus 로고
    • GEANT4-A simulation toolkit
    • 10.1016/S0168-9002(03)01368-8
    • S. Agostinelli, " GEANT4-A simulation toolkit.," Nucl. Instrum. Methods Phys. Res. A 506, 250-303 (2003). 10.1016/S0168-9002(03)01368-8
    • (2003) Nucl. Instrum. Methods Phys. Res. A , vol.506 , pp. 250-303
    • Agostinelli, S.1
  • 15
    • 0000762173 scopus 로고
    • Monte Carlo calculations of the penetration and diffusion of fast charged particles
    • in, edited by B. Alder, S. Fernbach, and M. Rotenberg (Academic, New York), Vol..
    • M. J. Berger, " Monte Carlo calculations of the penetration and diffusion of fast charged particles.," in Methods in Computational Physics, edited by, B. Alder, S. Fernbach, and, M. Rotenberg, (Academic, New York, 1993), Vol. 1.
    • (1993) Methods in Computational Physics , vol.1
    • Berger, M.J.1
  • 16
    • 0031901461 scopus 로고    scopus 로고
    • Comparison of EGS4 and MCNP Monte Carlo codes when calculating radiotherapy depth doses
    • DOI 10.1088/0031-9155/43/5/024, PII S0031915598891082
    • P. A. Love, D. G. Lewis, I. A. M. Al-Affan, and C. W. de Smith, " Comparison of EGS4 and MCNP Monte Carlo codes when calculating radiotherapy depth doses.," Phys. Med. Biol. 43, 1351-1357 (1998). 10.1088/0031-9155/43/ 5/024 (Pubitemid 28223577)
    • (1998) Physics in Medicine and Biology , vol.43 , Issue.5 , pp. 1351-1357
    • Love, P.A.1    Lewis, D.G.2    Al-Affan, I.A.M.3    Smith, C.W.4
  • 17
    • 0033002725 scopus 로고    scopus 로고
    • Comparisons between MCNP, EGS4 and experiment for clinical electron beams
    • DOI 10.1088/0031-9155/44/3/013, PII S0031915599941192
    • R. Jeraj, P. J. Keall, and P. M. Ostwald, " Comparison between MCNP, EGS4 and experiment for clinical electron beams.," Phys. Med. Biol. 44, 705-717 (1999). 10.1088/0031-9155/44/3/013 (Pubitemid 29133063)
    • (1999) Physics in Medicine and Biology , vol.44 , Issue.3 , pp. 705-717
    • Jeraj, R.1    Keall, P.J.2    Ostwald, P.M.3
  • 18
    • 0037035394 scopus 로고    scopus 로고
    • A comparison of MCNP4C electron transport with ITS 30 and experiment at incident energies between 100 keV and 20 MeV: Influence of voxel size, substeps and energy indexing algorithm
    • DOI 10.1088/0031-9155/47/9/303, PII S0031915502316294
    • D. R. Schaart, J. T. Jansen, J. Zoetelief, and P. F. de Leege, " A comparison of MCNP4C electron transport with ITS 3.0 and experiment at incident energies between 100 keV and 20 MeV: Influence of voxel size, substeps and energy indexing algorithm.," Phys. Med. Biol. 47, 1459-1484 (2002). 10.1088/0031-9155/47/9/303 (Pubitemid 34575322)
    • (2002) Physics in Medicine and Biology , vol.47 , Issue.9 , pp. 1459-1484
    • Schaart, D.R.1    Jansen, J.Th.M.2    Zoetelief, J.3    De Leege, P.F.A.4
  • 19
    • 0037149981 scopus 로고    scopus 로고
    • An analysis of MCNP cross-sections and tally methods for low-energy photon emitters
    • DOI 10.1088/0031-9155/47/8/307, PII S0031915502257528
    • J. J. DeMarco, R. E. Wallace, and K. Boedeker, " An analysis of MCNP cross-sections and tally methods for low-energy photon emitters.," Phys. Med. Biol. 47, 1321-1332 (2002). 10.1088/0031-9155/47/8/307 (Pubitemid 34495628)
    • (2002) Physics in Medicine and Biology , vol.47 , Issue.8 , pp. 1321-1332
    • DeMarco, J.J.1    Wallace, R.E.2    Boedecker, K.3
  • 20
    • 0036798699 scopus 로고    scopus 로고
    • Parameter dependence of the MCNP electron transport in determining dose distributions
    • DOI 10.1118/1.1508798
    • N. Reynaert, H. Palmans, H. Thierens, and R. Jeraj, " Parameter dependence of the MCNP electron transport in determining dose distributions.," Med. Phys. 29, 2446-2454 (2002). 10.1118/1.1508798 (Pubitemid 35204455)
    • (2002) Medical Physics , vol.29 , Issue.10 , pp. 2446-2454
    • Reynaert, N.1    Palmans, H.2    Thierens, H.3    Jeraj, R.4
  • 21
    • 0037572354 scopus 로고    scopus 로고
    • 32P source wire used for intravascular brachytherapy with automated stepping
    • DOI 10.1118/1.1567832
    • N. F. Mourtada, C. G. Soares, S. M. Seltzer, P. M. Bergstrom, Jr., J. M. Fernández-Varea, J. Asenjo, and S. H. Lott, " Dosimetry characterization of a P32 source wire used for intravascular brachytherapy with automated stepping.," Med. Phys. 30, 959-971 (2003). 10.1118/1.1567832 (Pubitemid 36578700)
    • (2003) Medical Physics , vol.30 , Issue.5 , pp. 959-971
    • Mourtada, F.1    Soares, C.G.2    Seltzer, S.M.3    Bergstrom Jr., P.M.4    Fernandez-Verea, J.M.5    Asenjo, J.6    Lott, S.H.7
  • 22
    • 34547466654 scopus 로고    scopus 로고
    • Comparison of MCNP4C and EGSnrc Monte Carlo codes in depth-dose calculation of low energy clinical electron beams
    • DOI 10.1088/0022-3727/40/15/023, PII S0022372707446885, 023
    • N. Jabbari, B. Hashemi-Malayeri, A. R. Farajollahi, A. Kazemnejad, A. Shafaei, and S. Jabbari, " Comparison of MCNP4C and EGSnrc Monte Carlo codes in depth-dose calculation of low energy clinical electron beams.," J. Phys. D: Appl. Phys. 40, 4519-4524 (2007). 10.1088/0022-3727/40/15/023 (Pubitemid 47160479)
    • (2007) Journal of Physics D: Applied Physics , vol.40 , Issue.15 , pp. 4519-4524
    • Jabbari, N.1    Hashemi-Malayeri, B.2    Farajollahi, A.R.3    Kazemnejad, A.4    Shafaei, A.5    Jabbari, S.6
  • 23
    • 36149005290 scopus 로고
    • Multiple scattering in an infinite medium
    • 10.1103/PhysRev.78.526
    • H. W. Lewis, " Multiple scattering in an infinite medium.," Phys. Rev. 78, 526-529 (1950). 10.1103/PhysRev.78.526
    • (1950) Phys. Rev. , vol.78 , pp. 526-529
    • Lewis, H.W.1
  • 26
    • 27644584205 scopus 로고    scopus 로고
    • Comparison of Geant4 electromagnetic physics models against the NIST reference data
    • 10.1109/TNS.2005.852691
    • K. Amako, " Comparison of Geant4 electromagnetic physics models against the NIST reference data.," IEEE Trans. Nucl. Sci. 52, 910-918 (2005). 10.1109/TNS.2005.852691
    • (2005) IEEE Trans. Nucl. Sci. , vol.52 , pp. 910-918
    • Amako, K.1
  • 27
    • 14644405544 scopus 로고    scopus 로고
    • Accuracy of the photon and electron physics in GEANT4 for radiotherapy applications
    • DOI 10.1118/1.1895796
    • N. E. Poon and F. Verhaegen, " Accuracy of the photon and electron physics in Geant4 for radiotherapy applications.," Med. Phys. 32, 1696-1711 (2005). 10.1118/1.1895796 (Pubitemid 40880563)
    • (2005) Medical Physics , vol.32 , Issue.6 , pp. 1696-1711
    • Poon, E.1    Verhaegen, F.2
  • 32
    • 1142287542 scopus 로고    scopus 로고
    • Benchmark of PENELOPE code for low-energy photon transport: Dose comparison with MCNP4 and EGS4
    • DOI 10.1088/0031-9155/49/3/003, PII S0031915504705023
    • S. J. Ye, I. A. Brezovich, P. Pareek, and S. A. Naqvi, " Benchmark of PENELOPE code for low-energy photon transport: Dose comparisons with MCNP4 and EGS4.," Phys. Med. Biol. 49, 387-397 (2004). 10.1088/0031-9155/49/3/003 (Pubitemid 38208149)
    • (2004) Physics in Medicine and Biology , vol.49 , Issue.3 , pp. 387-397
    • Ye, S.-J.1    Brezovich, I.A.2    Pareek, P.3    Naqvi, S.A.4
  • 33
    • 0003682469 scopus 로고
    • ICRU Report No. 44, "" (International Commission on Radiation Units and Measurements, Bethesda, MD).
    • ICRU Report No. 44, " Tissue substitutes in radiation dosimetry and measurement. " (International Commission on Radiation Units and Measurements, Bethesda, MD, 1989).
    • (1989) Tissue Substitutes in Radiation Dosimetry and Measurement