메뉴 건너뛰기




Volumn 22, Issue , 2008, Pages 736-739

A feasibility study on the delectability of edema using magnetic induction tomography using an analytical model

Author keywords

Brain edema; Forward problem; Magnetic induction tomography

Indexed keywords

ANALYTICAL MODEL; ANALYTICAL SOLUTIONS; BOUNDARY INFORMATION; BRAIN EDEMA; CEREBRAL SPINAL FLUIDS; CLINICAL APPLICATION; COMMERCIAL PACKAGES; CONCENTRIC SHELLS; CONDUCTIVITY CHANGES; COUPLED FIELDS; DETECTABILITY; ELECTROMAGNETIC FIELD PROBLEMS; FEASIBILITY STUDIES; FORWARD PROBLEM; GRAY MATTER; HEAD MODEL; LOW CONDUCTIVITY; LOW FREQUENCY; MAGNETIC INDUCTION TOMOGRAPHY; MULTILAYER MODELS; RELATIVE SENSITIVITY; SOLUTION STABILITY; TISSUE STRUCTURE; WHITE MATTER;

EID: 70350662907     PISSN: 16800737     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1007/978-3-540-89208-3_176     Document Type: Conference Paper
Times cited : (6)

References (7)
  • 1
    • 70350659902 scopus 로고    scopus 로고
    • The Nhs Confederation, (2008) The national stroke Strategy
    • The Nhs Confederation, (2008) The national stroke Strategy
  • 2
    • 0035066973 scopus 로고    scopus 로고
    • Bedside monitoring techniques in severe braininjured patients
    • Vinas F.C, (2001) Bedside monitoring techniques in severe braininjured patients. Neuro. Res. 23 157-66
    • (2001) Neuro. Res , vol.23 , pp. 157-166
    • Vinas, F.C.1
  • 3
    • 33745165595 scopus 로고    scopus 로고
    • Reconstruction of the shape spectra using multi-frequency magnetic induction tomography
    • Brunner P, Merwa R, Missner A et al (2006) Reconstruction of the shape spectra using multi-frequency magnetic induction tomography. Meas. Sci. Technol 27 S237-S248.
    • (2006) Meas. Sci. Technol , vol.27
    • Brunner, P.1    Merwa, R.2    Missner, A.3
  • 4
    • 0035422248 scopus 로고    scopus 로고
    • Magnetic induction tomography
    • Griffiths H, (2001) Magnetic induction tomography. Meas. Sci. Technol. 12:1126-1131.
    • (2001) Meas. Sci. Technol , vol.12 , pp. 1126-1131
    • Griffiths, H.1
  • 5
    • 0038777513 scopus 로고    scopus 로고
    • Magnetic induction tomography: Phase versus vector-voltmeter measurement techniques
    • UK
    • Watson S, Williams R.J, Griffiths H et al, (2003) "Magnetic induction tomography: phase versus vector-voltmeter measurement techniques," Physiological measurement 24 (2): 555-64, UK
    • (2003) Physiological measurement , vol.24 , Issue.2 , pp. 555-564
    • Watson, S.1    Williams, R.J.2    Griffiths, H.3
  • 6
    • 0029909341 scopus 로고    scopus 로고
    • The dielectric properties of biological tissues. II. Measurements in the frequency range 10 Hz to 20GHz, Phys
    • Gabriel S, Lau R.W, Gabriel C et al, "The dielectric properties of biological tissues. II. Measurements in the frequency range 10 Hz to 20GHz", Phys. Biol, Med 41, 2251-2269.1996
    • (1996) Biol, Med , vol.41 , pp. 2251-2269
    • Gabriel, S.1    Lau, R.W.2    Gabriel, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.