메뉴 건너뛰기




Volumn 27, Issue 5, 2006, Pages

Reconstruction of the shape of conductivity spectra using differential multi-frequency magnetic induction tomography

Author keywords

Conductivity spectrum; Frequency differential; Magnetic induction tomography (MIT)

Indexed keywords

ELECTRIC IMPEDANCE TOMOGRAPHY; IMAGE RECONSTRUCTION; INVERSE PROBLEMS; MAGNETIC FIELDS; NUMERICAL METHODS; TISSUE;

EID: 33745165595     PISSN: 09673334     EISSN: 13616579     Source Type: Journal    
DOI: 10.1088/0967-3334/27/5/S20     Document Type: Conference Paper
Times cited : (42)

References (9)
  • 1
    • 0035422248 scopus 로고    scopus 로고
    • Magnetic induction tomography
    • Griffiths H 2001 Magnetic induction tomography Meas. Sci. Technol. 12 1126-31
    • (2001) Meas. Sci. Technol. , vol.26 , pp. 1126-1131
    • Griffiths, H.1
  • 3
    • 2342624763 scopus 로고    scopus 로고
    • Numerical simulation of the eddy current problem in magnetic induction tomography for biomedical applications by edge elements
    • Hollaus K, Magele C, Merwa R and Scharfetter H 2004 Numerical simulation of the eddy current problem in magnetic induction tomography for biomedical applications by edge elements IEEE Trans. Magn. 40 623-6
    • (2004) IEEE Trans. Magn. , vol.40 , Issue.2 , pp. 623-626
    • Hollaus, K.1    Magele, C.2    Merwa, R.3    Scharfetter, H.4
  • 4
    • 0038439638 scopus 로고    scopus 로고
    • Numerical solution of the general 3D eddy current problem for magnetic induction tomography (spectroscopy)
    • Merwa R, Hollaus K, Brandstätter B and Scharfetter H 2003 Numerical solution of the general 3D eddy current problem for magnetic induction tomography (spectroscopy) Physiol. Meas. 24 545-54
    • (2003) Physiol. Meas. , vol.24 , Issue.2 , pp. 545-554
    • Merwa, R.1    Hollaus, K.2    Brandstätter, B.3    Scharfetter, H.4
  • 5
    • 23044490284 scopus 로고    scopus 로고
    • Solution of the inverse problem of magnetic induction tomography (MIT)
    • Merwa R, Hollaus K, Brunner P and Scharfetter H 2005 Solution of the inverse problem of magnetic induction tomography (MIT) Physiol. Meas. 26 241-50
    • (2005) Physiol. Meas. , vol.26 , pp. 241-250
    • Merwa, R.1    Hollaus, K.2    Brunner, P.3    Scharfetter, H.4
  • 8
    • 0043165089 scopus 로고    scopus 로고
    • Biological tissue characterization by magnetic induction spectroscopy (MIS): Requirements and limitations
    • Scharfetter H, Casãas R and Rosell J 2003 Biological tissue characterization by magnetic induction spectroscopy (MIS): requirements and limitations IEEE Trans. Biomed. Eng. 50 870-80
    • (2003) IEEE Trans. Biomed. Eng. , vol.50 , Issue.7 , pp. 870-880
    • Scharfetter, H.1    Casãas, R.2    Rosell, J.3
  • 9
    • 23044452479 scopus 로고    scopus 로고
    • A new type of gradiometer for the receiving circuit of magnetic induction tomography (MIT)
    • Scharfetter H, Merwa R and Pilz K 2005 A new type of gradiometer for the receiving circuit of magnetic induction tomography (MIT) Physiol. Meas. 26 307-18
    • (2005) Physiol. Meas. , vol.26 , pp. 307-318
    • Scharfetter, H.1    Merwa, R.2    Pilz, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.