메뉴 건너뛰기




Volumn 22, Issue , 2008, Pages 2368-2371

Adjustable diffusion barrier for controlled drug release in spastic and pain therapy

Author keywords

Artificial Muscle; Conductive Polymer; Drug Delivery; Valve

Indexed keywords

APERTURE AREA; ARTIFICIAL MUSCLE; CONDUCTIVE POLYMER; CONTROLLED DRUG RELEASE; DIFFUSION RATE; DRUG MOLECULES; ELECTRO-ACTIVE POLYMERS; LOW POWER; LOW-POWER CONSUMPTION; MODES OF OPERATION; PRESSURELESS; TIME-RESOLVED; VALVE;

EID: 70350628886     PISSN: 16800737     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1007/978-3-540-89208-3_568     Document Type: Conference Paper
Times cited : (3)

References (15)
  • 1
    • 0037374817 scopus 로고    scopus 로고
    • Where a Pill Won't Reach
    • Langer, R. (2003) Where a Pill Won't Reach. Sci Am 288:50-57
    • (2003) Sci Am , vol.288 , pp. 50-57
    • Langer, R.1
  • 2
    • 0141765877 scopus 로고    scopus 로고
    • Small-scale systems for in vivo drug delivery
    • LaVan D A, McGuire T, Langer R (2003) Small-scale systems for in vivo drug delivery. Nat Biotechnol 21:1184-1191
    • (2003) Nat Biotechnol , vol.21 , pp. 1184-1191
    • LaVan, D.A.1    McGuire, T.2    Langer, R.3
  • 4
    • 0029822588 scopus 로고    scopus 로고
    • Long-term effects of continuous intrathecal opioid treatment in chronic pain of nonmalignant etiology
    • Winkelmueller M, Winkelmueller W (1996) Long-term effects of continuous intrathecal opioid treatment in chronic pain of nonmalignant etiology. J Neurosurg 85:458-467
    • (1996) J Neurosurg , vol.85 , pp. 458-467
    • Winkelmueller, M.1    Winkelmueller, W.2
  • 5
    • 7244260312 scopus 로고    scopus 로고
    • Long term effect (more than five years) of intrathecal baclofen on impairment, disability, and quality of life in patients with severe spasticity of spinal origin
    • Zahavi A, Geertzen J H, Middel B et al. (2004) Long term effect (more than five years) of intrathecal baclofen on impairment, disability, and quality of life in patients with severe spasticity of spinal origin. J Neurol Neurosurg Psychiatry 75:1553-1557
    • (2004) J Neurol Neurosurg Psychiatry , vol.75 , pp. 1553-1557
    • Zahavi, A.1    Geertzen, J.H.2    Middel, B.3
  • 6
    • 28444489991 scopus 로고    scopus 로고
    • Electrothermallyactivated microchips for implantable drug delivery and biosensing
    • Maloney J M, Uhland S A, Polito B F et al. (2005) Electrothermallyactivated microchips for implantable drug delivery and biosensing. J Control Release 109:244-255
    • (2005) J Control Release , vol.109 , pp. 244-255
    • Maloney, J.M.1    Uhland, S.A.2    Polito, B.F.3
  • 8
    • 0034250669 scopus 로고    scopus 로고
    • Microactuators toward microvalves for responsive controlled drug delivery
    • Low L, Seetharaman S, He K, Madou M J (2000) Microactuators toward microvalves for responsive controlled drug delivery. Sens. Actuators B 67:149-160
    • (2000) Sens. Actuators B , vol.67 , pp. 149-160
    • Low, L.1    Seetharaman, S.2    He, K.3    Madou, M.J.4
  • 9
    • 33645733768 scopus 로고    scopus 로고
    • Chronic, programmed polypeptide delivery from an implanted, multireservoir microchip device
    • Prescott J H, Lipka S, Baldwin S et al. (2006) Chronic, programmed polypeptide delivery from an implanted, multireservoir microchip device. Nat Biotechnol 24:437-438
    • (2006) Nat Biotechnol , vol.24 , pp. 437-438
    • Prescott, J.H.1    Lipka, S.2    Baldwin, S.3
  • 10
    • 43049091165 scopus 로고    scopus 로고
    • Long term stability and in vitro Release of hPTH(1-34) from a Multi-reservoir Array
    • Proos E R, Prescott J H, Staples M A (2008) Long term stability and in vitro Release of hPTH(1-34) from a Multi-reservoir Array, Pharm Res 25:1387-1395
    • (2008) Pharm Res , vol.25 , pp. 1387-1395
    • Proos, E.R.1    Prescott, J.H.2    Staples, M.A.3
  • 11
    • 20444453624 scopus 로고    scopus 로고
    • Electrochemically-induced fluid movement using polypyrrole
    • Causley J et al. (2005) Electrochemically-induced fluid movement using polypyrrole. Synth Met 151:60-64
    • (2005) Synth Met , vol.151 , pp. 60-64
    • Causley, J.1
  • 12
    • 0037451521 scopus 로고    scopus 로고
    • Conjugated Polymer Actuators for Biomedical Applications
    • Smela E (2003) Conjugated Polymer Actuators for Biomedical Applications. Adv Mater 15:481-494
    • (2003) Adv Mater , vol.15 , pp. 481-494
    • Smela, E.1
  • 13
    • 0033097692 scopus 로고    scopus 로고
    • Microfabrication of PPy microactuators and other conjugated polymer devices
    • Smela E (1999) Microfabrication of PPy microactuators and other conjugated polymer devices. J Micromech Microeng 9:1-18
    • (1999) J Micromech Microeng , vol.9 , pp. 1-18
    • Smela, E.1
  • 14
    • 0032653366 scopus 로고    scopus 로고
    • On-chip micoelectrodes for electochemnistry with moveable PPy bilayer actuators as working electodes
    • Jager E W H, Smela E, Inganäs O (1999) On-chip micoelectrodes for electochemnistry with moveable PPy bilayer actuators as working electodes. Sens Actuators B 56:73-78
    • (1999) Sens Actuators B , vol.56 , pp. 73-78
    • Jager, E.W.H.1    Smela, E.2    Inganäs, O.3
  • 15
    • 44849096479 scopus 로고    scopus 로고
    • Monolithic integration of micro-channel on disposable flow sensors for medical applications
    • Billat S, Kliche K, Gronmaier R et al. (2008) Monolithic integration of micro-channel on disposable flow sensors for medical applications. Sens Actuators A 145-146:66-74
    • (2008) Sens Actuators A , vol.145-146 , pp. 66-74
    • Billat, S.1    Kliche, K.2    Gronmaier, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.