메뉴 건너뛰기




Volumn 17 IFMBE, Issue , 2007, Pages 396-399

An excitation in differential EIT - Selection of measurement frequencies

Author keywords

Contrast; Distinguishability; EIT; Multifrequency

Indexed keywords

ELECTRIC IMPEDANCE TOMOGRAPHY;

EID: 70350463471     PISSN: 16800737     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1007/978-3-540-73841-1_103     Document Type: Conference Paper
Times cited : (3)

References (17)
  • 2
    • 0029954935 scopus 로고    scopus 로고
    • The dielectric properties of biological tissues
    • Gabriel C, Gabriel S, Corthout E (1996) The dielectric properties of biological tissues. Phys. Med. Biol. 41, 2231-2293
    • (1996) Phys. Med. Biol. , vol.41 , pp. 2231-2293
    • Gabriel, C.1    Gabriel, S.2    Corthout, E.3
  • 4
    • 1342268914 scopus 로고    scopus 로고
    • Multi-frequency electrical impedance tomography of the breast: New clinical results
    • DOI 10.1088/0967-3334/25/1/034
    • Soni N K, Hartov A, Kogel C, Poplack S P, Paulsen K D (2004) Multi-frequency electrical impedance tomography of the breast: New clinical results. Physiological Meas., 25:310-314 (Pubitemid 38252221)
    • (2004) Physiological Measurement , vol.25 , Issue.1 , pp. 301-314
    • Soni, N.K.1    Hartov, A.2    Kogel, C.3    Poplack, S.P.4    Paulsen, K.D.5
  • 6
    • 0023087220 scopus 로고
    • A dual-frequency applied potential tomography technique: Computer simulations
    • Griffiths H, Ahmed A (1987) A dual-frequency applied potential tomography technique: computer simulations. Clin. Phys. Physiol. Meas 13 Suppl. A:103-107
    • (1987) Clin. Phys. Physiol. Meas. , vol.13 , Issue.SUPPL. A , pp. 103-107
    • Griffiths, H.1    Ahmed, A.2
  • 7
    • 0024434847 scopus 로고
    • A dual-frequency EIT system
    • Griffiths H, Zhang Z (1989) A dual-frequency EIT system. Phys. Med. Bio1. 34:1465-76
    • (1989) Phys. Med. Bio1. , vol.34 , pp. 1465-1476
    • Griffiths, H.1    Zhang, Z.2
  • 9
    • 0030126713 scopus 로고    scopus 로고
    • Electrical Impedance Tomography: Regularized Imaging and Contrast Detection
    • Adler A, Guardo R (1996) Electrical Impedance Tomography: Regularized Imaging and Contrast Detection. IEEE Trans. Biomed. Eng 15:170-179
    • (1996) IEEE Trans. Biomed. Eng. , vol.15 , pp. 170-179
    • Adler, A.1    Guardo, R.2
  • 12
    • 84980246936 scopus 로고
    • NOSER: An algorithm for solving the inverse conductivity problem
    • Cheney M, Isaacson D (1990) NOSER: An algorithm for solving the inverse conductivity problem. Int. J. of Imag. Syst. & Tech. 2 66-75
    • (1990) Int. J. of Imag. Syst. & Tech. , vol.2 , pp. 66-75
    • Cheney, M.1    Isaacson, D.2
  • 14
  • 15
    • 0022734022 scopus 로고
    • Distinguishability of Conductivities by Electric Current Computed Tomography
    • Isaacson D. (1986) Distinguishability of Conductivities by Electric Current Computed Tomography. IEEE Trans. Med. Imag. MI-5(2):91-95
    • (1986) IEEE Trans. Med. Imag. , vol.MI-5 , Issue.2 , pp. 91-95
    • Isaacson, D.1
  • 16
    • 0024572263 scopus 로고
    • Dielectric properties of tissues and biological materials: A critical review
    • Foster K R, Schwan H P (1989) Dielectric properties of tissues and biological materials: a critical review. Crit. Rev. in Biomed. Eng. 17:25-104
    • (1989) Crit. Rev. in Biomed. Eng. , vol.17 , pp. 25-104
    • Foster, K.R.1    Schwan, H.P.2
  • 17
    • 0014986362 scopus 로고
    • An application of electrocardiographic lead theory to impedance plethysmography
    • Geselowitz D B (1971) An application of electrocardiographic lead theory to impedance plethysmography. IEEE Trans. Biomed. Eng. 18:38-41
    • (1971) IEEE Trans. Biomed. Eng. , vol.18 , pp. 38-41
    • Geselowitz, D.B.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.