Volumn 43, Issue 20, 2009, Pages 7791-7796

Measurements of peroxy radicals using chemical amplification - Cavity ringdown spectroscopy

Author keywords

[No Author keywords available]

Indexed keywords

AMBIENT MEASUREMENT; AMPLIFICATION FACTORS; CALIFORNIA; CAVITY RING-DOWN SPECTROSCOPY; CHAIN REACTION; CHEMICAL AMPLIFICATION; CO-PRODUCTS; CONFIDENCE LIMIT; DETECTION SENSITIVITY; FLOW REACTORS; PEROXY RADICALS; RADICAL SOURCE; TEFLON TUBING; THERMAL DECOMPOSITIONS;

EID: 70350342161     PISSN: 0013936X     EISSN: 15205851     Source Type: Journal    
DOI: 10.1021/es901146t     Document Type: Article
Times cited : (24)

References (29)
  • 3
    • 0025196911 scopus 로고
    • Numerical-analysis of ESR-spectra from atmospheric samples
    • Mihelcic, D.; Volzthomas, A.; Patz, H. W.; Kley, D. Numerical-analysis of ESR-spectra from atmospheric samples. J. Atmos. Chem. 1990, 11, 271-297.
    • (1990) J. Atmos. Chem. , vol.11 , pp. 271-297
    • Mihelcic, D.1    Volzthomas, A.2    Patz, H.W.3    Kley, D.4
  • 8
    • 0020377477 scopus 로고
    • A possible technique for the measurement of atmospheric peroxy radicals
    • Cantrell, C. A.; Stedman, D. H. A possible technique for the measurement of atmospheric peroxy radicals. Geophys. Res. Lett. 1982, 9, 846-849.
    • (1982) Geophys. Res. Lett. , vol.9 , pp. 846-849
    • Cantrell, C.A.1    Stedman, D.H.2
  • 9
    • 0021461838 scopus 로고
    • Measurement of atmospheric peroxy radicals by chemical amplification
    • Cantrell, C. A.; Stedman, D. H.; Wendel, G. J. Measurement of atmospheric peroxy radicals by chemical amplification. Anal. Chem. 1984, 56, 1496-1502.
    • (1984) Anal. Chem. , vol.56 , pp. 1496-1502
    • Cantrell, C.A.1    Stedman, D.H.2    Wendel, G.J.3
  • 11
    • 0000021262 scopus 로고    scopus 로고
    • Dual-inlet chemical amplifier for atmospheric peroxy radical measurements
    • Cantrell, C. A.; Shetter, R. E.; Calvert, J. G. Dual-inlet chemical amplifier for atmospheric peroxy radical measurements. Anal. Chem. 1996, 68, 4194-4199. (Pubitemid 126682599)
    • (1996) Analytical Chemistry , vol.68 , Issue.23 , pp. 4194-4199
    • Cantrell, C.A.1    Shelter, R.E.2    Calvert, J.G.3
  • 13
    • 0007706535 scopus 로고
    • Free radical detector for tropospheric measurement using chemical amplification
    • Hu, J.; Stedman, D. H. Free radical detector for tropospheric measurement using chemical amplification. Anal. Chem. 1994, 66, 3384-3393. (Pubitemid 24985364)
    • (1994) Analytical Chemistry , vol.66 , Issue.20 , pp. 3384-3393
    • Hu, J.1    Stedman, D.H.2
  • 16
    • 0033898766 scopus 로고    scopus 로고
    • Optimized operation and calibration procedures for radical amplifier-type detectors
    • Mihele, C. M.; Hastie, D. R. Optimized operation and calibration procedures for radical amplifier-type detectors. J. Atmos. Ocean. Technol. 2000, 17, 788-794.
    • (2000) J. Atmos. Ocean. Technol. , vol.17 , pp. 788-794
    • Mihele, C.M.1    Hastie, D.R.2
  • 17
    • 2042470137 scopus 로고    scopus 로고
    • Development of a measurement system of peroxy radicals using a chemical amplification/laser-induced fluorescence technique
    • Sadanaga, Y.; Matsumoto, J.; Sakurai, K.; Isozaki, R.; Kato, S.; Nomaguchi, T.; Bandow, H.; Kajii, Y. Development of a measurement system of peroxy radicals using a chemical amplification/laser-induced fluorescence technique. Rev. Sci. Instrum. 2004, 75, 864-872.
    • (2004) Rev. Sci. Instrum. , vol.75 , pp. 864-872
    • Sadanaga, Y.1    Matsumoto, J.2    Sakurai, K.3    Isozaki, R.4    Kato, S.5    Nomaguchi, T.6    Bandow, H.7    Kajii, Y.8
  • 22
    • 29144464162 scopus 로고
    • Cavity ring-down optical spectrometer for absorption measurements using pulsed laser sources
    • O'Keefe, A.; Deacon, D. A. G. Cavity ring-down optical spectrometer for absorption measurements using pulsed laser sources. Rev. Sci. Instrum. 1988, 59, 2544-2551.
    • (1988) Rev. Sci. Instrum. , vol.59 , pp. 2544-2551
    • O'Keefe, A.1    Deacon, D.A.G.2
  • 24
    • 0034306160 scopus 로고    scopus 로고
    • Detection of nitrous acid by cavity ring down spectroscopy
    • Wang, L. M.; Zhang, J. S. Detection of nitrous acid by cavity ring down spectroscopy. Environ. Sci. Technol. 2000, 34, 4221-4227.
    • (2000) Environ. Sci. Technol. , vol.34 , pp. 4221-4227
    • Wang, L.M.1    Zhang, J.S.2
  • 26
    • 36248967649 scopus 로고    scopus 로고
    • The complexities of air pollution regulation: The need for an integrated research and regulatory perspective
    • Nadadur, S. S.; Miller, C. A.; Hopke, P. K.; Gordon, T.; Vedal, S.; Vandenberg, J. J.; Costa, D. L. The complexities of air pollution regulation: The need for an integrated research and regulatory perspective. Toxicol. Sci. 2007, 100, 318-327.
    • (2007) Toxicol. Sci. , vol.100 , pp. 318-327
    • Nadadur, S.S.1    Miller, C.A.2    Hopke, P.K.3    Gordon, T.4    Vedal, S.5    Vandenberg, J.J.6    Costa, D.L.7
  • 27
    • 0022757746 scopus 로고
    • Sampling and determination of gas-phase hydrogen peroxide following removal of ozone by gas-phase reaction with nitric oxide
    • Tanner, R. L.; Markovits, G. Y.; Ferreri, E. M.; Kelly, T. J. Sampling and determination of gas-phase hydrogen peroxide following removal of ozone by gas-phase reaction with nitric oxide. Anal. Chem. 1986, 58, 1857-1865.
    • (1986) Anal. Chem. , vol.58 , pp. 1857-1865
    • Tanner, R.L.1    Markovits, G.Y.2    Ferreri, E.M.3    Kelly, T.J.4
  • 28
    • 12244305148 scopus 로고    scopus 로고
    • Detection of nitrogen dioxide by cavity attenuated phase shift spectroscopy
    • DOI 10.1021/ac048715y
    • Kebabian, P. L.; Herndon, S. C.; Freedman, A. Detection of nitrogen dioxide by cavity attenuated phase shift spectroscopy. Anal. Chem. 2005, 77, 724-728. (Pubitemid 40116860)
    • (2005) Analytical Chemistry , vol.77 , Issue.2 , pp. 724-728
    • Kebabian, P.L.1    Herndon, S.C.2    Freedman, A.3