메뉴 건너뛰기




Volumn 47, Issue 10, 2009, Pages 1103-1109

Time domain algorithm for accelerated determination of the first order moment of photo current fluctuations in high speed laser Doppler perfusion imaging

Author keywords

Blood perfusion measurement; CMOS; Laser Doppler perfusion flowmetry

Indexed keywords

BLOOD PERFUSION MEASUREMENT; CMOS; CURRENT FLUCTUATIONS; DATA TRANSPORT; FIRST MOMENTS; FIRST-ORDER; HIGH-SPEED LASER DOPPLER PERFUSION IMAGING; LASER DOPPLER PERFUSION IMAGING; LASER SPECKLE PATTERN; LASER-DOPPLER PERFUSION FLOWMETRY; LOSS OF ACCURACY; MEMORY USAGE; OPTICAL ARRAYS; REAL TIME; REAL TIME ACQUISITION; SPECTRAL MOMENTS; TIME DOMAIN; TIME-DOMAIN ALGORITHM; TISSUE PERFUSION;

EID: 70350315111     PISSN: 01400118     EISSN: None     Source Type: Journal    
DOI: 10.1007/s11517-009-0537-x     Document Type: Article
Times cited : (10)

References (34)
  • 1
    • 0026207688 scopus 로고
    • Bio-speckle phenomena and their application to the evaluation of blood flow
    • Aizu Y, Asakura T (1991) Bio-speckle phenomena and their application to the evaluation of blood flow. Opt Laser Technol 23(4):205-219
    • (1991) Opt Laser Technol , vol.23 , Issue.4 , pp. 205-219
    • Aizu, Y.1    Asakura, T.2
  • 2
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1:307-310
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 3
    • 0028791287 scopus 로고
    • Comparing methods of measurement: Why plotting difference against standard method is misleading
    • Bland JM, Altman DG (1995) Comparing methods of measurement: Why plotting difference against standard method is misleading. Lancet 346:1085-1087
    • (1995) Lancet , vol.346 , pp. 1085-1087
    • Bland, J.M.1    Altman, D.G.2
  • 4
    • 0019583049 scopus 로고
    • Model for laser Doppler measurements of blood flow in tissue
    • Bonner R, Nossal R (1981) Model for laser Doppler measurements of blood flow in tissue. Appl Opt 20(12):2097-2107
    • (1981) Appl Opt , vol.20 , Issue.12 , pp. 2097-2107
    • Bonner, R.1    Nossal, R.2
  • 5
    • 0037405441 scopus 로고    scopus 로고
    • Laser Doppler imaging of burn scars: A comparison of wavelength and scanning methods
    • Bray R, Forrester K, Leonard C, McArthur R, Tulip J, Lindsay R (2003) Laser Doppler imaging of burn scars: A comparison of wavelength and scanning methods. Burns 29(3):199-206
    • (2003) Burns , vol.29 , Issue.3 , pp. 199-206
    • Bray, R.1    Forrester, K.2    Leonard, C.3    McArthur, R.4    Tulip, J.5    Lindsay, R.6
  • 6
    • 0000099185 scopus 로고    scopus 로고
    • Laser Doppler and time-varying speckle: A reconciliation
    • Briers JD (1996) Laser Doppler and time-varying speckle: A reconciliation. J Opt Soc Am A 13(2):345-350
    • (1996) J Opt Soc Am A , vol.13 , Issue.2 , pp. 345-350
    • Briers, J.D.1
  • 7
    • 0035181228 scopus 로고    scopus 로고
    • Laser Doppler, speckle and related techniques for blood perfusion mapping and imaging
    • Briers JD (2001) Laser Doppler, speckle and related techniques for blood perfusion mapping and imaging. Physiol Meas 22:R35-R66
    • (2001) Physiol Meas , vol.22
    • Briers, J.D.1
  • 8
    • 0032735763 scopus 로고    scopus 로고
    • Capillary blood flow monitoring using laser speckle contrast analysis (LASCA)
    • Briers JD, Richards G, He XW (1999) Capillary blood flow monitoring using laser speckle contrast analysis (LASCA). J Biomed Opt 4(1):164-175
    • (1999) J Biomed Opt , vol.4 , Issue.1 , pp. 164-175
    • Briers, J.D.1    Richards, G.2    He, X.W.3
  • 9
    • 0141644107 scopus 로고    scopus 로고
    • Modified laser speckle imaging method with improved spatial resolution
    • Cheng H, Luo Q, Zeng S, Chen S, Cen J, Gong H (2003) Modified laser speckle imaging method with improved spatial resolution. J Biomed Opt 8(3):559-564
    • (2003) J Biomed Opt , vol.8 , Issue.3 , pp. 559-564
    • Cheng, H.1    Luo, Q.2    Zeng, S.3    Chen, S.4    Cen, J.5    Gong, H.6
  • 10
    • 34247564629 scopus 로고    scopus 로고
    • Diffusion model for iontophoresis measured by laser-Doppler perfusion flowmetry, applied to normal and preeclamptic pregnancies
    • de Mul FFM, Blaauw J, Aarnoudse JG, Smit AJ, Rakhorst G (2007) Diffusion model for iontophoresis measured by laser-Doppler perfusion flowmetry, applied to normal and preeclamptic pregnancies. J Biomed Opt 12(1):14032-1
    • (2007) J Biomed Opt , vol.12 , Issue.1 , pp. 14032-14041
    • de Mul, F.F.M.1    Blaauw, J.2    Aarnoudse, J.G.3    Smit, A.J.4    Rakhorst, G.5
  • 11
    • 67649968882 scopus 로고    scopus 로고
    • Review of laser speckle contrast techniques for visualizing tissue perfusion
    • Draijer MJ, Hondebrink E, van Leeuwen TG, Steenbergen W (2009a) Review of laser speckle contrast techniques for visualizing tissue perfusion. Lasers Med Sci 24(4):639-651
    • (2009) Lasers Med Sci , vol.24 , Issue.4 , pp. 639-651
    • Draijer, M.J.1    Hondebrink, E.2    van Leeuwen, T.G.3    Steenbergen, W.4
  • 12
    • 61549141422 scopus 로고    scopus 로고
    • The Twente optical perfusion camera: System overview and performance for real time laser Doppler perfusion imaging
    • Draijer MJ, Hondebrink E, van Leeuwen TG, Steenbergen W (2009b) The Twente optical perfusion camera: System overview and performance for real time laser Doppler perfusion imaging. Opt Express 17(5):3211-3225
    • (2009) Opt Express , vol.17 , Issue.5 , pp. 3211-3225
    • Draijer, M.J.1    Hondebrink, E.2    van Leeuwen, T.G.3    Steenbergen, W.4
  • 14
    • 0019579052 scopus 로고
    • Flow visualization by means of single-exposure speckle photography
    • Fercher AF, Briers JD (1981) Flow visualization by means of single-exposure speckle photography. Opt Commun 37(5):326-330
    • (1981) Opt Commun , vol.37 , Issue.5 , pp. 326-330
    • Fercher, A.F.1    Briers, J.D.2
  • 15
    • 0031282213 scopus 로고    scopus 로고
    • In vivo comparison of scanning technique and wavelength in laser doppler perfusion imaging: Measurement in knee ligaments of adult rabbits
    • Forrester K, Doschak M, Bray R (1997) In vivo comparison of scanning technique and wavelength in laser doppler perfusion imaging: Measurement in knee ligaments of adult rabbits. Med Biol Eng Comput 35:581-586
    • (1997) Med Biol Eng Comput , vol.35 , pp. 581-586
    • Forrester, K.1    Doschak, M.2    Bray, R.3
  • 16
    • 0036867463 scopus 로고    scopus 로고
    • Comparison of laser speckle and laser Doppler perfusion imaging: Measurement in human skin and rabbit articular tissue
    • Forrester KR, Stewart C, Tulip J, Leonard C, Bray RC (2002) Comparison of laser speckle and laser Doppler perfusion imaging: Measurement in human skin and rabbit articular tissue. Med Biol Eng Comput 40:687-697
    • (2002) Med Biol Eng Comput , vol.40 , pp. 687-697
    • Forrester, K.R.1    Stewart, C.2    Tulip, J.3    Leonard, C.4    Bray, R.C.5
  • 17
    • 0028166592 scopus 로고
    • Visualisation of retinal blood flow by laser speckle flowgraphy
    • Fujii H (1994) Visualisation of retinal blood flow by laser speckle flowgraphy. Med Biol Eng Comput 32:302-304
    • (1994) Med Biol Eng Comput , vol.32 , pp. 302-304
    • Fujii, H.1
  • 18
    • 0016462499 scopus 로고
    • McGraw-Hill College, New York
    • Hinze JO (1975) Turbulence. McGraw-Hill College, New York
    • (1975) Turbulence
    • Hinze, J.O.1
  • 19
    • 0033960785 scopus 로고    scopus 로고
    • Simplified model of laser Doppler signals during reactive hyperaemia
    • Humeau A, Saumet JL, Huillier JPL (2000) Simplified model of laser Doppler signals during reactive hyperaemia. Med Biol Eng Comput 38:80-87
    • (2000) Med Biol Eng Comput , vol.38 , pp. 80-87
    • Humeau, A.1    Saumet, J.L.2    Huillier, J.P.L.3
  • 21
    • 0037842891 scopus 로고    scopus 로고
    • Analysis and processing of laser Doppler perfusion monitoring signals recorded from the beating heart
    • Karlsson MGD, Casimir-Ahn H, Lönn U, Wårdell K (2003) Analysis and processing of laser Doppler perfusion monitoring signals recorded from the beating heart. Med Biol Eng Comput 41:255-262
    • (2003) Med Biol Eng Comput , vol.41 , pp. 255-262
    • Karlsson, M.G.D.1    Casimir-Ahn, H.2    Lönn, U.3    Wårdell, K.4
  • 22
    • 37549000554 scopus 로고    scopus 로고
    • A new method of screening for diabetic neuropathy using laser Doppler and photoplethysmography
    • Kim SW, Kim SC, Nam KC, Kang ES, Im JJ, Kim DW (2008) A new method of screening for diabetic neuropathy using laser Doppler and photoplethysmography. Med Biol Eng Comput 46:61-67
    • (2008) Med Biol Eng Comput , vol.46 , pp. 61-67
    • Kim, S.W.1    Kim, S.C.2    Nam, K.C.3    Kang, E.S.4    Im, J.J.5    Kim, D.W.6
  • 24
    • 0035990865 scopus 로고    scopus 로고
    • Effects of diode laser therapy on blood flow in axial pattern flaps in the rat model
    • Kubota J (2002) Effects of diode laser therapy on blood flow in axial pattern flaps in the rat model. Lasers Med Sci 17:146-153
    • (2002) Lasers Med Sci , vol.17 , pp. 146-153
    • Kubota, J.1
  • 25
    • 33745185777 scopus 로고    scopus 로고
    • Laser Doppler imaging of paediatric burns: Burn wound outcome can be predicted independent of clinical examination
    • La Hei E, Holland A, Martin H (2006) Laser Doppler imaging of paediatric burns: Burn wound outcome can be predicted independent of clinical examination. Burns 32:550-553
    • (2006) Burns , vol.32 , pp. 550-553
    • La Hei, E.1    Holland, A.2    Martin, H.3
  • 28
    • 51849145867 scopus 로고    scopus 로고
    • Review of methodological developments in laser Doppler flowmetry
    • [Epub ahead of print]
    • Rajan V, Varghese B, van Leeuwen TG, Steenbergen W (2008) Review of methodological developments in laser Doppler flowmetry. Lasers Med Sci 437:[Epub ahead of print]
    • (2008) Lasers Med Sci , pp. 437
    • Rajan, V.1    Varghese, B.2    van Leeuwen, T.G.3    Steenbergen, W.4
  • 29
    • 24144454179 scopus 로고    scopus 로고
    • High-speed laser Doppler perfusion imaging using an integrating CMOS image sensor
    • Serov A, Lasser T (2005) High-speed laser Doppler perfusion imaging using an integrating CMOS image sensor. Opt Express 13(17):6416-6428
    • (2005) Opt Express , vol.13 , Issue.17 , pp. 6416-6428
    • Serov, A.1    Lasser, T.2
  • 30
    • 0036507635 scopus 로고    scopus 로고
    • Laser Doppler perfusion imaging with a complimentary metal oxide semiconductor image sensor
    • Serov A, Steenbergen W, de Mul FFM (2002) Laser Doppler perfusion imaging with a complimentary metal oxide semiconductor image sensor. Opt Lett 27(5):300-302
    • (2002) Opt Lett , vol.27 , Issue.5 , pp. 300-302
    • Serov, A.1    Steenbergen, W.2    de Mul, F.F.M.3
  • 31
    • 21244498202 scopus 로고    scopus 로고
    • Full-field laser Doppler perfusion imaging and monitoring with an intelligent CMOS camera
    • Serov A, Steinacher B, Lasser T (2005) Full-field laser Doppler perfusion imaging and monitoring with an intelligent CMOS camera. Opt Express 13(10):3681-3689
    • (2005) Opt Express , vol.13 , Issue.10 , pp. 3681-3689
    • Serov, A.1    Steinacher, B.2    Lasser, T.3
  • 33
    • 23944507285 scopus 로고    scopus 로고
    • A comparison of two laser-based methods for determination of burn scar perfusion: Laser Doppler versus laser speckle imaging
    • Stewart CJ, Frank R, Forrester KR, Tulip J, Lindsay R, Bray RC (2005) A comparison of two laser-based methods for determination of burn scar perfusion: Laser Doppler versus laser speckle imaging. Burns 31:744-752
    • (2005) Burns , vol.31 , pp. 744-752
    • Stewart, C.J.1    Frank, R.2    Forrester, K.R.3    Tulip, J.4    Lindsay, R.5    Bray, R.C.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.