메뉴 건너뛰기




Volumn 45, Issue 3, 2009, Pages 297-306

Radiation-induced damage analysed by luminescence methods in retrospective dosimetry and emergency response

Author keywords

Dosimetry; Fortuitous dosimeters; Optically stimulated luminescence; Population triage; Thermoluminescence

Indexed keywords


EID: 70350304609     PISSN: 00212571     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (36)

References (46)
  • 2
    • 0027147634 scopus 로고
    • Retrospective accident dosimetry using environmental materials: the role of thermoluminescence
    • Haskell EH. Retrospective accident dosimetry using environmental materials: the role of thermoluminescence. Nucl Tracks Radiat Meas 1993;21:87-93.
    • (1993) Nucl Tracks Radiat Meas , vol.21 , pp. 87-93
    • Haskell, E.H.1
  • 3
    • 0031249425 scopus 로고    scopus 로고
    • Retrospective dosimetry with ceramics
    • Bailiff IK. Retrospective dosimetry with ceramics. Radiat Meas 1997;27:923-41.
    • (1997) Radiat Meas , vol.27 , pp. 923-941
    • Bailiff, I.K.1
  • 4
    • 33749662839 scopus 로고    scopus 로고
    • Luminescence dosimetry using building materials and personal objects
    • Göksu HY, Bailiff IK. Luminescence dosimetry using building materials and personal objects. Radiat Prot Dosim 2006; 119:413-20.
    • (2006) Radiat Prot Dosim , vol.119 , pp. 413-420
    • Göksu, H.Y.1    Bailiff, I.K.2
  • 5
    • 82055198415 scopus 로고    scopus 로고
    • International Commission on Radiation Units and measurements
    • ICRU; (Report 68). J ICRU
    • International Commission on Radiation Units and measurements. Retrospective assessment of exposures to ionising radiations. ICRU; 2002. (Report 68). J ICRU 2(2), p. 144.
    • (2002) Retrospective assessment of exposures to ionising radiations , vol.2 , Issue.2 , pp. 144
  • 7
    • 0030233556 scopus 로고    scopus 로고
    • An alternative technique for optically stimulated luminescence (OSL) experiment
    • Bulur E. An alternative technique for optically stimulated luminescence (OSL) experiment. Radiat Meas 1996;26:701-9.
    • (1996) Radiat Meas , vol.26 , pp. 701-709
    • Bulur, E.1
  • 10
    • 0342584238 scopus 로고    scopus 로고
    • Quartz OSL: effects of thermal treatment and their relevance to laboratory dating procedures
    • Wintle AG, Murray AS. Quartz OSL: Effects of thermal treatment and their relevance to laboratory dating procedures. Radiat Meas 2000;32:387-400.
    • (2000) Radiat Meas , vol.32 , pp. 387-400
    • Wintle, A.G.1    Murray, A.S.2
  • 11
    • 0007046530 scopus 로고
    • Dosimetry of atomic bomb radiation in Hiroshima by thermoluminescence of roof tiles
    • Higashimura T, Ichikawa Y, Sidei T. Dosimetry of atomic bomb radiation in Hiroshima by thermoluminescence of roof tiles. Science 1963;139:1284-5.
    • (1963) Science , vol.139 , pp. 1284-1285
    • Higashimura, T.1    Ichikawa, Y.2    Sidei, T.3
  • 12
    • 0003672349 scopus 로고
    • US Japan joint reassessment of atomic bomb radiation dosimetry in Hiroshima and Nagasaki, final report. DS86 Dosimetry System 1986
    • Roesch WC (Ed.) Vols 1 and 2. Hiroshima, Japan: The Radiation Effects Research Foundation
    • Roesch WC. US Japan joint reassessment of atomic bomb radiation dosimetry in Hiroshima and Nagasaki, final report. DS86 Dosimetry System 1986. In: Roesch WC (Ed.). Radiation measurements Vols 1 and 2. Hiroshima, Japan: The Radiation Effects Research Foundation; 1987.
    • (1987) Radiation measurements
    • Roesch, W.C.1
  • 13
    • 0028212267 scopus 로고
    • Thermoluminescence measurements of gamma-ray doses attributable to fallout from the Nevada Test Site using building bricks as natural dosemeters
    • Haskell EH, Bailiff IK, Kenner GH, Kaipa PL, Wrenn ME. Thermoluminescence measurements of gamma-ray doses attributable to fallout from the Nevada Test Site using building bricks as natural dosemeters. Health Phys 1994;66:380-91.
    • (1994) Health Phys , vol.66 , pp. 380-391
    • Haskell, E.H.1    Bailiff, I.K.2    Kenner, G.H.3    Kaipa, P.L.4    Wrenn, M.E.5
  • 16
    • 33645391553 scopus 로고    scopus 로고
    • Intercomparison of luminescence measurements of bricks from Dolon' Village: Experimental methodology and results of European Study Group
    • Göksu HY, Stepanenko, VF, Bailiff IK, Jungner H. intercomparison of luminescence measurements of bricks from Dolon' Village: Experimental methodology and results of European Study Group. J Rad Res 2006;47:(Suppl: A29- A37).
    • (2006) J Rad Res , vol.47 , Issue.SUPPL. A29-A37
    • Göksu, H.Y.1    Stepanenko, V.F.2    Bailiff, I.K.3    Jungner, H.4
  • 17
    • 0036387926 scopus 로고    scopus 로고
    • Investigations of thermoluminescence dosimetry in the Techa river floodplain: analysis of the new results
    • Bougrov NG, Baturin VA, Göksu HY, Degteva MO, Jacob P. Investigations of thermoluminescence dosimetry in the Techa river floodplain: analysis of the new results. Radiat Prot Dosim 2002;101:225-8.
    • (2002) Radiat Prot Dosim , vol.101 , pp. 225-228
    • Bougrov, N.G.1    Baturin, V.A.2    Göksu, H.Y.3    Degteva, M.O.4    Jacob, P.5
  • 20
    • 0342961835 scopus 로고    scopus 로고
    • Depth-dose distribution in bricks determined by thermoluminescence and by Monte-Carlo calculation for external γ-dose reconstruction
    • Göksu HY, Heide LM, Bougrov NG, Dalheimer AR, Meckbach R, Jacob P. Depth-dose distribution in bricks determined by thermoluminescence and by Monte-Carlo calculation for external γ-dose reconstruction. Appl Radiat Isot 1996;47:433-40.
    • (1996) Appl Radiat Isot , vol.47 , pp. 433-440
    • Göksu, H.Y.1    Heide, L.M.2    Bougrov, N.G.3    Dalheimer, A.R.4    Meckbach, R.5    Jacob, P.6
  • 21
    • 0141633028 scopus 로고    scopus 로고
    • Verification of external exposure assessment for the upper Techa riverside with luminescence measurements and Monte Carlo photon transport modeling
    • Taranenko V, Meckbach R, Degteva MO, Bougrov NG, Göksu Y, Vorobiova MI, Jacob P. Verification of external exposure assessment for the upper Techa riverside with luminescence measurements and Monte Carlo photon transport modeling. Radiat Environ Biophys 2003;42:17-26.
    • (2003) Radiat Environ Biophys , vol.42 , pp. 17-26
    • Taranenko, V.1    Meckbach, R.2    Degteva, M.O.3    Bougrov, N.G.4    Göksu, Y.5    Vorobiova, M.I.6    Jacob, P.7
  • 23
    • 0036387918 scopus 로고    scopus 로고
    • Optically Stimulated luminescence in retrospective dosimetry
    • Bøtter-Jensen L, Murray AS. Optically Stimulated luminescence in retrospective dosimetry. Radiat Prot Dosim 2002;101:309-14.
    • (2002) Radiat Prot Dosim , vol.101 , pp. 309-314
    • Bøtter-Jensen, L.1    Murray, A.S.2
  • 24
    • 43849097423 scopus 로고    scopus 로고
    • An assessment of cumulative external doses from Chernobyl fallout for a forested area in Russia using the optically stimulated luminescence form quartz inclusions in bricks
    • Ramzaev V, Bøtter-Jensen L, Thomsen KJ, Andersson KG and Murray AS. An assessment of cumulative external doses from Chernobyl fallout for a forested area in Russia using the optically stimulated luminescence form quartz inclusions in bricks. J Environ Radioact 2008;99:1154-64.
    • (2008) J Environ Radioact , vol.99 , pp. 1154-1164
    • Ramzaev, V.1    Bøtter-Jensen, L.2    Thomsen, K.J.3    Andersson, K.G.4    Murray, A.S.5
  • 26
    • 0036393023 scopus 로고    scopus 로고
    • Retrospective dosimetry: dose evaluation using unheated and heated quartz from a radioactive waste storage building
    • Jain M, Bøtter-Jensen L, Murray As, Jungner H. Retrospective dosimetry: dose evaluation using unheated and heated quartz from a radioactive waste storage building. Radiat Prot Dosim 2002;101:525-30.
    • (2002) Radiat Prot Dosim , vol.101 , pp. 525-530
    • Jain, M.1    Bøtter-Jensen, L.2    Murray, A.S.3    Jungner, H.4
  • 27
    • 0038643487 scopus 로고    scopus 로고
    • Variation with depth of dose distributions in single grains of quartz extracted from an irradiated concrete block
    • Thomson KJ, Jain M, Bøtter-Jensen L, Murray AS, Jungner H. Variation with depth of dose distributions in single grains of quartz extracted from an irradiated concrete block. Radiat Meas 2003;37:315-21.
    • (2003) Radiat Meas , vol.37 , pp. 315-321
    • Thomson, K.J.1    Jain, M.2    Bøtter-Jensen, L.3    Murray, A.S.4    Jungner, H.5
  • 28
    • 0037804560 scopus 로고    scopus 로고
    • New approaches to retrospective dosimtery using cementitous building materials
    • Göksu HY, Bailiff IK, Mikhailik VB. New approaches to retrospective dosimtery using cementitous building materials. Radiat Meas 2003;37:323-7.
    • (2003) Radiat Meas , vol.37 , pp. 323-327
    • Göksu, H.Y.1    Bailiff, I.K.2    Mikhailik, V.B.3
  • 29
    • 0036390740 scopus 로고    scopus 로고
    • Household and workplace chemicals as retrospective luminescence dosemeters
    • Thomson KJ, Bøtter-Jensen L, Murray AS. Household and workplace chemicals as retrospective luminescence dosemeters. Radiat Prot Dosim 2002;101:515-8.
    • (2002) Radiat Prot Dosim , vol.101 , pp. 515-518
    • Thomson, K.J.1    Bøtter-Jensen, L.2    Murray, A.S.3
  • 30
  • 32
    • 45049086316 scopus 로고    scopus 로고
    • Detection of gamma radiation absorbed by human tooth enamel using optically stimulated luminescence
    • Godfrey-Smith DI, Pass B. Detection of gamma radiation absorbed by human tooth enamel using optically stimulated luminescence. Health Phys 1997;72:1-5.
    • (1997) Health Phys , vol.72 , pp. 1-5
    • Godfrey-Smith, D.I.1    Pass, B.2
  • 33
    • 45049088315 scopus 로고    scopus 로고
    • Toward in vivo OSL dosimetry of human tooth enamel
    • Godrey-Smith DI. Toward in vivo OSL dosimetry of human tooth enamel. Radiat Meas 2008;43:854-8.
    • (2008) Radiat Meas , vol.43 , pp. 854-858
    • Godrey-Smith, D.I.1
  • 34
    • 0036390453 scopus 로고    scopus 로고
    • Luminescence characteristics of dental ceramics for retrospective dosimetry: a preliminary study
    • Bailiff IK, Correcher V, Delgado A, Göksu Y, Hübner S. Luminescence characteristics of dental ceramics for retrospective dosimetry: a preliminary study. Radiat Prot Dosim 2002;101:519-24.
    • (2002) Radiat Prot Dosim , vol.101 , pp. 519-524
    • Bailiff, I.K.1    Correcher, V.2    Delgado, A.3    Göksu, Y.4    Hübner, S.5
  • 35
    • 18244414634 scopus 로고    scopus 로고
    • Telephone chip cards as individual dosimeters
    • Göksu HY. Telephone chip cards as individual dosimeters. Radiat Meas 2003;37:617-20.
    • (2003) Radiat Meas , vol.37 , pp. 617-620
    • Göksu, H.Y.1
  • 37
    • 46549090031 scopus 로고    scopus 로고
    • Epoxy encapsulant as serendipitous dosimeters during radiological/nuclear events
    • Barkyoumb JH, Mathur VK. Epoxy encapsulant as serendipitous dosimeters during radiological/nuclear events. Radiat Meas 2008;43:841-4.
    • (2008) Radiat Meas , vol.43 , pp. 841-844
    • Barkyoumb, J.H.1    Mathur, V.K.2
  • 40
    • 70249148024 scopus 로고    scopus 로고
    • On the use of OSL of wire-bond chip card modules for retrospective and accident dosimetry
    • (in press.) doi:10.1016/j.radmeas.2009.02.016
    • Woda C, Spöttl T. On the use of OSL of wire-bond chip card modules for retrospective and accident dosimetry. Radiat Meas (in press.) doi:10.1016/j.radmeas.2009.02.016.
    • Radiat Meas
    • Woda, C.1    Spöttl, T.2
  • 42
    • 45249117719 scopus 로고    scopus 로고
    • Optically stimulated luminescence of electronic components for forensic, retrospective and accident dosimetry
    • Inrig EL, Godfrey-Smith DI, Khanna S. Optically stimulated luminescence of electronic components for forensic, retrospective and accident dosimetry. Radiat Meas 2008;43:726-30.
    • (2008) Radiat Meas , vol.43 , pp. 726-730
    • Inrig, E.L.1    Godfrey-Smith, D.I.2    Khanna, S.3
  • 43
    • 70249145471 scopus 로고    scopus 로고
    • Thermoluminescence dosimetry of electronic components from personal objects
    • (in press.). doi:10.1016/ j.radmeas.2009.02.003
    • Beerten K, Woda C, Vanhavere F. Thermoluminescence dosimetry of electronic components from personal objects. Radiat Meas; (in press.). doi:10.1016/ j.radmeas.2009.02.003.
    • Radiat Meas
    • Beerten, K.1    Woda, C.2    Vanhavere, F.3
  • 44
    • 85043048578 scopus 로고    scopus 로고
    • Radiation accident dosimetry on electronic components by OSL
    • accepted for publication
    • Bassinet C, Trompier F, Clairand I. Radiation accident dosimetry on electronic components by OSL. Health Phys (accepted for publication).
    • Health Phys
    • Bassinet, C.1    Trompier, F.2    Clairand, I.3
  • 45
    • 85043049916 scopus 로고    scopus 로고
    • Radiation accident dosimetry on glass by TL and EPR spectrometry
    • accepted fo publication
    • Bassinet C, Trompier F, Clairand I. Radiation accident dosimetry on glass by TL and EPR spectrometry. Health Phys (accepted fo publication).
    • Health Phys
    • Bassinet, C.1    Trompier, F.2    Clairand, I.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.