Volumn , Issue , 2009, Pages 112-115

ECoG recordings of a non-human primate using carbon nanotubes electrodes on a flexible polyimide implant

Author keywords

[No Author keywords available]

Indexed keywords

ELECTROCORTICOGRAM; FLEXIBLE MICROELECTRODE ARRAYS; FLEXIBLE POLYIMIDE; IN-VIVO; LONG TERM; NON-HUMAN PRIMATE; TIN ELECTRODES;

EID: 70350236505     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NER.2009.5109247     Document Type: Conference Paper
Times cited : (11)

References (16)
  • 2
    • 70350249804 scopus 로고    scopus 로고
    • A. B. Schwartz et al, Brain-Controlled Interfaces: Review Movement Restoration with Neural Prosthetics -. Neuron 2006
    • A. B. Schwartz et al, Brain-Controlled Interfaces: Review Movement Restoration with Neural Prosthetics -. Neuron 2006
  • 3
    • 0029023599 scopus 로고
    • Sensorimotor encoding by synchronous neural ensemble activity at multiple levels of the somatosensory system
    • Nicolelis, M.A. et al. (1995) Sensorimotor encoding by synchronous neural ensemble activity at multiple levels of the somatosensory system. Science 268, 1353-1358.
    • (1995) Science , vol.268 , pp. 1353-1358
    • Nicolelis, M.A.1
  • 6
    • 6344249527 scopus 로고    scopus 로고
    • A brain-computer interface using electrocorticographic signals in humans
    • E. C. Leuthardt, G. Schalk, J. R. Wolpaw, J. G. Ojemann, and D. W. Moran, "A brain-computer interface using electrocorticographic signals in humans," J. Neural Eng., vol. 1, pp. 63-71, 2004
    • (2004) J. Neural Eng , vol.1 , pp. 63-71
    • Leuthardt, E.C.1    Schalk, G.2    Wolpaw, J.R.3    Ojemann, J.G.4    Moran, D.W.5
  • 7
    • 0037526121 scopus 로고    scopus 로고
    • Spatial spectra of scalp EEG and EMG from awake humans
    • W. J. Freeman, M. D. Holmes, B. C. Burke, and S. Vanhatalo, "Spatial spectra of scalp EEG and EMG from awake humans," Clin. Neurophysiol. vol. 114, pp. 1053-1068, 2003
    • (2003) Clin. Neurophysiol , vol.114 , pp. 1053-1068
    • Freeman, W.J.1    Holmes, M.D.2    Burke, B.C.3    Vanhatalo, S.4
  • 8
    • 0038543295 scopus 로고    scopus 로고
    • Spatiotemporal patterns of beta desynchronization and gamma synchronization in corticographic data during selfpaced movement
    • G. Furtscheller, B. Graimann, J. E. Huggins, S. P. Levine, and L. A. Schuh, "Spatiotemporal patterns of beta desynchronization and gamma synchronization in corticographic data during selfpaced movement," Clin. Neurophysiol., vol. 114, pp. 1226-1236, 2003.
    • (2003) Clin. Neurophysiol , vol.114 , pp. 1226-1236
    • Furtscheller, G.1    Graimann, B.2    Huggins, J.E.3    Levine, S.P.4    Schuh, L.A.5
  • 9
    • 0037445482 scopus 로고    scopus 로고
    • Visual and electrical evoked response recorded from subdural electrodes implanted above the visual cortex in normal dogs under two methods of anesthesia
    • E. Margalit et al., "Visual and electrical evoked response recorded from subdural electrodes implanted above the visual cortex in normal dogs under two methods of anesthesia," J. Neurosci. Methods, vol. 123, pp. 129-137, 2003.
    • (2003) J. Neurosci. Methods , vol.123 , pp. 129-137
    • Margalit, E.1
  • 12
    • 33846783163 scopus 로고    scopus 로고
    • Electro-chemical and biological properties of carbon nanotubed multi-electrode arrays
    • T.Gabay et al.,"Electro-chemical and biological properties of carbon nanotubed multi-electrode arrays," Nanotechnology, vol. 18, no. 24, 2007.
    • (2007) Nanotechnology , vol.18 , Issue.24
    • Gabay, T.1
  • 13
    • 33749660040 scopus 로고    scopus 로고
    • K. Wang, H. A. Fishman, H. Dai, J. S. Harris, Neural Stimulation with a carbon nanotube microelectrode array, Nano. Lett., no. 9, pp. 2043-2048, 2006.
    • K. Wang, H. A. Fishman, H. Dai, J. S. Harris, "Neural Stimulation with a carbon nanotube microelectrode array," Nano. Lett., vol.-,no. 9, pp. 2043-2048, 2006.
  • 15
    • 19944412155 scopus 로고    scopus 로고
    • Towards a low-cost high-quality carbon-nanotube field-emission display
    • Dec
    • J. Dijon et al., "Towards a low-cost high-quality carbon-nanotube field-emission display," Journal of the Society for Information Display , vol. 12, no. 4, pp. 373-378, Dec. 2004
    • (2004) Journal of the Society for Information Display , vol.12 , Issue.4 , pp. 373-378
    • Dijon, J.1