메뉴 건너뛰기




Volumn 9, Issue 9, 2009, Pages 7097-7110

Photocurable polymers for ion selective field effect transistors. 20 years of applications

Author keywords

Chemical sensor; ISFET; Membrane; Photocurable; Polymers

Indexed keywords

FUTURE TRENDS; ION-SELECTIVE FIELD EFFECT TRANSISTORS; MEMBRANE FORMATION; PHOTOCURABLE; PHOTOCURABLE POLYMERS; PHOTOLITHOGRAPHIC PROCESS; SENSOR ENCAPSULATION; SENSOR MASS;

EID: 70350022535     PISSN: 14248220     EISSN: None     Source Type: Journal    
DOI: 10.3390/s90907097     Document Type: Review
Times cited : (24)

References (75)
  • 1
    • 34247185439 scopus 로고    scopus 로고
    • ISFET Based Sensors: Fundamentals and Applications
    • Grimes, C.A., Dickey, E.C., Pishko, M.V., Eds.; American Scientific Publishers: Stevenson Ranch, CA, USA
    • Jimenez, C.; Bratov, A.; Abramova, N.; Baldi, A. ISFET Based Sensors: Fundamentals and Applications. In Encyclopedia of Sensors; Grimes, C.A., Dickey, E.C., Pishko, M.V., Eds.; American Scientific Publishers: Stevenson Ranch, CA, USA, 2006; Volume 5, pp. 151-196.
    • (2006) Encyclopedia of Sensors , vol.5 , pp. 151-196
    • Jimenez, C.1    Bratov, A.2    Abramova, N.3    Baldi, A.4
  • 2
    • 0023675424 scopus 로고
    • Membrane design and photocuring encapsulation of flatpack based ion-sensitive field effect transistors
    • Moody, G.J.; Slater, M.J.M.; Thomas, J.D.R. Membrane design and photocuring encapsulation of flatpack based ion-sensitive field effect transistors. Analyst 1988, 113, 103-108.
    • (1988) Analyst , vol.113 , pp. 103-108
    • Moody, G.J.1    Slater, M.J.M.2    Thomas, J.D.R.3
  • 5
    • 0024032814 scopus 로고
    • Micromachined packaging for chemical microsensors
    • Smith, R.L.; Collins, S.D. Micromachined packaging for chemical microsensors. IEEE Trans. Electron. Devices 1988, 35, 787-792.
    • (1988) IEEE Trans. Electron. Devices , vol.35 , pp. 787-792
    • Smith, R.L.1    Collins, S.D.2
  • 6
    • 0023429851 scopus 로고
    • Flow-through ion-selective field-effect transistor
    • Sibbald, A.; Shaw, J.E.A. A Flow-through ion-selective field-effect transistor. Sens. Actuat. B 1987, 12, 297-300.
    • (1987) Sens. Actuat. B , vol.12 , pp. 297-300
    • Sibbald, A.1    Shaw, J.E.A.A.2
  • 9
    • 0029290625 scopus 로고
    • Photocurable polymers applied as encapsulating materials for ISFET production
    • Bratov, A.; Muñoz, J.; Dominguez, C.; Bartroli, J. Photocurable polymers applied as encapsulating materials for ISFET production. Sens. Actuat. B 1995, 25, 823-825.
    • (1995) Sens. Actuat. B , vol.25 , pp. 823-825
    • Bratov, A.1    Muñoz, J.2    Dominguez, C.3    Bartroli, J.4
  • 11
  • 12
    • 0030922105 scopus 로고    scopus 로고
    • A photo cured coated wire calcium ion selective electrode for use in flow injection potentiometry
    • Alexander, P.W.; Dimitrakopoulos, T.; Hibbert, D.B. A photo cured coated wire calcium ion selective electrode for use in flow injection potentiometry. Talanta 1997, 44, 1397-1405.
    • (1997) Talanta , vol.44 , pp. 1397-1405
    • Alexander, P.W.1    Dimitrakopoulos, T.2    Hibbert, D.B.3
  • 13
    • 0000631207 scopus 로고
    • Photocured polymers in ion-selective membranes. II: A calcium electrode for flow-injection analysis
    • Cardwell, T.J.; Cattrall, R.W.; Iles, P.J.; Hamilton, I.C. Photocured polymers in ion-selective membranes. II: A calcium electrode for flow-injection analysis. Anal. Chim. Acta 1985, 177, 239-242.
    • (1985) Anal. Chim. Acta , vol.177 , pp. 239-242
    • Cardwell, T.J.1    Cattrall, R.W.2    Iles, P.J.3    Hamilton, I.C.4
  • 14
    • 0006825448 scopus 로고
    • Photocured polymers in ion-selective membranes. 3. A potassium electrode for flow-injection analysis
    • Cardwell, T.J.; Cattrall, R.W.; Iles, P.J.; Hamilton, I.C. Photocured polymers in ion-selective membranes. 3. A potassium electrode for flow-injection analysis. Anal. Chim. Acta 1988, 204, 329-332.
    • (1988) Anal. Chim. Acta , vol.204 , pp. 329-332
    • Cardwell, T.J.1    Cattrall, R.W.2    Iles, P.J.3    Hamilton, I.C.4
  • 15
    • 0024562690 scopus 로고
    • Photocured polymers in ion-selective membranes. 4. An UV-laser cured membrane for potassium
    • Cardwell, T.J.; Cattrall, R.W.; Iles, P.J.; Hamilton, I.C. Photocured polymers in ion-selective membranes. 4. An UV-laser cured membrane for potassium. Anal. Chim. Acta 1989, 219, 135-140.
    • (1989) Anal. Chim. Acta , vol.219 , pp. 135-140
    • Cardwell, T.J.1    Cattrall, R.W.2    Iles, P.J.3    Hamilton, I.C.4
  • 16
    • 0030579573 scopus 로고    scopus 로고
    • Photocured polymers in ion-selectivee electrode membranes. Part 6: Photopolymerized lithium sensitive ion-selective electrodes for flow injection potentiometry
    • Farrell, J.R.; Iles, P.J.; Dimitrakopoulos, T. Photocured polymers in ion-selectivee electrode membranes. Part 6: Photopolymerized lithium sensitive ion-selective electrodes for flow injection potentiometry. Anal. Chim. Acta 1996, 335, 111-116.
    • (1996) Anal. Chim. Acta , vol.335 , pp. 111-116
    • Farrell, J.R.1    Iles, P.J.2    Dimitrakopoulos, T.3
  • 17
    • 0001618947 scopus 로고    scopus 로고
    • A six sensor array of coated-wire electrodes for use in a portable flow-injection analyzer
    • Alexander, P.W.; Dimitrakopoulos, T.; Hibbert, D.B. A six sensor array of coated-wire electrodes for use in a portable flow-injection analyzer. Electroanalysis 1998, 10, 707-712.
    • (1998) Electroanalysis , vol.10 , pp. 707-712
    • Alexander, P.W.1    Dimitrakopoulos, T.2    Hibbert, D.B.3
  • 19
    • 0000586531 scopus 로고
    • Photocurable polymer matrices for potassium-sensitive ion-selective electrode membranes
    • Bratov, A.; Abramova, N.; Muñoz, J.; Dominguez, C.; Alegret, S.; Bartroli, J. Photocurable polymer matrices for potassium-sensitive ion-selective electrode membranes. Anal. Chem. 1995, 67, 3589-3595.
    • (1995) Anal. Chem , vol.67 , pp. 3589-3595
    • Bratov, A.1    Abramova, N.2    Muñoz, J.3    Dominguez, C.4    Alegret, S.5    Bartroli, J.6
  • 21
    • 0033951465 scopus 로고    scopus 로고
    • ISFET-based calcium ion sensoor with photocured polyurethane membrane sutable for ionised calcium determination in milk
    • Bratov, A.; Abramova, N.; Dominguez, C.; Baldi, A. ISFET-based calcium ion sensoor with photocured polyurethane membrane sutable for ionised calcium determination in milk. Anal. Chim. Acta 2000, 408, 57-64.
    • (2000) Anal. Chim. Acta , vol.408 , pp. 57-64
    • Bratov, A.1    Abramova, N.2    Dominguez, C.3    Baldi, A.4
  • 22
    • 2442540926 scopus 로고    scopus 로고
    • Investigation of chloride sensitive ISFETs with different membrane compositions suitable for medical applications
    • Bratov, A.; Abramova, N.; Dominguez, C. Investigation of chloride sensitive ISFETs with different membrane compositions suitable for medical applications. Anal. Chim. Acta 2004, 514, 99-106.
    • (2004) Anal. Chim. Acta , vol.514 , pp. 99-106
    • Bratov, A.1    Abramova, N.2    Dominguez, C.3
  • 23
    • 67650102298 scopus 로고    scopus 로고
    • Integrated multi-sensor chip with photocured polymer membranes containing copolymerised plasticizer for direct pH, potassium, sodium and chloride ions determination in blood serum
    • DOI: TAL-D-08-02263R2 (in press)
    • Ipatov, A.; Abramova, N.; Bratov, A. Integrated multi-sensor chip with photocured polymer membranes containing copolymerised plasticizer for direct pH, potassium, sodium and chloride ions determination in blood serum. Talanta 2009, DOI: TAL-D-08-02263R2 (in press).
    • (2009) Talanta
    • Ipatov, A.1    Abramova, N.2    Bratov, A.3
  • 24
    • 0347875699 scopus 로고    scopus 로고
    • Photocurable carbonate-selective membranes for chemical sensors containing lipophilic additives
    • Levichev, S.; Smirnova, A.L.; Khitrova, V.L.; Lvova, L.B.; Bratov, A.; Vlasov, Y.G. Photocurable carbonate-selective membranes for chemical sensors containing lipophilic additives. Sens. Actuat. B 1997, 44, 397-401.
    • (1997) Sens. Actuat. B , vol.44 , pp. 397-401
    • Levichev, S.1    Smirnova, A.L.2    Khitrova, V.L.3    Lvova, L.B.4    Bratov, A.5    Vlasov, Y.G.6
  • 25
    • 0032120534 scopus 로고    scopus 로고
    • Potentiometric pH sensors based on urethane.acrylate photocurable polymer membranes
    • Puig-Lleixa, C.; Jimenez, C.; Fabregas, E.; Bartroli, J. Potentiometric pH sensors based on urethane.acrylate photocurable polymer membranes. Sens. Actuat. B 1998, 49, 211-217.
    • (1998) Sens. Actuat. B , vol.49 , pp. 211-217
    • Puig-Lleixa, C.1    Jimenez, C.2    Fabregas, E.3    Bartroli, J.4
  • 26
    • 0344629244 scopus 로고    scopus 로고
    • Development of a new photopolymerizable membrane for monochloroacetate sensitive potentiomtric sensors
    • Puig-Lleixa, C.; Ramíres-Garcia, S.; Jimenez, C.; Bartroli, J. Development of a new photopolymerizable membrane for monochloroacetate sensitive potentiomtric sensors. Anal. Chim. Acta 1999, 386, 13-19.
    • (1999) Anal. Chim. Acta , vol.386 , pp. 13-19
    • Puig-Lleixa, C.1    Ramíres-Garcia, S.2    Jimenez, C.3    Bartroli, J.4
  • 27
    • 0344223277 scopus 로고    scopus 로고
    • Polyurethane-acrylate photocurable membrane for ion-selective field-effect transistors based urea biosensor
    • Puig-Lleixa, C.; Jimenez, C.; Alonso, J.; Bartroli, J. Polyurethane-acrylate photocurable membrane for ion-selective field-effect transistors based urea biosensor. Anal. Chim. Acta 1999, 389, 179-188.
    • (1999) Anal. Chim. Acta , vol.389 , pp. 179-188
    • Puig-Lleixa, C.1    Jimenez, C.2    Alonso, J.3    Bartroli, J.4
  • 28
    • 0342468959 scopus 로고    scopus 로고
    • Acrylated polyurethane photopolymeric membrane for amperometric glucose biosensor construction
    • Puig-Lleixa, C.; Jimenez, C.; Bartroli, J. Acrylated polyurethane - photopolymeric membrane for amperometric glucose biosensor construction. Sens. Actuat. B 2001, 72, 56-62.
    • (2001) Sens. Actuat. B , vol.72 , pp. 56-62
    • Puig-Lleixa, C.1    Jimenez, C.2    Bartroli, J.3
  • 29
    • 0342902259 scopus 로고    scopus 로고
    • A new potentionmetric photocurable membrane selective to anionic surfactants
    • Sanchez, J.; del Valle, M. A new potentionmetric photocurable membrane selective to anionic surfactants. Electroanalysis 2001, 13, 471-476.
    • (2001) Electroanalysis , vol.13 , pp. 471-476
    • Sanchez, J.1    del Valle, M.2
  • 30
    • 0343196656 scopus 로고    scopus 로고
    • Use of photopolymerizable membranes based on polyacrylamide hydrogels for enzymatic microsensor construction
    • Jimenez, C.; Bartroli, J.; de Rooij, N.F.; Koudelka-Hep, M. Use of photopolymerizable membranes based on polyacrylamide hydrogels for enzymatic microsensor construction. Anal. Chim. Acta 1997, 351, 169-176.
    • (1997) Anal. Chim. Acta , vol.351 , pp. 169-176
    • Jimenez, C.1    Bartroli, J.2    de Rooij, N.F.3    Koudelka-Hep, M.4
  • 31
    • 0035979842 scopus 로고    scopus 로고
    • Cross-linked dodecyl acrylate microspheres: Novel matrices for plasticizer-free optical ion sensing
    • Peper, S.; Tsagkatakis, I.; Bakker, E. Cross-linked dodecyl acrylate microspheres: novel matrices for plasticizer-free optical ion sensing. Anal. Chim. Acta 2001, 442, 25-33.
    • (2001) Anal. Chim. Acta , vol.442 , pp. 25-33
    • Peper, S.1    Tsagkatakis, I.2    Bakker, E.3
  • 32
    • 0036684947 scopus 로고    scopus 로고
    • iX internal reference elements. I: Manufacturing and performance
    • Ciobanu, M.; Wilburn, J.P.; Buss, N.I.; Ditavong, P.; Lowy, D.A. Miniaturized reference electrodes based on Ag/AgiX internal reference elements. I: Manufacturing and performance. Electroanalysis 2002, 14, 989-997.
    • (2002) Electroanalysis , vol.14 , pp. 989-997
    • Ciobanu, M.1    Wilburn, J.P.2    Buss, N.I.3    Ditavong, P.4    Lowy, D.A.5
  • 33
    • 0042234023 scopus 로고    scopus 로고
    • Miniaturized sodium-selective sensors based on silicon back-side contact structure with novel self-plasticizing ion-selective membranes
    • Wydgladacz, K.; Durnas, M.; Parzuchowski, P.; Brzozka, Z.; Malinowska, E. Miniaturized sodium-selective sensors based on silicon back-side contact structure with novel self-plasticizing ion-selective membranes. Sens. Actuat. B 2003, 95, 366-372.
    • (2003) Sens. Actuat. B , vol.95 , pp. 366-372
    • Wydgladacz, K.1    Durnas, M.2    Parzuchowski, P.3    Brzozka, Z.4    Malinowska, E.5
  • 34
    • 0026013222 scopus 로고
    • Photolithographically pattenrnable nitrate-sensitive acrylate- based membrane
    • Dumschat, C.; Fromer, R.; Rautschek, H.; Muller, H.; Timpe, H.-J. Photolithographically pattenrnable nitrate-sensitive acrylate- based membrane. Anal. Chim. Acta 1991, 243, 179-182.
    • (1991) Anal. Chim. Acta , vol.243 , pp. 179-182
    • Dumschat, C.1    Fromer, R.2    Rautschek, H.3    Muller, H.4    Timpe, H.-J.5
  • 36
    • 0026173242 scopus 로고
    • An ISFET-based calcium sensor using photopolymerized polysiloxane membrane
    • van den Berg, A.; Verney-Norberg, E.; Grisel, A. An ISFET-based calcium sensor using photopolymerized polysiloxane membrane. Sens. Actuat. B 1991, 4, 235-238.
    • (1991) Sens. Actuat. B , vol.4 , pp. 235-238
    • van den Berg, A.1    Verney-Norberg, E.2    Grisel, A.3
  • 37
    • 0030597130 scopus 로고    scopus 로고
    • Durable nitrate- selectivee chemically modified field effect transistirs based on polysoloxine membranes
    • Antonisse, M.; Lugtenberg, R.; Egberink, R.; Engbersen, J.; Reinhoudt, D.N. Durable nitrate- selectivee chemically modified field effect transistirs based on polysoloxine membranes. Anal. Chim. Acta 1996, 332, 123-129.
    • (1996) Anal. Chim. Acta , vol.332 , pp. 123-129
    • Antonisse, M.1    Lugtenberg, R.2    Egberink, R.3    Engbersen, J.4    Reinhoudt, D.N.5
  • 40
    • 0028406703 scopus 로고
    • Vlasov, Yu.G. New photocurable composition for ISFET polymer membranes
    • Levichev, S.; Bratov, A.; Vlasov, Yu.G. New photocurable composition for ISFET polymer membranes. Sens. Actuat. B 1994, 18-19, 625-628.
    • (1994) Sens. Actuat. B , vol.18-19 , pp. 625-628
    • Levichev, S.1    Bratov, A.2
  • 41
    • 0345778919 scopus 로고    scopus 로고
    • Lohg-lived potentiometric sensors with poly(vinilchloride) and photopolymerized polyacrylate matrix anion sensitive membranes, applied on field effect transistors and silver coated ceramic substrate
    • Kolytcheva, N.V.; Petrukhin, O.M.; Filipjeva, N.V.; Muller, H. Lohg-lived potentiometric sensors with poly(vinilchloride) and photopolymerized polyacrylate matrix anion sensitive membranes, applied on field effect transistors and silver coated ceramic substrate. Sens. Actuat. B 1998, 48, 491-500.
    • (1998) Sens. Actuat. B , vol.48 , pp. 491-500
    • Kolytcheva, N.V.1    Petrukhin, O.M.2    Filipjeva, N.V.3    Muller, H.4
  • 42
    • 0033190211 scopus 로고    scopus 로고
    • Influence of the organic matrix on the properties of membrane coated ion sensor field-effect transistord
    • Kolytcheva, N.V.; Muller, H.; Marstalrz, J. Influence of the organic matrix on the properties of membrane coated ion sensor field-effect transistord. Sens. Actuat. B 1999, 58, 456-463.
    • (1999) Sens. Actuat. B , vol.58 , pp. 456-463
    • Kolytcheva, N.V.1    Muller, H.2    Marstalrz, J.3
  • 43
    • 0002797481 scopus 로고    scopus 로고
    • Producing self-plasticizing ion-selective membranes
    • Heng, L.Y.; Hall, E.A.H. Producing self-plasticizing ion-selective membranes. Anal. Chem. 2000, 72, 42-51.
    • (2000) Anal. Chem. , vol.72 , pp. 42-51
    • Heng, L.Y.1    Hall, E.A.H.2
  • 45
    • 0345276682 scopus 로고    scopus 로고
    • Plasticizer-free microspheres for ionophore-based sensing and extraction based on a methyl methacrylate-decyl methacrylate copolymer matrix
    • Peper, S.; Ceresa, A.; Qin, Y.; Bakker, E. Plasticizer-free microspheres for ionophore-based sensing and extraction based on a methyl methacrylate-decyl methacrylate copolymer matrix. Anal. Chim. Acta 2003, 500, 127-136.
    • (2003) Anal. Chim. Acta , vol.500 , pp. 127-136
    • Peper, S.1    Ceresa, A.2    Qin, Y.3    Bakker, E.4
  • 46
    • 11144271368 scopus 로고    scopus 로고
    • Copolymers from oligosiloxane methacrylte as a plasticizer-free membrane matrix for ion-selective sensors
    • Edelmann, K.; Reiche, A.; Sander, B.; Mastalerz, J.; Muller, H. Copolymers from oligosiloxane methacrylte as a plasticizer-free membrane matrix for ion-selective sensors. Polymer 2005, 46, 407-417.
    • (2005) Polymer , vol.46 , pp. 407-417
    • Edelmann, K.1    Reiche, A.2    Sander, B.3    Mastalerz, J.4    Muller, H.5
  • 49
    • 4043138581 scopus 로고    scopus 로고
    • Optimisation of the composition of a screen-printed acrylate polymer enzyme layer with respect to an improved selectivity and stability of enzyme electrodes
    • Mersal, G.A.M.; Khodari, M.; Bilitewski, U. Optimisation of the composition of a screen-printed acrylate polymer enzyme layer with respect to an improved selectivity and stability of enzyme electrodes. Biosen. Bioelectron. 2004, 20, 305-314.
    • (2004) Biosen. Bioelectron , vol.20 , pp. 305-314
    • Mersal, G.A.M.1    Khodari, M.2    Bilitewski, U.3
  • 50
    • 20344403729 scopus 로고    scopus 로고
    • Immobilization of urease and cholinesterase on the surface of semiconductor transducer for the development of light-addressable potentiometric sensors
    • Mourzina, I.G.; Yoshinobu, T.; Ermolenko, Y.E.; Vlasov, Y.G.; Schoning, M.J.; Iwasaki, H. Immobilization of urease and cholinesterase on the surface of semiconductor transducer for the development of light-addressable potentiometric sensors. Microchim. Acta 2004, 144, 41-50.
    • (2004) Microchim. Acta , vol.144 , pp. 41-50
    • Mourzina, I.G.1    Yoshinobu, T.2    Ermolenko, Y.E.3    Vlasov, Y.G.4    Schoning, M.J.5    Iwasaki, H.6
  • 51
    • 0000318433 scopus 로고
    • Ptotopolymerisation of ion-selecttive membranes onto silicon nitride surfaces for ISFET fabrication
    • Tietje-Girault, J.; MacInnes, I.; Schroder, M.; Tennat, G.; Girault, H.H. Ptotopolymerisation of ion-selecttive membranes onto silicon nitride surfaces for ISFET fabrication. Electrochim. Acta 1990, 35, 777-783.
    • (1990) Electrochim. Acta , vol.35 , pp. 777-783
    • Tietje-Girault, J.1    Macinnes, I.2    Schroder, M.3    Tennat, G.4    Girault, H.H.5
  • 52
    • 0022026038 scopus 로고
    • Integrated enzyme F.E.T.S. for simultaneous detections of urea and glucose
    • Miyahara, Y.; Moriizumi, T.; Ichimura, K. Integrated enzyme FETS for simultaneous detections of urea and glucose. Sens. Actuat. B 1985, 7, 1-10.
    • (1985) Sens. Actuat. B , vol.7 , pp. 1-10
    • Miyahara, Y.1    Moriizumi, T.2    Ichimura, K.3
  • 53
    • 0031164717 scopus 로고    scopus 로고
    • ISFET glucose and sucrose sensors by using platinum electrode and photo-crosslinkable polymers
    • Sohn, B.; Cho, B.; Kim, C.; Kwon, D. ISFET glucose and sucrose sensors by using platinum electrode and photo-crosslinkable polymers. Sens. Actuat. B 1997, 41, 7-11.
    • (1997) Sens. Actuat. B , vol.41 , pp. 7-11
    • Sohn, B.1    Cho, B.2    Kim, C.3    Kwon, D.4
  • 54
    • 0141956404 scopus 로고    scopus 로고
    • A novel urea sensitive biosensor with extended dynamic range based on recombinant urease and ISFETs
    • Soldatkin, A.P.; Montoriol, J.; Sant, W.; Martelet, C.; Jaffrezic-Renault, N. A novel urea sensitive biosensor with extended dynamic range based on recombinant urease and ISFETs. Biosen. Bioelectron. 2003, 19, 131-135.
    • (2003) Biosen. Bioelectron , vol.19 , pp. 131-135
    • Soldatkin, A.P.1    Montoriol, J.2    Sant, W.3    Martelet, C.4    Jaffrezic-Renault, N.5
  • 56
    • 0343081373 scopus 로고    scopus 로고
    • Sensitive detection of pesticide using ENFET with enzymes immobilized by cross-linking and entrapment method
    • Wan, K.; Chovelon, J.M.; Jaffrezic-Renault, N.; Soldatkin, A.P. Sensitive detection of pesticide using ENFET with enzymes immobilized by cross-linking and entrapment method. Sens. Actuat. B 1999, 58, 399-408.
    • (1999) Sens. Actuat. B , vol.58 , pp. 399-408
    • Wan, K.1    Chovelon, J.M.2    Jaffrezic-Renault, N.3    Soldatkin, A.P.4
  • 58
    • 41549149657 scopus 로고    scopus 로고
    • Integrated multi-sensor chip with sequential injection technique as a base for electronic tongue devices
    • Ipatov, A.; Abramova, N.; Bratov, A.; Dominguez, C. Integrated multi-sensor chip with sequential injection technique as a base for electronic tongue devices. Sens. Actuat. B 2008, 131, 48-52.
    • (2008) Sens. Actuat. B , vol.131 , pp. 48-52
    • Ipatov, A.1    Abramova, N.2    Bratov, A.3    Dominguez, C.4
  • 59
    • 0027325714 scopus 로고
    • Lipophilic and immobilized anionic additives in solvent polymeric membranes of cation-selective chemical sensors
    • Rosatzin, T.; Bakker, E.; Suzuki, K.; Simon, W. Lipophilic and immobilized anionic additives in solvent polymeric membranes of cation-selective chemical sensors. Anal. Chim. Acta 1993, 280, 197-208.
    • (1993) Anal. Chim. Acta , vol.280 , pp. 197-208
    • Rosatzin, T.1    Bakker, E.2    Suzuki, K.3    Simon, W.4
  • 60
    • 70350036217 scopus 로고    scopus 로고
    • Ion Selective Field Effect Transistors with fotocurable membrane selective for K and NH4 ions
    • St.Petersburg University, Saint Petersburg, Russia
    • Abramova, N. Ion Selective Field Effect Transistors with fotocurable membrane selective for K and NH4 ions, PhD dissertation, St.Petersburg University, Saint Petersburg, Russia, 1998.
    • (1998) PhD dissertation
    • Abramova, N.1
  • 62
    • 0024606505 scopus 로고
    • Photopolimerization of plastisizers in ion- sensitive membranes of solid-state sensors
    • Harrison, D.J.; Teclemariam, A.; Cunningham, L.L. Photopolimerization of plastisizers in ion- sensitive membranes of solid-state sensors. Anal. Chem. 1989, 61, 246-251.
    • (1989) Anal. Chem , vol.61 , pp. 246-251
    • Harrison, D.J.1    Teclemariam, A.2    Cunningham, L.L.3
  • 63
    • 0002849122 scopus 로고    scopus 로고
    • Methacrylic-acrylic polymers in ion-selective membrane: Achieving the rightr polymer recipe
    • Heng, L.Y.; Hall, E.A.H. Methacrylic-acrylic polymers in ion-selective membrane: achieving the rightr polymer recipe. Anal. Chim. Acta 2000, 403, 77-89.
    • (2000) Anal. Chim. Acta , vol.403 , pp. 77-89
    • Heng, L.Y.1    Hall, E.A.H.2
  • 64
    • 1842721095 scopus 로고    scopus 로고
    • Taking the plasticizer out of methacrylic-acrylic membranes for K-selective electrodes
    • Heng, L.Y.; Hall, E.A.H. Taking the plasticizer out of methacrylic-acrylic membranes for K-selective electrodes. Electroanalysis 2000, 12, 187-193.
    • (2000) Electroanalysis , vol.12 , pp. 187-193
    • Heng, L.Y.1    Hall, E.A.H.2
  • 65
    • 0036855184 scopus 로고    scopus 로고
    • Plasticizer-free polymer membrane ion-selective electrodes containig a methacrylic copolymer matrix
    • Qin, Y.; Peper, S.; Bakker, E. Plasticizer-free polymer membrane ion-selective electrodes containig a methacrylic copolymer matrix. Electroanalysis 2002, 14, 1375-1381.
    • (2002) Electroanalysis , vol.14 , pp. 1375-1381
    • Qin, Y.1    Peper, S.2    Bakker, E.3
  • 68
    • 0037211184 scopus 로고    scopus 로고
    • Thirty years of ISFETOLOGY What happened in the past 30 years and what may happen in the next 30 years
    • Bergveld, P. Thirty years of ISFETOLOGY What happened in the past 30 years and what may happen in the next 30 years. Sens. Actuat. B 2003, 88, 1-20.
    • (2003) Sens. Actuat. B , vol.88 , pp. 1-20
    • Bergveld, P.1
  • 69
    • 84876605651 scopus 로고    scopus 로고
    • Available Online, (accessed on August 31, 2009)
    • Alpha M.O.S. Available Online: http://www.alpha-mos.com/technology/instruments.html (accessed on August 31, 2009).
    • Alpha, M.O.S.1
  • 70
    • 34748826106 scopus 로고    scopus 로고
    • Sensors arrays for liquid sensing- electronic tongue systems
    • Ciosek, P.; Wróblewski, W. Sensors arrays for liquid sensing- electronic tongue systems. Analyst 2007, 132, 963-978.
    • (2007) Analyst , vol.132 , pp. 963-978
    • Ciosek, P.1    Wróblewski, W.2
  • 72
    • 33646797444 scopus 로고    scopus 로고
    • Multi-sensor array used as an "electronic tongue" for mineral water analysis
    • Moreno, L.; Merlos, A.; Abramova, N.; Jimenez, C.; Bratov, A. Multi-sensor array used as an "electronic tongue" for mineral water analysis. Sens. Actuat. B 2006, 116, 130-134.
    • (2006) Sens. Actuat. B , vol.116 , pp. 130-134
    • Moreno, L.1    Merlos, A.2    Abramova, N.3    Jimenez, C.4    Bratov, A.5
  • 73
    • 54849404083 scopus 로고    scopus 로고
    • Autocalibration technique based on SIA and integrated multisensor chip
    • Ipatov, A.; Abramova, N.; Bratov, A. Autocalibration technique based on SIA and integrated multisensor chip. Talanta 2008, 77, 581-586.
    • (2008) Talanta , vol.77 , pp. 581-586
    • Ipatov, A.1    Abramova, N.2    Bratov, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.