메뉴 건너뛰기




Volumn 10, Issue 5, 2009, Pages 592-596

The effect of syringe size on reliability and safety of low-flow infusions

Author keywords

Clinical nursing research; Intravenous infusions; Medication errors; Methodologic studies; Nursing methodology research; Pediatric intensive care units

Indexed keywords

ALARM MONITOR; ARTICLE; FLOW RATE; INFUSION PUMP; INFUSION RATE; INTENSIVE CARE UNIT; OCCLUSION; PRIORITY JOURNAL; RELIABILITY; SAFETY; STEADY STATE; SYRINGE; TUBE FLOW; VALIDATION STUDY;

EID: 70349902553     PISSN: 15297535     EISSN: None     Source Type: Journal    
DOI: 10.1097/PCC.0b013e3181a0e2e9     Document Type: Article
Times cited : (19)

References (10)
  • 1
    • 0003413171 scopus 로고    scopus 로고
    • Kohn LT, Corrigan JM, Donaldson MS (Eds). Washington, DC, Institute of Medicine
    • Kohn LT, Corrigan JM, Donaldson MS (Eds). To Err Is Human: Building a Safer Health System. Washington, DC, Institute of Medicine, 1999
    • (1999) To Err Is Human: Building a Safer Health System
  • 2
    • 0042131572 scopus 로고    scopus 로고
    • Prevention of Medication Errors in the Pediatric Inpatient Setting
    • American Academy of Pediatrics Committee on Drugs and Committee on Hospital Care
    • American Academy of Pediatrics Committee on Drugs and Committee on Hospital Care: Prevention of Medication Errors in the Pediatric Inpatient Setting. Pediatrics 2003; 112: 431-436
    • (2003) Pediatrics , vol.112 , pp. 431-436
  • 3
    • 16244365196 scopus 로고    scopus 로고
    • Syringe pumps take too long to give occlusion alarm
    • DOI 10.1111/j.1460-9592.2005.01436.x
    • Dönmez A, Araz C, Kayhan Z: Syringe pumps take too long to give occlusion alarm. Paediatr Anaesth 2005; 15:293-296 (Pubitemid 40462803)
    • (2005) Paediatric Anaesthesia , vol.15 , Issue.4 , pp. 293-296
    • Donmez, A.1    Araz, C.2    Kayhan, Z.3
  • 4
    • 85047699866 scopus 로고    scopus 로고
    • Flow rate, syringe size and architecture are critical to start-up performance of syringe pumps
    • DOI 10.1017/S0265021506002328, PII S0265021506002328
    • Neff SB, Neff TA, Gerber S, et al: Flow rate, syringe size and architecture are critical to start-up performance of syringe pumps. Eur J Anaesthesiol 2007; 24:602-608 (Pubitemid 47289764)
    • (2007) European Journal of Anaesthesiology , vol.24 , Issue.7 , pp. 602-608
    • Neff, S.B.1    Neff, T.A.2    Gerber, S.3    Weiss, M.M.4
  • 5
    • 0026597166 scopus 로고
    • The accuracy and variability of bolus injections with different sized syringes
    • Thobani SU, Steward DJ: The accuracy and variability of bolus injections with different sized syringes. Can J Anesth 1992; 39: 198-201
    • (1992) Can J Anesth , vol.39 , pp. 198-201
    • Thobani, S.U.1    Steward, D.J.2
  • 6
    • 0033735621 scopus 로고    scopus 로고
    • Syringe size and flow rate affect drug delivery from syringe pumps
    • Weiss M, Hug MI, Neff T, et al: Syringe size and flow rate affect drug delivery from syringe pumps. Can J Anesth 2000; 47: 1031-1035 (Pubitemid 30803273)
    • (2000) Canadian Journal of Anesthesia , vol.47 , Issue.10 , pp. 1031-1035
    • Weiss, M.1    Hug, M.I.2    Neff, T.3    Fischer, J.4
  • 7
    • 0033646088 scopus 로고    scopus 로고
    • Impact of infusion line compliance on syringe pump performance
    • Weiss M, Neff T, Gerber A, et al: Impact of infusion line compliance on syringe pump performance. Paediatr Anaesth 2000; 10: 595-599
    • (2000) Paediatr Anaesth , vol.10 , pp. 595-599
    • Weiss, M.1    Neff, T.2    Gerber, A.3
  • 8
    • 0033058033 scopus 로고    scopus 로고
    • The effect of syringe size on the performance of an infusion pump
    • DOI 10.1046/j.1460-9592.1999.00402.x
    • Kim DW, Steward DJ: The effect of syringe size on the performance of an infusion pump. Paediatr Anaesth 1999; 9:335-337 (Pubitemid 29307512)
    • (1999) Paediatric Anaesthesia , vol.9 , Issue.4 , pp. 335-337
    • Kim, D.W.1    Steward, D.J.2
  • 9
    • 85031345144 scopus 로고    scopus 로고
    • Available at: Accessed August 1, 2008
    • The National Coordinating Council for Medication Error Reporting and Prevention: About Medication Errors: Definition [online article]. Available at: http://www.nccmerp. org/aboutMedErrors.html. Accessed August 1, 2008
    • About Medication Errors: Definition [Online Article]
  • 10
    • 0029131840 scopus 로고
    • Fluctuations in syringe-pump infusions: Association with blood pressure variations in infants
    • Capes DF, Dunster KR, Sunderland VB, et al: Fluctuations in syringe-pump infusions: Association with blood pressure variations in infants. Am J Health Syst Pharm 1995; 52: 1646-1653
    • (1995) Am J Health Syst Pharm , vol.52 , pp. 1646-1653
    • Capes, D.F.1    Dunster, K.R.2    Sunderland, V.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.