메뉴 건너뛰기




Volumn 247, Issue 11, 2009, Pages 1539-1545

Comparison of different excimer laser ablation frequencies (50, 200, and 500 Hz)

Author keywords

Ablation frequency; Excimer; LASIK; PRK

Indexed keywords

ANIMAL CELL; ANIMAL TISSUE; ARTICLE; CELL COUNT; CELL DENSITY; CELL STRUCTURE; CELL ULTRASTRUCTURE; CELLULAR DISTRIBUTION; CONTROLLED STUDY; CORNEA; CORNEA CELL; CORNEA ENDOTHELIUM; ENDOTHELIUM CELL; EXCIMER LASER; LASER SURGERY; MICROSCOPY; NONHUMAN; POSTOPERATIVE PERIOD; PREOPERATIVE PERIOD; PRIORITY JOURNAL; SWINE; TRANSMISSION ELECTRON MICROSCOPY;

EID: 70349857782     PISSN: 0721832X     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00417-009-1102-x     Document Type: Article
Times cited : (17)

References (16)
  • 2
    • 0028946783 scopus 로고
    • The effects of ablation diameter on the outcome of excimer laser photorefractive keratectomy. A prospective, randomized, double-blind study
    • O'Brart DP, Corbett MC, Lohmann CP, Kerr Muir MG, Marshall J (1995) The effects of ablation diameter on the outcome of excimer laser photorefractive keratectomy. A prospective, randomized, double-blind study. Arch Ophthalmol 113:438-443
    • (1995) Arch Ophthalmol , vol.113 , pp. 438-443
    • O'Brart, D.P.1    Corbett, M.C.2    Lohmann, C.P.3    Kerr Muir, M.G.4    Marshall, J.5
  • 3
    • 0027416253 scopus 로고
    • Myopic keratomileusis with the excimer laser: One-year follow up
    • Buratto L, Ferrari M, Genisi C (1993) Myopic keratomileusis with the excimer laser: One-year follow up. Refract Corneal Surg 9:12-19
    • (1993) Refract Corneal Surg , vol.9 , pp. 12-19
    • Buratto, L.1    Ferrari, M.2    Genisi, C.3
  • 4
    • 0026344939 scopus 로고
    • Photorefractive keratectomy with an argon fluoride excimer laser: A clinical study
    • Gartry DS, Kerr Muir MG, Marshall J (1991) Photorefractive keratectomy with an argon fluoride excimer laser: A clinical study. Refract Corneal Surg 7:420-435
    • (1991) Refract Corneal Surg , vol.7 , pp. 420-435
    • Gartry, D.S.1    Kerr Muir, M.G.2    Marshall, J.3
  • 5
    • 0029086877 scopus 로고
    • Current evaluation of myopia correction with the excimer laser
    • Seiler T (1995) Current evaluation of myopia correction with the excimer laser. Ophthalmologe 92:379-384
    • (1995) Ophthalmologe , vol.92 , pp. 379-384
    • Seiler, T.1
  • 6
    • 13844317415 scopus 로고    scopus 로고
    • Femtosecond laser versus mechanical keratome flaps in wavefront-guided laser in situ keratomileusis: Prospective contralateral eye study
    • doi: 10.1016/j.jcrs.2004.09.046
    • Durrie DS, Kezirian GM (2005) Femtosecond laser versus mechanical keratome flaps in wavefront-guided laser in situ keratomileusis: prospective contralateral eye study. J Cataract Refract Surg 31:120-126. doi: 10.1016/j.jcrs.2004.09.046
    • (2005) J Cataract Refract Surg , vol.31 , pp. 120-126
    • Durrie, D.S.1    Kezirian, G.M.2
  • 7
    • 0344851856 scopus 로고    scopus 로고
    • First 100 CustomCornea commercial eyes
    • Durrie DS (2003) First 100 CustomCornea commercial eyes. J Refract Surg 19:S687-S690
    • (2003) J Refract Surg , vol.19
    • Durrie, D.S.1
  • 8
    • 0035112069 scopus 로고    scopus 로고
    • Clinical results of wavefront-guided laser in situ keratomileusis 3 months after surgery
    • doi: 10.1016/S0886-3350(00)00827-0
    • Mrochen M, Kaemmerer M, Seiler T (2001) Clinical results of wavefront-guided laser in situ keratomileusis 3 months after surgery. J Cataract Refract Surg 27:201-207. doi: 10.1016/S0886-3350(00)00827-0
    • (2001) J Cataract Refract Surg , vol.27 , pp. 201-207
    • Mrochen, M.1    Kaemmerer, M.2    Seiler, T.3
  • 9
    • 55849083100 scopus 로고    scopus 로고
    • Topographically guided laser in situ keratomileusis for myopia using a customized aspherical treatment zone
    • doi: 10.1016/j.jcrs.2008.07.021
    • Dougherty PJ, Waring G III, Chayet A, Fischer J, Fant B, Bains HS (2008) Topographically guided laser in situ keratomileusis for myopia using a customized aspherical treatment zone. J Cataract Refract Surg 34:1862-1871. doi: 10.1016/j.jcrs.2008.07.021
    • (2008) J Cataract Refract Surg , vol.34 , pp. 1862-1871
    • Dougherty, P.J.1    Waring III, G.2    Chayet, A.3    Fischer, J.4    Fant, B.5    Bains, H.S.6
  • 10
    • 0038036305 scopus 로고    scopus 로고
    • Topographically guided ablations for the correction of irregular astigmatism after corneal surgery
    • Guell JL, Velasco F (2003) Topographically guided ablations for the correction of irregular astigmatism after corneal surgery. Int Ophthalmol Clin 43:111-128
    • (2003) Int. Ophthalmol Clin , vol.43 , pp. 111-128
    • Guell, J.L.1    Velasco, F.2
  • 11
    • 0018775237 scopus 로고
    • Picrosirius staining plus polarization microscopy, a specific method for collagen detection in tissue sections
    • doi: 10.1007/BF01002772
    • Junqueira LC, Bignolas G, Brentani RR (1979) Picrosirius staining plus polarization microscopy, a specific method for collagen detection in tissue sections. Histochem J 11:447-455. doi: 10.1007/BF01002772
    • (1979) Histochem J , vol.11 , pp. 447-455
    • Junqueira, L.C.1    Bignolas, G.2    Brentani, R.R.3
  • 12
    • 0015716564 scopus 로고
    • Polarization microscopic studies of connective tissue stained with Picro-sirius Red FBA
    • Puchtler H, Waldrop FS, Valentine LS (1973) Polarization microscopic studies of connective tissue stained with Picro-sirius Red FBA. Beitr Pathol 150:174-187
    • (1973) Beitr Pathol , vol.150 , pp. 174-187
    • Puchtler, H.1    Waldrop, F.S.2    Valentine, L.S.3
  • 13
    • 33644836123 scopus 로고    scopus 로고
    • Continuous measurement of corneal dehydration with online optical coherence pachymetry
    • doi: 10.1097/01.ico.0000176610.50461.77
    • Aurich H, Wirbelauer C, Jaroszewski J, Hartmann C, Pham DT (2006) Continuous measurement of corneal dehydration with online optical coherence pachymetry. Cornea 25:182-184. doi: 10.1097/ 01.ico.0000176610.50461.77
    • (2006) Cornea , vol.25 , pp. 182-184
    • Aurich, H.1    Wirbelauer, C.2    Jaroszewski, J.3    Hartmann, C.4    Pham, D.T.5
  • 14
    • 0023952057 scopus 로고
    • Side effects in excimer corneal surgery. Corneal thermal gradients
    • doi: 10.1007/BF02181196
    • Bende T, Seiler T, Wollensak J (1988) Side effects in excimer corneal surgery. Corneal thermal gradients. Graefes Arch Clin Exp Ophthalmol 226:277-280. doi: 10.1007/BF02181196
    • (1988) Graefes Arch Clin Exp Ophthalmol , vol.226 , pp. 277-280
    • Bende, T.1    Seiler, T.2    Wollensak, J.3
  • 15
    • 0021059068 scopus 로고
    • Phase transitions in ocular tissue: NMR and temperature measurements
    • doi: 10.1007/BF02133850
    • Seiler T, Muller-Stolzenburg N, Wollensak J (1983) Phase transitions in ocular tissue: NMR and temperature measurements. Graefes Arch Clin Exp Ophthalmol 221:122-125. doi: 10.1007/BF02133850
    • (1983) Graefes Arch Clin Exp Ophthalmol , vol.221 , pp. 122-125
    • Seiler, T.1    Muller-Stolzenburg, N.2    Wollensak, J.3
  • 16
    • 9144242769 scopus 로고    scopus 로고
    • Clinical photoablation with a 500-Hz scanning spot excimer laser
    • Iseli HP, Mrochen M, Hafezi F, Seller T (2004) Clinical photoablation with a 500-Hz scanning spot excimer laser. J Refract Surg 20:831-834
    • (2004) J Refract Surg , vol.20 , pp. 831-834
    • Iseli, H.P.1    Mrochen, M.2    Hafezi, F.3    Seller, T.4