메뉴 건너뛰기




Volumn 25, Issue 2, 2006, Pages 182-184

Continuous measurement of corneal dehydration with online optical coherence pachymetry

Author keywords

Corneal dehydration; Corneal thickness measurement; Online optical coherence pachymetry

Indexed keywords

ADULT; ARTICLE; CLINICAL ARTICLE; CORNEA DEHYDRATION; CORNEA THICKNESS; DEHYDRATION; HUMAN; KERATOMILEUSIS; ONLINE MONITORING; ONLINE OPTICAL COHERENCE PACHYMETRY; PATIENT MONITORING; PEROPERATIVE COMPLICATION; PHOTOREFRACTIVE KERATECTOMY; PRIORITY JOURNAL;

EID: 33644836123     PISSN: 02773740     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.ico.0000176610.50461.77     Document Type: Article
Times cited : (27)

References (25)
  • 1
    • 0021798816 scopus 로고
    • In vivo assessment of mechanisms controlling corneal hydration
    • O'Neal M, Polse K. In vivo assessment of mechanisms controlling corneal hydration. Invest Ophthalmol Vis Sci. 1985;26:849-856.
    • (1985) Invest Ophthalmol Vis Sci , vol.26 , pp. 849-856
    • O'Neal, M.1    Polse, K.2
  • 2
    • 0025762705 scopus 로고
    • Effect of humidity on the deswelling function of the human cornea
    • Bourassa S, Benjamin W, Boltz R. Effect of humidity on the deswelling function of the human cornea. Curr Eye Res. 1991;10:493-500.
    • (1991) Curr Eye Res , vol.10 , pp. 493-500
    • Bourassa, S.1    Benjamin, W.2    Boltz, R.3
  • 3
    • 11144314293 scopus 로고    scopus 로고
    • Continuous monitoring of corneal thickness changes during LASIK with online optical coherence pachymetry
    • Wirbelauer C, Pham DT. Continuous monitoring of corneal thickness changes during LASIK with online optical coherence pachymetry. J Cataract Refract Surg. 2004;30:2559-2568.
    • (2004) J Cataract Refract Surg , vol.30 , pp. 2559-2568
    • Wirbelauer, C.1    Pham, D.T.2
  • 5
    • 1142263157 scopus 로고    scopus 로고
    • Experimental evaluation of online optical coherence pachymetry for corneal refractive surgery
    • Wirbelauer C, Aurich H, Jaroszewski J, et al. Experimental evaluation of online optical coherence pachymetry for corneal refractive surgery. Graefes Arch Clin Exp Ophthalmol. 2004;242:24-30.
    • (2004) Graefes Arch Clin Exp Ophthalmol , vol.242 , pp. 24-30
    • Wirbelauer, C.1    Aurich, H.2    Jaroszewski, J.3
  • 6
    • 10744231521 scopus 로고    scopus 로고
    • Optische Online-Pachymetrie bei Laser-in-situ-Keratomileusis
    • Wirbelauer C, Häberle U, Pham DT. Optische Online-Pachymetrie bei Laser-in-situ-Keratomileusis. Ophthalmologe. 2004;101:140-145.
    • (2004) Ophthalmologe , vol.101 , pp. 140-145
    • Wirbelauer, C.1    Häberle, U.2    Pham, D.T.3
  • 7
    • 0035036808 scopus 로고    scopus 로고
    • Corneal hydration affects ablation during laser in situ keratomileusis surgery
    • Kim W, Jo J. Corneal hydration affects ablation during laser in situ keratomileusis surgery. Cornea. 2001;20:394-397.
    • (2001) Cornea , vol.20 , pp. 394-397
    • Kim, W.1    Jo, J.2
  • 8
    • 0032805632 scopus 로고    scopus 로고
    • Corneal perforation during laser in situ keratomileusis
    • Joo C, Kim T. Corneal perforation during laser in situ keratomileusis. J Cataract Refract Surg. 1999;25:1165-1167.
    • (1999) J Cataract Refract Surg , vol.25 , pp. 1165-1167
    • Joo, C.1    Kim, T.2
  • 9
    • 0027954062 scopus 로고
    • Excimer laser ablation rate and corneal hydration
    • Dougherty P, Wellish K, Maloney R. Excimer laser ablation rate and corneal hydration. Am J Ophthalmol. 1994;118:169-176.
    • (1994) Am J Ophthalmol , vol.118 , pp. 169-176
    • Dougherty, P.1    Wellish, K.2    Maloney, R.3
  • 10
    • 0019940347 scopus 로고
    • Light scattering from the human cornea
    • Olsen T. Light scattering from the human cornea. Invest Ophthalmol Vis Sci. 1982;23:81-86.
    • (1982) Invest Ophthalmol Vis Sci , vol.23 , pp. 81-86
    • Olsen, T.1
  • 11
    • 0031678530 scopus 로고    scopus 로고
    • Corneal hydration monitored by laser-induced breakdown spectroscopy
    • Pallikaris I, Ginis H, Kounis G, et al. Corneal hydration monitored by laser-induced breakdown spectroscopy. J Refract Surg. 1998;14:655-660.
    • (1998) J Refract Surg , vol.14 , pp. 655-660
    • Pallikaris, I.1    Ginis, H.2    Kounis, G.3
  • 12
    • 0034536577 scopus 로고    scopus 로고
    • Corneal optical coherence tomography before and immediately after excimer laser photorefractive keratectomy
    • Wirbelauer C, Scholz C, Hoerauf H, et al. Corneal optical coherence tomography before and immediately after excimer laser photorefractive keratectomy. Am J Ophthalmol. 2000;130:693-699.
    • (2000) Am J Ophthalmol , vol.130 , pp. 693-699
    • Wirbelauer, C.1    Scholz, C.2    Hoerauf, H.3
  • 13
    • 0025992365 scopus 로고
    • The use of the 193-nm excimer laser for myopic photorefractive keratectomy in sighted eyes. A multicenter study
    • Sher N, Chen V, Bowers R, et al. The use of the 193-nm excimer laser for myopic photorefractive keratectomy in sighted eyes. A multicenter study. Arch Ophthalmol. 1991;109:1525-1530.
    • (1991) Arch Ophthalmol , vol.109 , pp. 1525-1530
    • Sher, N.1    Chen, V.2    Bowers, R.3
  • 14
    • 0005619433 scopus 로고
    • Corneal thickness changes during ultrasound pachymetry for radial keratotomy
    • Bolton C, Herman W. Corneal thickness changes during ultrasound pachymetry for radial keratotomy. J Refract Surg. 1986;2:221-222.
    • (1986) J Refract Surg , vol.2 , pp. 221-222
    • Bolton, C.1    Herman, W.2
  • 15
    • 0019431990 scopus 로고
    • Changes in corneal thickness during radial keratotomy
    • Villasenor R, Salz J, Steel D, et al. Changes in corneal thickness during radial keratotomy. Ophthalmic Surg. 1981;12:341-342.
    • (1981) Ophthalmic Surg , vol.12 , pp. 341-342
    • Villasenor, R.1    Salz, J.2    Steel, D.3
  • 16
    • 0028209182 scopus 로고
    • Hydration changes in cadaver eyes prepared for practice and experimental surgery
    • Terry M, Ousley P, Zjhra M. Hydration changes in cadaver eyes prepared for practice and experimental surgery. Arch Ophthalmol. 1994;112:538-543.
    • (1994) Arch Ophthalmol , vol.112 , pp. 538-543
    • Terry, M.1    Ousley, P.2    Zjhra, M.3
  • 17
    • 0842326971 scopus 로고    scopus 로고
    • Continuous non-contact corneal pachymetry with a high speed reflectometer
    • Böhnke M, Chavanne P, Gianotti R, et al. Continuous non-contact corneal pachymetry with a high speed reflectometer. J Refract Surg. 1998; 14:140-146.
    • (1998) J Refract Surg , vol.14 , pp. 140-146
    • Böhnke, M.1    Chavanne, P.2    Gianotti, R.3
  • 18
    • 0002762554 scopus 로고    scopus 로고
    • Structure and function of the cornea
    • Kaufman HH, et al, eds: Boston: Butterworth-Heinemann
    • Klyce S, Beuerman R. Structure and function of the cornea. In Kaufman HH, et al, eds: The Cornea. 2nd ed. Boston: Butterworth-Heinemann 1997, pp 3-50.
    • (1997) The Cornea. 2nd Ed. , pp. 3-50
    • Klyce, S.1    Beuerman, R.2
  • 19
    • 0030274621 scopus 로고    scopus 로고
    • High-precision, high-speed measurement of excimer laser keratectomies with a new optical pachymeter
    • Böhnke M, Chavanne P, Gianotti R, et al. High-precision, high-speed measurement of excimer laser keratectomies with a new optical pachymeter. Ger J Ophthalmol. 1997;5:338-342.
    • (1997) Ger J Ophthalmol , vol.5 , pp. 338-342
    • Böhnke, M.1    Chavanne, P.2    Gianotti, R.3
  • 20
    • 0035470990 scopus 로고    scopus 로고
    • Real-time pachymetry during photorefractive keratectomy using optical low-coherence reflectometry
    • Böhnke M, Widmer S, Walti R. Real-time pachymetry during photorefractive keratectomy using optical low-coherence reflectometry. J Biomed Opt. 2001;6:412-417.
    • (2001) J Biomed Opt , vol.6 , pp. 412-417
    • Böhnke, M.1    Widmer, S.2    Walti, R.3
  • 21
    • 0036181034 scopus 로고    scopus 로고
    • The measurement of corneal epithelial thickness in response to hypoxia using optical coherence tomography
    • Wang J, Fonn D, Simpson T, et al. The measurement of corneal epithelial thickness in response to hypoxia using optical coherence tomography. Am J Ophthalmol. 2002;133:315-319.
    • (2002) Am J Ophthalmol , vol.133 , pp. 315-319
    • Wang, J.1    Fonn, D.2    Simpson, T.3
  • 22
    • 0013850022 scopus 로고
    • Thinning in the human cornea on awakening
    • Mandell R, Fatt I. Thinning in the human cornea on awakening. Nature. 1965;208:292.
    • (1965) Nature , vol.208 , pp. 292
    • Mandell, R.1    Fatt, I.2
  • 23
    • 0022801644 scopus 로고
    • Ablation of polymers and biological tissue by ultraviolet lasers
    • Srinivisan R. Ablation of polymers and biological tissue by ultraviolet lasers. Science. 1986;234:559-565.
    • (1986) Science , vol.234 , pp. 559-565
    • Srinivisan, R.1
  • 24
    • 0023280455 scopus 로고
    • High-speed photography of excimer laser ablation of the cornea
    • Puliafito C, Stern D, Krueger R, et al. High-speed photography of excimer laser ablation of the cornea. Arch Ophthalmol. 1987;105:1255-1259.
    • (1987) Arch Ophthalmol , vol.105 , pp. 1255-1259
    • Puliafito, C.1    Stern, D.2    Krueger, R.3
  • 25
    • 0023952057 scopus 로고
    • Side effects in excimer corneal surgery. Corneal thermal gradients
    • Bende T, Seiler T, Wollensak J. Side effects in excimer corneal surgery. Corneal thermal gradients. Graefes Arch Clin Exp Ophthalmol. 1988;226: 277-280.
    • (1988) Graefes Arch Clin Exp Ophthalmol , vol.226 , pp. 277-280
    • Bende, T.1    Seiler, T.2    Wollensak, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.