메뉴 건너뛰기




Volumn 18, Issue 10, 2009, Pages 1478-1485

Non-fusion instrumentation of the lumbar spine with a hinged pedicle screw rod system: An in vitro experiment

Author keywords

Biomechanics; Decompression; Dynamic stabilisation; Lumbar spine

Indexed keywords

ARTICLE; BIOMECHANICS; CONTROLLED STUDY; DECOMPRESSION SURGERY; HUMAN; HUMAN TISSUE; IN VITRO STUDY; INTRAMEDULLARY NAILING; LUMBAR SPINE; PEDICLE SCREW; PRIORITY JOURNAL; RANGE OF MOTION; SPINE INSTABILITY; SPINE STABILIZATION;

EID: 70349687456     PISSN: 09406719     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00586-009-1052-3     Document Type: Article
Times cited : (44)

References (34)
  • 1
    • 0019722388 scopus 로고
    • The relevance of torsion to the mechanical derangement of the lumbar spine
    • DOI 10.1097/00007632-198105000-00006
    • MA Adams WC Hutton 1981 The relevance of torsion to the mechanical derangement of the lumbar spine Spine 6 241 248 10.1097/00007632-198105000-00006 7268544 10.1097/00007632-198105000-00006 1:STN:280:DyaL3M3nsFSkug%3D%3D (Pubitemid 12086697)
    • (1981) Spine , vol.6 , Issue.3 , pp. 241-248
    • Adams, M.A.1    Hutton, W.C.2
  • 2
    • 41049108276 scopus 로고    scopus 로고
    • Dynesys fixation for lumbar spine degeneration
    • 10.1007/s10143-007-0101-9 17906883 10.1007/s10143-007-0101-9
    • M Bothmann E Kast GJ Boldt J Oberle 2008 Dynesys fixation for lumbar spine degeneration Neurosurg Rev 31 189 196 10.1007/s10143-007-0101-9 17906883 10.1007/s10143-007-0101-9
    • (2008) Neurosurg Rev , vol.31 , pp. 189-196
    • Bothmann, M.1    Kast, E.2    Boldt, G.J.3    Oberle, J.4
  • 3
    • 35848953389 scopus 로고    scopus 로고
    • Immediate biomechanical effects of lumbar posterior dynamic stabilization above a circumferential fusion
    • DOI 10.1097/BRS.0b013e318158cdbe, PII 0000763220071101000007
    • BC Cheng J Gordon J Cheng WC Welch 2007 Immediate biomechanical effects of lumbar posterior dynamic stabilization above a circumferential fusion Spine 32 2551 2557 10.1097/BRS.0b013e318158cdbe 17978653 10.1097/BRS.0b013e318158cdbe (Pubitemid 350059481)
    • (2007) Spine , vol.32 , Issue.23 , pp. 2551-2557
    • Cheng, B.C.1    Gordon, J.2    Cheng, J.3    Welch, W.C.4
  • 4
    • 0034650806 scopus 로고    scopus 로고
    • Load-sharing characteristics of stabilized lumbar spine segments
    • DOI 10.1097/00007632-200001150-00006
    • PA Cripton GM Jain RH Wittenberg LP Nolte 2000 Load-sharing characteristics of stabilized lumbar spine segments Spine 25 170 179 10.1097/00007632-200001150-00006 10685480 10.1097/00007632-200001150-00006 1:STN:280:DC%2BD3c7kvFOnsw%3D%3D (Pubitemid 30084269)
    • (2000) Spine , vol.25 , Issue.2 , pp. 170-179
    • Cripton, P.A.1    Jain, G.M.2    Wittenberg, R.H.3    Nolte, L.-P.4
  • 5
    • 43149096927 scopus 로고    scopus 로고
    • En bloc spondylectomy reconstructions in a biomechanical in-vitro study
    • 10.1007/s00586-008-0588-y 18196295 10.1007/s00586-008-0588-y 1:STN:280:DC%2BD1c3psVyhsA%3D%3D
    • AC Disch KD Schaser I Melcher A Luzzati F Feraboli W Schmoelz 2008 En bloc spondylectomy reconstructions in a biomechanical in-vitro study Eur Spine J 17 715 725 10.1007/s00586-008-0588-y 18196295 10.1007/s00586-008-0588-y 1:STN:280:DC%2BD1c3psVyhsA%3D%3D
    • (2008) Eur Spine J , vol.17 , pp. 715-725
    • Disch, A.C.1    Schaser, K.D.2    Melcher, I.3    Luzzati, A.4    Feraboli, F.5    Schmoelz, W.6
  • 6
    • 41949133913 scopus 로고    scopus 로고
    • Higher risk of adjacent segment degeneration after floating fusions: Long-term outcome after low lumbar spine fusions
    • 10.1097/BSD.0b013e3180577259 18391709 10.1097/BSD.0b013e3180577259
    • AC Disch W Schmoelz G Matziolis SV Schneider C Knop M Putzier 2008 Higher risk of adjacent segment degeneration after floating fusions: long-term outcome after low lumbar spine fusions J Spinal Disord Tech 21 79 85 10.1097/BSD.0b013e3180577259 18391709 10.1097/BSD.0b013e3180577259
    • (2008) J Spinal Disord Tech , vol.21 , pp. 79-85
    • Disch, A.C.1    Schmoelz, W.2    Matziolis, G.3    Schneider, S.V.4    Knop, C.5    Putzier, M.6
  • 7
    • 20344391718 scopus 로고    scopus 로고
    • The use of an interspinous implant in conjunction with a graded facetectomy procedure
    • DOI 10.1097/01.brs.0000164152.32734.d2
    • PD Fuchs DP Lindsey KY Hsu JF Zucherman SA Yerby 2005 The use of an interspinous implant in conjunction with a graded facetectomy procedure Spine 30 1266 1272 10.1097/01.brs.0000164152.32734.d2 15928550 10.1097/01.brs. 0000164152.32734.d2 discussion 1273-1274 (Pubitemid 40791322)
    • (2005) Spine , vol.30 , Issue.11 , pp. 1266-1272
    • Fuchs, P.D.1    Lindsey, D.P.2    Hsu, K.Y.3    Zucherman, J.F.4    Yerby, S.A.5
  • 8
    • 0034416839 scopus 로고    scopus 로고
    • The effect of disc degeneration and facet joint osteoarthritis on the segmental flexibility of the lumbar spine
    • 10.1097/00007632-200012010-00011 11145815 10.1097/00007632-200012010- 00011 1:STN:280:DC%2BD3M7gsFKlsA%3D%3D
    • A Fujiwara TH Lim HS An N Tanaka CH Jeon GB Andersson VM Haughton 2000 The effect of disc degeneration and facet joint osteoarthritis on the segmental flexibility of the lumbar spine Spine 25 3036 3044 10.1097/00007632-200012010- 00011 11145815 10.1097/00007632-200012010-00011 1:STN:280:DC%2BD3M7gsFKlsA%3D%3D
    • (2000) Spine , vol.25 , pp. 3036-3044
    • Fujiwara, A.1    Lim, T.H.2    An, H.S.3    Tanaka, N.4    Jeon, C.H.5    Andersson, G.B.6    Haughton, V.M.7
  • 10
    • 33645559233 scopus 로고    scopus 로고
    • Test protocols for evaluation of spinal implants
    • 10.2106/JBJS.E.01363 16595454 10.2106/JBJS.E.01363
    • VK Goel MM Panjabi AG Patwardhan AP Dooris H Serhan 2006 Test protocols for evaluation of spinal implants J Bone Joint Surg Am 88 Suppl 2 103 109 10.2106/JBJS.E.01363 16595454 10.2106/JBJS.E.01363
    • (2006) J Bone Joint Surg Am , vol.88 , Issue.SUPPL 2 , pp. 103-109
    • Goel, V.K.1    Panjabi, M.M.2    Patwardhan, A.G.3    Dooris, A.P.4    Serhan, H.5
  • 11
    • 13444300930 scopus 로고    scopus 로고
    • Clinical experience with the dynesys semirigid fixation system for the lumbar spine: Surgical and patient-oriented outcome in 50 cases after an average of 2 years
    • DOI 10.1097/01.brs.0000152584.46266.25
    • D Grob A Benini A Junge AF Mannion 2005 Clinical experience with the Dynesys semirigid fixation system for the lumbar spine: surgical and patient-oriented outcome in 50 cases after an average of 2 years Spine 30 324 331 10.1097/01.brs.0000152584.46266.25 15682014 10.1097/01.brs.0000152584.46266. 25 (Pubitemid 40209259)
    • (2005) Spine , vol.30 , Issue.3 , pp. 324-331
    • Grob, D.1    Benini, A.2    Junge, A.3    Mannion, A.F.4
  • 12
    • 8644271684 scopus 로고    scopus 로고
    • Adjacent segment degeneration and adjacent segment disease: The consequences of spinal fusion?
    • DOI 10.1016/j.spinee.2004.07.007, PII S152994300400573X
    • AS Hilibrand M Robbins 2004 Adjacent segment degeneration and adjacent segment disease: the consequences of spinal fusion? Spine J 4 190S 194S 10.1016/j.spinee.2004.07.007 15541666 10.1016/j.spinee.2004.07.007 (Pubitemid 39497304)
    • (2004) Spine Journal , vol.4
    • Hilibrand, A.S.1    Robbins, M.2
  • 13
    • 38649128507 scopus 로고    scopus 로고
    • Can a modified interspinous spacer prevent instability in axial rotation and lateral bending? A biomechanical in vitro study resulting in a new idea
    • DOI 10.1016/j.clinbiomech.2007.09.004, PII S026800330700191X
    • A Kettler J Drumm F Heuer K Haeussler C Mack L Claes HJ Wilke 2008 Can a modified interspinous spacer prevent instability in axial rotation and lateral bending? A biomechanical in vitro study resulting in a new idea Clin Biomech (Bristol, Avon) 23 242 247 10.1016/j.clinbiomech.2007.09.004 10.1016/j.clinbiomech.2007.09.004 1:STN:280:DC%2BD1c%2FotlCmsg%3D%3D (Pubitemid 351172529)
    • (2008) Clinical Biomechanics , vol.23 , Issue.2 , pp. 242-247
    • Kettler, A.1    Drumm, J.2    Heuer, F.3    Haeussler, K.4    Mack, C.5    Claes, L.6    Wilke, H.-J.7
  • 14
    • 34547444113 scopus 로고    scopus 로고
    • Classification of posterior dynamic stabilization devices
    • 10.3171/foc.2007.22.1.3 17608337 10.3171/foc.2007.22.1.3
    • P Khoueir KA Kim MY Wang 2007 Classification of posterior dynamic stabilization devices Neurosurg Focus 22 E3 10.3171/foc.2007.22.1.3 17608337 10.3171/foc.2007.22.1.3
    • (2007) Neurosurg Focus , vol.22 , pp. 3
    • Khoueir, P.1    Kim, K.A.2    Wang, M.Y.3
  • 15
    • 4143108931 scopus 로고    scopus 로고
    • A biomechanical comparison of supplementary posterior translaminar facet and transfacetopedicular screw fixation after anterior lumbar interbody fusion
    • 15291029 10.3171/spi.2004.1.1.0101
    • SM Kim TJ Lim J Paterno DH Kim 2004 A biomechanical comparison of supplementary posterior translaminar facet and transfacetopedicular screw fixation after anterior lumbar interbody fusion J Neurosurg Spine 1 101 107 15291029 10.3171/spi.2004.1.1.0101
    • (2004) J Neurosurg Spine , vol.1 , pp. 101-107
    • Kim, S.M.1    Lim, T.J.2    Paterno, J.3    Kim, D.H.4
  • 16
    • 0034533688 scopus 로고    scopus 로고
    • Three-dimensional motion analysis with Synex: Comparative biomechanical test series with a new vertebral body replacement for the thoracolumbar spine
    • DOI 10.1007/s005860000185
    • C Knop U Lange L Bastian M Blauth 2000 Three-dimensional motion analysis with Synex. Comparative biomechanical test series with a new vertebral body replacement for the thoracolumbar spine Eur Spine J 9 472 485 10.1007/s005860000185 11189915 10.1007/s005860000185 1:STN:280: DC%2BD3M7ltlajsQ%3D%3D (Pubitemid 32005650)
    • (2000) European Spine Journal , vol.9 , Issue.6 , pp. 472-485
    • Knop, C.1    Lange, U.2    Bastian, L.3    Blauth, M.4
  • 17
    • 54849413667 scopus 로고    scopus 로고
    • Use of instrumented pedicle screws to evaluate load sharing in posterior dynamic stabilization systems
    • 10.1016/j.spinee.2007.08.008 18037350 10.1016/j.spinee.2007.08.008
    • K Meyers M Tauber Y Sudin S Fleischer U Arnin F Girardi T Wright 2008 Use of instrumented pedicle screws to evaluate load sharing in posterior dynamic stabilization systems Spine J 8 926 932 10.1016/j.spinee.2007.08.008 18037350 10.1016/j.spinee.2007.08.008
    • (2008) Spine J , vol.8 , pp. 926-932
    • Meyers, K.1    Tauber, M.2    Sudin, Y.3    Fleischer, S.4    Arnin, U.5    Girardi, F.6    Wright, T.7
  • 18
    • 33745016686 scopus 로고    scopus 로고
    • Biomechanical characterization of the three-dimensional kinematic behaviour of the Dynesys dynamic stabilization system: An in vitro study
    • DOI 10.1007/s00586-005-0948-9
    • CA Niosi QA Zhu DC Wilson O Keynan DR Wilson TR Oxland 2006 Biomechanical characterization of the three-dimensional kinematic behaviour of the Dynesys dynamic stabilization system: an in vitro study Eur Spine J 15 913 922 10.1007/s00586-005-0948-9 16217663 10.1007/s00586-005-0948-9 (Pubitemid 43873780)
    • (2006) European Spine Journal , vol.15 , Issue.6 , pp. 913-922
    • Niosi, C.A.1    Zhu, Q.A.2    Wilson, D.C.3    Keynan, O.4    Wilson, D.R.5    Oxland, T.R.6
  • 19
    • 0023723917 scopus 로고
    • Biomechanical evaluation of spinal fixation devices: I. A conceptual framework
    • 3206270 1:STN:280:DyaL1M%2FosVKmuw%3D%3D
    • MM Panjabi 1988 Biomechanical evaluation of spinal fixation devices: I. A conceptual framework Spine 13 1129 1134 3206270 1:STN:280: DyaL1M%2FosVKmuw%3D%3D
    • (1988) Spine , vol.13 , pp. 1129-1134
    • Panjabi, M.M.1
  • 20
    • 37249006809 scopus 로고    scopus 로고
    • StabilimaxNZ® versus simulated fusion: Evaluation of adjacent-level effects
    • DOI 10.1007/s00586-007-0444-5
    • ® versus simulated fusion: evaluation of adjacent-level effects Eur Spine J 16 2159 2165 10.1007/s00586-007-0444-5 17924151 10.1007/s00586-007-0444-5 (Pubitemid 350276080)
    • (2007) European Spine Journal , vol.16 , Issue.12 , pp. 2159-2165
    • Panjabi, M.M.1    Henderson, G.2    James, Y.3    Timm, J.P.4
  • 21
    • 0022354031 scopus 로고
    • Biomechanical time-tolerance of fresh cadaveric human spine specimens
    • DOI 10.1002/jor.1100030305
    • MM Panjabi M Krag D Summers T Videman 1985 Biomechanical time-tolerance of fresh cadaveric human spine specimens J Orthop Res 3 292 300 10.1002/jor.1100030305 4032102 10.1002/jor.1100030305 1:STN:280: DyaL2M3pt1aqsQ%3D%3D (Pubitemid 16247029)
    • (1985) Journal of Orthopaedic Research , vol.3 , Issue.3 , pp. 292-300
    • Panjabi, M.M.1    Krag, M.2    Summers, D.3    Videman, T.4
  • 22
    • 0028350725 scopus 로고
    • Mechanical behavior of the human lumbar and lumbosacral spine as shown by three-dimensional load-displacement curves
    • 8126047 1:STN:280:DyaK2c7ntFylsw%3D%3D
    • MM Panjabi TR Oxland I Yamamoto JJ Crisco 1994 Mechanical behavior of the human lumbar and lumbosacral spine as shown by three-dimensional load-displacement curves J Bone Joint Surg Am 76 413 424 8126047 1:STN:280:DyaK2c7ntFylsw%3D%3D
    • (1994) J Bone Joint Surg Am , vol.76 , pp. 413-424
    • Panjabi, M.M.1    Oxland, T.R.2    Yamamoto, I.3    Crisco, J.J.4
  • 23
    • 33750528449 scopus 로고    scopus 로고
    • Biomechanics of posterior dynamic stabilizing device (DIAM) after facetectomy and discectomy
    • DOI 10.1016/j.spinee.2006.02.003, PII S1529943006000544
    • FM Phillips LI Voronov IN Gaitanis G Carandang RM Havey AG Patwardhan 2006 Biomechanics of posterior dynamic stabilizing device (DIAM) after facetectomy and discectomy Spine J 6 714 722 10.1016/j.spinee.2006.02.003 17088203 10.1016/j.spinee.2006.02.003 (Pubitemid 44660872)
    • (2006) Spine Journal , vol.6 , Issue.6 , pp. 714-722
    • Phillips, F.M.1    Voronov, L.I.2    Gaitanis, I.N.3    Carandang, G.4    Havey, R.M.5    Patwardhan, A.G.6
  • 24
    • 0031864134 scopus 로고    scopus 로고
    • Laminectomy and functional impairment of the lumbar spine: The importance of muscle forces in flexible and rigid instrumented stabilization - A biomechanical study in vitro
    • DOI 10.1007/s005860050062
    • U Quint HJ Wilke F Loer L Claes 1998 Laminectomy and functional impairment of the lumbar spine: the importance of muscle forces in flexible and rigid instrumented stabilization-a biomechanical study in vitro Eur Spine J 7 229 238 10.1007/s005860050062 9684957 10.1007/s005860050062 1:STN:280: DyaK1czkvVSquw%3D%3D (Pubitemid 28313835)
    • (1998) European Spine Journal , vol.7 , Issue.3 , pp. 229-238
    • Quint, U.1    Wilke, H.-J.2    Loer, F.3    Claes, L.4
  • 25
    • 0042069550 scopus 로고    scopus 로고
    • Dynamic stabilization of the lumbar spine and its effects on adjacent segments: An in vitro experiment
    • 12902959 1:STN:280:DC%2BD3szmvVCgsw%3D%3D
    • W Schmoelz JF Huber T Nydegger L Claes HJ Wilke 2003 Dynamic stabilization of the lumbar spine and its effects on adjacent segments: an in vitro experiment J Spinal Disord Tech 16 418 423 12902959 1:STN:280: DC%2BD3szmvVCgsw%3D%3D
    • (2003) J Spinal Disord Tech , vol.16 , pp. 418-423
    • Schmoelz, W.1    Huber, J.F.2    Nydegger, T.3    Claes, L.4    Wilke, H.J.5
  • 26
    • 49249088983 scopus 로고    scopus 로고
    • The effect of dynamic, semi-rigid implants on the range of motion of lumbar motion segments after decompression
    • 10.1007/s00586-008-0667-0 18493802 10.1007/s00586-008-0667-0
    • TL Schulte C Hurschler M Haversath U Liljenqvist V Bullmann TJ Filler N Osada EM Fallenberg L Hackenberg 2008 The effect of dynamic, semi-rigid implants on the range of motion of lumbar motion segments after decompression Eur Spine J 17 1057 1065 10.1007/s00586-008-0667-0 18493802 10.1007/s00586-008-0667-0
    • (2008) Eur Spine J , vol.17 , pp. 1057-1065
    • Schulte, T.L.1    Hurschler, C.2    Haversath, M.3    Liljenqvist, U.4    Bullmann, V.5    Filler, T.J.6    Osada, N.7    Fallenberg, E.M.8    Hackenberg, L.9
  • 27
    • 0032745331 scopus 로고    scopus 로고
    • Stability analysis of an enhanced load sharing posterior fixation device and its equivalent conventional device in a calf spine model
    • DOI 10.1097/00007632-199911010-00006
    • JL Scifert K Sairyo VK Goel LJ Grobler NM Grosland KF Spratt KD Chesmel 1999 Stability analysis of an enhanced load sharing posterior fixation device and its equivalent conventional device in a calf spine model Spine 24 2206 2213 10.1097/00007632-199911010-00006 10562985 10.1097/00007632-199911010-00006 1:STN:280:DC%2BD3c%2FivVOhtw%3D%3D (Pubitemid 29518023)
    • (1999) Spine , vol.24 , Issue.21 , pp. 2206-2213
    • Scifert, J.L.1    Sairyo, K.2    Goel, V.K.3    Grobler, L.J.4    Grosland, N.M.5    Spratt, K.F.6    Chesmel, K.D.7
  • 28
    • 0036035142 scopus 로고    scopus 로고
    • The dynamic neutralization system for the spine: A multi-center study of a novel non-fusion system
    • 12384741
    • TM Stoll G Dubois O Schwarzenbach 2002 The dynamic neutralization system for the spine: a multi-center study of a novel non-fusion system Eur Spine J 11 Suppl 2 S170 S178 12384741
    • (2002) Eur Spine J , vol.11 , Issue.SUPPL 2
    • Stoll, T.M.1    Dubois, G.2    Schwarzenbach, O.3
  • 29
    • 49249109406 scopus 로고    scopus 로고
    • Biomechanical effect of different lumbar interspinous implants on flexibility and intradiscal pressure
    • 18584219 10.1007/s00586-008-0657-2
    • HJ Wilke J Drumm K Haussler C Mack WI Steudel A Kettler 2008 Biomechanical effect of different lumbar interspinous implants on flexibility and intradiscal pressure Eur Spine J 17 1049 1056 18584219 10.1007/s00586-008- 0657-2
    • (2008) Eur Spine J , vol.17 , pp. 1049-1056
    • Wilke, H.J.1    Drumm, J.2    Haussler, K.3    MacK, C.4    Steudel, W.I.5    Kettler, A.6
  • 30
    • 70349724512 scopus 로고    scopus 로고
    • Design optimization of a new posterior dynamic stabilization system
    • 10.1016/S0021-9290(08)70312-9 10.1016/S0021-9290(08)70312-9
    • HJ Wilke F Heuer H Schmidt 2008 Design optimization of a new posterior dynamic stabilization system J Biomech 41 Suppl 1 S313 10.1016/S0021-9290(08) 70312-9 10.1016/S0021-9290(08)70312-9
    • (2008) J Biomech , vol.41 , Issue.SUPPL 1 , pp. 313
    • Wilke, H.J.1    Heuer, F.2    Schmidt, H.3
  • 31
    • 0031925505 scopus 로고    scopus 로고
    • Spinal segment range of motion as a function of in vitro test conditions: Effects of exposure period, accumulated cycles, angular- deformation rate, and moisture condition
    • DOI 10.1002/(SICI)1097-0185(199805)251:1<15::AID-AR4>3.0.CO;2-D
    • HJ Wilke B Jungkunz K Wenger LE Claes 1998 Spinal segment range of motion as a function of in vitro test conditions: effects of exposure period, accumulated cycles, angular-deformation rate, and moisture condition Anat Rec 251 15 19 10.1002/(SICI)1097-0185(199805)251:1<15::AID-AR4>3.0.CO;2-D 9605215 10.1002/(SICI)1097-0185(199805)251:1<15::AID-AR4>3.0.CO;2-D 1:STN:280:DyaK1c3ms1amsw%3D%3D (Pubitemid 28193945)
    • (1998) Anatomical Record , vol.251 , Issue.1 , pp. 15-19
    • Wilke, H.-J.1    Jungkunz, B.2    Wenger, K.3    Claes, L.E.4
  • 32
    • 33751116552 scopus 로고    scopus 로고
    • Biomechanical evaluation of a new total posterior-element replacement system
    • DOI 10.1097/01.brs.0000245872.45554.c0, PII 0000763220061115000007
    • HJ Wilke H Schmidt K Werner W Schmolz J Drumm 2006 Biomechanical evaluation of a new total posterior-element replacement system Spine 31 2790 2796 10.1097/01.brs.0000245872.45554.c0 17108830 10.1097/01.brs.0000245872. 45554.c0 discussion 2797 (Pubitemid 44772778)
    • (2006) Spine , vol.31 , Issue.24 , pp. 2790-2796
    • Wilke, H.-J.1    Schmidt, H.2    Werner, K.3    Schmolz, W.4    Drumm, J.5
  • 33
    • 0031924426 scopus 로고    scopus 로고
    • Testing criteria for spinal implants: Recommendations for the standardization of in vitro stability testing of spinal implants
    • DOI 10.1007/s005860050045
    • HJ Wilke K Wenger L Claes 1998 Testing criteria for spinal implants: recommendations for the standardization of in vitro stability testing of spinal implants Eur Spine J 7 148 154 10.1007/s005860050045 9629939 10.1007/s005860050045 1:STN:280:DyaK1c3ptFyqsw%3D%3D (Pubitemid 28223601)
    • (1998) European Spine Journal , vol.7 , Issue.2 , pp. 148-154
    • Wilke, H.-J.1    Wenger, K.2    Claes, L.3
  • 34
    • 0042737755 scopus 로고    scopus 로고
    • Influence of graded facetectomy and laminectomy on spinal biomechanics
    • DOI 10.1007/s00586-003-0540-0
    • T Zander A Rohlmann C Klockner G Bergmann 2003 Influence of graded facetectomy and laminectomy on spinal biomechanics Eur Spine J 12 427 434 10.1007/s00586-003-0540-0 12720068 10.1007/s00586-003-0540-0 1:STN:280:DC%2BD3svhsFensA%3D%3D (Pubitemid 37108415)
    • (2003) European Spine Journal , vol.12 , Issue.4 , pp. 427-434
    • Zander, T.1    Rohlmann, A.2    Klockner, C.3    Bergmann, G.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.