메뉴 건너뛰기




Volumn 36, Issue 10, 2009, Pages 4634-4643

Development of a high precision dosimetry system for the measurement of surface dose rate distribution for eye applicators

Author keywords

Brachytherapy; Eye applicator; Ophthalmic plaque dosimetry; Plastic scintillator dosimetry

Indexed keywords

BUDGET CONTROL; DOSIMETRY; ONCOLOGY; QUALITY ASSURANCE; RADIOTHERAPY; SCINTILLATION COUNTERS; UNCERTAINTY ANALYSIS;

EID: 70349668981     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3218762     Document Type: Article
Times cited : (22)

References (17)
  • 1
    • 0016273795 scopus 로고
    • Treatment of chorodial melanomas with Ru-106/Rh-106 beta ray applicators
    • 0039-6257.
    • P. K. Lommatzsch, " Treatment of chorodial melanomas with Ru-106/Rh-106 beta ray applicators.," Surv. Ophthalmol. 0039-6257 19, 85-100 (1974).
    • (1974) Surv. Ophthalmol. , vol.19 , pp. 85-100
    • Lommatzsch, P.K.1
  • 2
    • 0022930989 scopus 로고
    • Beta irradiation of choroidal melanomas with Ru-106/Rh-106 applicators, 20 years experience
    • 0007-1161,. 10.1136/bjo.70.11.844
    • P. K. Lommatzsch, " Beta irradiation of choroidal melanomas with Ru-106/Rh-106 applicators, 20 years experience.," Br. J. Ophthamol. 0007-1161 70, 844-851 (1986). 10.1136/bjo.70.11.844
    • (1986) Br. J. Ophthamol. , vol.70 , pp. 844-851
    • Lommatzsch, P.K.1
  • 3
    • 0032888550 scopus 로고    scopus 로고
    • Strahlentherapie intraokularer tumoren
    • DOI 10.1007/s007610050439
    • W. Sauerwein and M. Zehetmayer, " Strahlentherapie intraokularer Tumoren.," Onkologie 0378-584X 5, 781-791 (1999). 10.1007/s007610050439 (Pubitemid 29470025)
    • (1999) Onkologe , vol.5 , Issue.9 , pp. 781-791
    • Sauerwein, W.1    Zehetmayer, M.2
  • 5
    • 22544444219 scopus 로고    scopus 로고
    • Plastic scintillation dosimetry: Optimal selection of scintillating fibers and scintillators
    • DOI 10.1118/1.1943807
    • L. Archambault, J. Arsenault, L. Gingras, A. S. Beddar, R. Roy, and L. Beaulieu, " Plastic scintillation dosimetry: Optimal selection of scintillating fibers and scintillators.," Med. Phys. 0094-2405 32, 2271-2278 (2005). 10.1118/1.1943807 (Pubitemid 41023185)
    • (2005) Medical Physics , vol.32 , Issue.7 , pp. 2271-2278
    • Archambault, L.1    Arsenault, J.2    Gingras, L.3    Beddar, A.S.4    Roy, R.5    Beaulieu, L.6
  • 6
    • 0343776958 scopus 로고    scopus 로고
    • A high-precision, high-resolution and fast dosimetry system for beta sources applied in cardiovascular brachytherapy
    • DOI 10.1118/1.598927
    • M. Bambynek, D. Flühs, U. Quast, D. Wegener, and C. G. Soares, " A high-precision, high-resolution and fast dosimetry system for beta sources applied in cardiovascular brachytherapy.," Med. Phys. 0094-2405 27, 662-667 (2000). 10.1118/1.598927 (Pubitemid 30227042)
    • (2000) Medical Physics , vol.27 , Issue.4 , pp. 662-667
    • Bambynek, M.1    Fluhs, D.2    Quast, U.3    Wegener, D.4    Soares, C.G.5
  • 7
    • 0026804696 scopus 로고
    • Water-equivalent plastic scintillation detectors for high-energy beam dosimetry. I. Physical characteristics and theoretical considerations
    • 0031-9155,. 10.1088/0031-9155/37/10/006
    • A. S. Beddar, T. R. Mackie, and F. H. Attix, " Water-equivalent plastic scintillation detectors for high-energy beam dosimetry. I. Physical characteristics and theoretical considerations.," Phys. Med. Biol. 0031-9155 37, 1883-1900 (1992). 10.1088/0031-9155/37/10/006
    • (1992) Phys. Med. Biol. , vol.37 , pp. 1883-1900
    • Beddar, A.S.1    MacKie, T.R.2    Attix, F.H.3
  • 8
    • 0026793771 scopus 로고
    • Water-equivalent plastic scintillation detectors for high-energy beam dosimetry. II. Properties and measurements
    • 0031-9155,. 10.1088/0031-9155/37/10/007
    • A. S. Beddar, T. R. Mackie, and F. H. Attix, " Water-equivalent plastic scintillation detectors for high-energy beam dosimetry. II. Properties and measurements.," Phys. Med. Biol. 0031-9155 37, 1901-1913 (1992). 10.1088/0031-9155/37/10/007
    • (1992) Phys. Med. Biol. , vol.37 , pp. 1901-1913
    • Beddar, A.S.1    MacKie, T.R.2    Attix, F.H.3
  • 9
    • 0038107451 scopus 로고    scopus 로고
    • Plastic scintillation dosimetry: Optimization of light collection efficiency
    • DOI 10.1088/0031-9155/48/9/305, PII S0031915503565459
    • A. S. Beddar, S. Law, N. Suchowerska, and T. R. Mackie, " Plastic scintillation dosimetry: Optimization of light collection efficiency.," Phys. Med. Biol. 0031-9155 48, 1141-1152 (2003). 10.1088/0031-9155/48/9/305 (Pubitemid 36621467)
    • (2003) Physics in Medicine and Biology , vol.48 , Issue.9 , pp. 1141-1152
    • Beddar, A.S.1    Law, S.2    Suchowerska, N.3    Mackie, T.R.4
  • 10
    • 0029867605 scopus 로고    scopus 로고
    • Direct reading measurement of absorbed dose with plastic scintillators - The general concept and applications to ophthalmic plaque dosimetry
    • DOI 10.1118/1.597736
    • D. Flühs, M. Heintz, F. Indenkämpen, C. Wieczorek, H. Kolanoski, and U. Quast, " Direct reading measurement of absorbed dose with plastic scintillators-The general concept and applications to ophthalmic plaque dosimetry.," Med. Phys. 0094-2405 23, 427-434 (1996). 10.1118/1.597736 (Pubitemid 26095699)
    • (1996) Medical Physics , vol.23 , Issue.3 , pp. 427-434
    • Fluhs, D.1    Heintz, M.2    Indenkampen, F.3    Wieczorek, C.4    Kolanoski, H.5    Quast, U.6
  • 11
    • 33751168473 scopus 로고    scopus 로고
    • A plastic scintillation dosimeter for high dose rate brachytherapy
    • DOI 10.1088/0031-9155/51/21/008, PII S0031915506261293, 008
    • J. Lambert, D. R. McKenzie, S. Law, J. Elsey, and N. Suchowerska, " A plastic scintillation dosimeter for high dose rate brachytherapy.," Phys. Med. Biol. 0031-9155 51, 5505-5516 (2006). 10.1088/0031-9155/51/21/008 (Pubitemid 44773328)
    • (2006) Physics in Medicine and Biology , vol.51 , Issue.21 , pp. 5505-5516
    • Lambert, J.1    McKenzie, D.R.2    Law, S.3    Elsey, J.4    Suchowerska, N.5
  • 12
    • 33748559875 scopus 로고
    • Wasser und gewebeäquivalente Festkörperphantome für hochenergetische Photonen und Elektronen
    • in "," in, edited by F. Nüsslin (DGMP, Tübingen)
    • D. Harder, A. Rubach, K. -P. Hermann, and A. Überschär, in " Wasser und gewebeäquivalente Festkörperphantome für hochenergetische Photonen und Elektronen.," in Medizinische Physik 1988, edited by, F. Nüsslin, (DGMP, Tübingen, 1989), pp. 325-330.
    • (1989) Medizinische Physik 1988 , pp. 325-330
    • Harder, D.1    Rubach, A.2    Hermann, K.-P.3    Überschär, A.4
  • 13
    • 0027169865 scopus 로고
    • Measurement of radial dose distributions around small beta-particle emitters using high-resolution radiochromic foil dosimetry
    • 0144-8420.
    • C. G. Soares and W. L. McLaughlin, " Measurement of radial dose distributions around small beta-particle emitters using high-resolution radiochromic foil dosimetry.," Radiat. Prot. Dosim. 0144-8420 47, 367-372 (1993).
    • (1993) Radiat. Prot. Dosim. , vol.47 , pp. 367-372
    • Soares, C.G.1    McLaughlin, W.L.2
  • 15
    • 70349665045 scopus 로고
    • edited by W. Beitz and K. -H. Küttner (Springer, Berlin),.
    • Dubbel Taschenbuch für Maschinenbau, edited by, W. Beitz, and, K. -H. Küttner, (Springer, Berlin, 1981), p. 14.
    • (1981) Dubbel Taschenbuch für Maschinenbau , pp. 14
  • 16
    • 1342330918 scopus 로고    scopus 로고
    • Dose backscatter factors for selected beta sources as a function of source, calcified plaque and contrast agent using Monte Carlo calculations
    • DOI 10.1088/0031-9155/49/4/009, PII S0031915504667856
    • S. W. Lee and W. D. Reece, " Dose backscatter factors for selected beta sources as a function of source, calcified plaque and contrast agent using Monte Carlo calculations.," Phys. Med. Biol. 0031-9155 49, 583-599 (2004). 10.1088/0031-9155/49/4/009 (Pubitemid 38255940)
    • (2004) Physics in Medicine and Biology , vol.49 , Issue.4 , pp. 583-599
    • Lee, S.-W.1    Reece, W.D.2
  • 17
    • 0038715481 scopus 로고    scopus 로고
    • A patch source model for treatment planning of ruthenium ophthalmic applicators
    • DOI 10.1118/1.1573971
    • M. A. Astrahan, " A patch source model for treatment planning of ruthenium ophthalmic applicators.," Med. Phys. 0094-2405 30, 1219-1228 (2003). 10.1118/1.1573971 (Pubitemid 36735988)
    • (2003) Medical Physics , vol.30 , Issue.6 , pp. 1219-1228
    • Astrahan, M.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.